1SDA072555R1 ABB E4.2S 4000 Ekip Touch LSI 3-Pole Air Circuit Breaker

1SDA072555R1 ABB E4.2S 4000 Ekip Touch LSI 3-Pole Air Circuit Breaker

ABB 1SDA072555R1 is a SACE Emax 2 E4.2S 4000 A three-pole withdrawable air circuit breaker moving part with an Ekip Touch LSI electronic trip unit for high-current low-voltage power distribution protection.

SKU: 1SDA072555R1MPN: 1SDA072555R1
Price
List Price £25,278.04 ex VAT
Your Price (ex VAT) Save 25%
£18,958.53 25% OFF
You save £6,319.51 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £18,958.53
Trade pricing is personalised to your account

Manufacturer Lead Time

£18,958.53

Why Choose the ABB 1SDA072555R1 E4.2S 4000 Ekip Touch LSI Air Circuit Breaker?

The ABB 1SDA072555R1 is a high-performance SACE Emax 2 E4.2S 4000 air circuit breaker moving part designed for protection and switching in demanding low-voltage electrical distribution systems. This three-pole configuration combines a 4000 A rated uninterrupted current with an advanced Ekip Touch LSI electronic trip unit, providing long-time, short-time and instantaneous protection.

As part of the ABB SACE Emax 2 range, the E4.2S combines high-current switching capability with electronic protection and a touchscreen-based Ekip interface. The Ekip Touch LSI release provides adjustable overload and short-circuit protection for applications requiring effective coordination and dependable protection of transformers, feeders and electrical installations.

This model is a 3-pole withdrawable moving part (WMP) rated at 4000 A and 690 V AC. The E4.2S performance level provides a rated ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC, together with a rated short-time withstand current of 66 kA for 1 s.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage power distribution.
  • 4000 A rated uninterrupted current for high-current industrial and infrastructure applications.
  • Ekip Touch LSI electronic trip unit with touchscreen-based configuration and monitoring.
  • LSI functionality provides long-time, short-time and instantaneous protection.
  • 85 kA Icu at 400–440 V AC for high-fault-level distribution systems.
  • 66 kA Icu at 500–690 V AC for higher-voltage low-voltage networks.
  • 66 kA short-time withstand current for 1 s supports protection coordination and selectivity.
  • Withdrawable moving-part design supports efficient switchboard servicing and maintenance.

Key Features

  • ABB SACE Emax 2 E4.2S frame.
  • 4000 A rated uninterrupted current.
  • 3-pole configuration.
  • Ekip Touch LSI solid-state electronic release.
  • Long-time L overload protection.
  • Short-time S delayed short-circuit protection.
  • Instantaneous I short-circuit protection.
  • 690 V AC rated operational voltage.
  • 85 kA Icu at 400–440 V AC.
  • 66 kA Icu at 500–690 V AC.
  • 66 kA Icw for 1 s and 3 s.
  • 4 auxiliary change-over contacts.
  • Circuit-breaker open/closed position indication.
  • Withdrawable moving part (WMP) configuration.

Advanced LSI Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 E4.2S provide switching and protection for high-current low-voltage distribution circuits. The Ekip Touch electronic trip unit monitors circuit conditions and initiates interruption when configured protection thresholds are exceeded, helping protect switchgear, conductors and connected equipment against overload and short-circuit currents.

The Ekip Touch LSI release combines adjustable long-time overload protection with short-time delayed and instantaneous short-circuit protection. Together with the E4.2S frame and withdrawable architecture, the 1SDA072555R1 provides a capable solution for installations where high-current protection, selective coordination, accessible electronic configuration and maintainability are important.

Typical Applications

  • Main incoming protection in high-current low-voltage switchboards.
  • Industrial power distribution systems.
  • Transformer protection and secondary distribution.
  • High-current feeder protection.
  • Commercial and infrastructure electrical distribution.
  • Power generation and utility distribution systems.
  • Power distribution centres and critical electrical installations.

Technical Specifications

Series SACE Emax 2
ABB order code 1SDA072555R1
EAN 8015644764050
Product type Air circuit breaker moving part
Frame E4.2S
Short-circuit performance level S
Rated current (In) 4000 A
Rated uninterrupted current (Iu) 4000 A
Number of poles 3
Trip unit Ekip Touch LSI
Release type Electronic
Protection functions L, S and I
Overload release current setting 1600–4000 A
Short-time delayed short-circuit setting 2400–40000 A
Instantaneous short-circuit setting 6000–60000 A
Integrated earth-fault protection No
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 400–440 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500–690 V AC 66 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw), 1 s 66 kA
Rated short-time withstand current (Icw), 3 s 66 kA
Electrical durability at ≤440 V 5000 cycles
Electrical durability at 500–690 V 4000 cycles
Mechanical durability 15,000 cycles
Power loss 900 W
Auxiliary contacts 4 change-over contacts
Motor drive Optional
Degree of protection IP30
Main-circuit connection Connection at separate chassis part
Configuration Withdrawable moving part (WMP)
Product net dimensions (W × H × D) 425 × 425 × 383 mm
Product net weight 60 kg
Standard IEC 60947-2
Product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA072555R1?

The ABB 1SDA072555R1 is a SACE Emax 2 E4.2S 4000 A three-pole withdrawable air circuit breaker moving part equipped with an Ekip Touch LSI electronic trip unit.

What is the rated current of the ABB E4.2S 1SDA072555R1?

The ABB 1SDA072555R1 has a rated uninterrupted current of 4000 A, making it suitable for demanding high-current low-voltage distribution systems.

What protection functions does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI provides L long-time overload, S short-time delayed short-circuit and I instantaneous short-circuit protection.

What are the protection setting ranges of the ABB 1SDA072555R1?

The overload release can be set from 1600–4000 A, the short-time delayed short-circuit release from 2400–40000 A, and the instantaneous short-circuit release from 6000–60000 A.

What is the breaking capacity of the ABB 1SDA072555R1?

The E4.2S has a rated ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC.

Does the ABB 1SDA072555R1 include ground-fault protection?

No. This model uses an Ekip Touch LSI release providing long-time, short-time and instantaneous protection; integrated earth-fault protection is not included in this configuration.

Is the ABB 1SDA072555R1 fixed or withdrawable?

This model is supplied as a withdrawable moving part (WMP) for connection through the appropriate separate SACE Emax 2 chassis part.

Where is the ABB E4.2S 4000 Ekip Touch LSI typically used?

It is suitable for demanding low-voltage distribution applications including main switchboards, industrial power systems, transformer protection, high-current feeders, infrastructure systems and critical electrical installations.

Trusted by Electrical Professionals Worldwide

ABB SACE Emax 2 air circuit breakers are designed for demanding low-voltage power distribution systems where dependable electronic protection, high short-circuit performance and maintainable switchgear architecture are required.