ABB 1SDA072547R1 Emax 2 E4.2N 4000 A three-pole withdrawable air circuit breaker moving part with Ekip G Touch LSIG electronic protection for generator and demanding low-voltage power distribution applications.
£19,616.33
The ABB E4.2N 4000 Ekip G Touch LSIG 3p WMP, order code 1SDA072547R1, is a high-performance SACE Emax 2 air circuit breaker moving part designed for generator protection and demanding low-voltage power distribution systems. As part of the advanced ABB SACE Emax 2 E4.2 series, this three-pole withdrawable breaker combines a 4000 A rated uninterrupted current with the sophisticated Ekip G Touch LSIG electronic trip unit.
The Ekip G Touch release is engineered for generator applications and provides LSIG protection against overloads, selective short circuits, instantaneous short circuits and earth faults. Its touchscreen interface simplifies configuration and monitoring, while integrated generator-specific protection and measurement capabilities make it suitable for critical generating sets and sophisticated electrical distribution networks.
The E4.2N performance level provides an ultimate short-circuit breaking capacity of 66 kA at 415 V AC and 66 kA at 690 V AC, together with a 66 kA short-time withstand current for 1 s. This WMP configuration is the withdrawable moving part of the breaker and is designed for installation with a compatible Emax 2 E4.2 fixed part.
ABB SACE Emax 2 air circuit breakers are designed to protect and control modern low-voltage electrical networks while providing the performance required for high-current installations. The E4.2N frame combines a 4000 A current rating with strong short-circuit withstand capability, making it well suited to generator switchboards, main distribution assemblies and other critical power systems.
The Ekip G Touch LSIG trip unit extends conventional circuit protection with functions specifically suited to generator applications. Its long-time, short-time, instantaneous and earth-fault protection functions safeguard generating equipment and distribution networks, while the touchscreen interface and integrated measurement capabilities support efficient configuration, diagnostics and system supervision.
| Series | SACE Emax 2 E4.2 |
|---|---|
| ABB order code | 1SDA072547R1 |
| Product type | Air circuit breaker moving part |
| Frame | E4.2 |
| Performance level | N |
| Rated uninterrupted current Iu | 4000 A |
| Rated operational voltage Ue | 690 V AC |
| Rated insulation voltage Ui | 1000 V AC |
| Rated impulse withstand voltage Uimp | 12 kV |
| Frequency | 50 / 60 Hz |
| Number of poles | 3 |
| Execution | Withdrawable moving part |
| Trip unit | Ekip G Touch |
| Protection functions | LSIG |
| Ultimate breaking capacity Icu at 400 / 415 V AC | 66 kA |
| Ultimate breaking capacity Icu at 690 V AC | 66 kA |
| Service breaking capacity Ics | 100% of Icu |
| Short-time withstand current Icw (1 s) | 66 kA |
| Short-time withstand current Icw (3 s) | 50 kA |
| Overload protection adjustment | 0.4–1 × In |
| Instantaneous short-circuit protection adjustment | 1.5–15 × In |
| Earth-fault protection adjustment | 0.1–1 × In |
| Earth-fault protection | Integrated |
| Standard | IEC 60947-2 |
| EAN | 8015644763978 |
| Product family | Emax 2 Air Circuit Breakers |
The ABB 1SDA072547R1 is a 4000 A three-pole withdrawable Emax 2 air circuit breaker moving part designed for generator protection and demanding low-voltage electrical distribution systems.
The breaker is fitted with an Ekip G Touch LSIG electronic trip unit, providing overload, selective short-circuit, instantaneous short-circuit and earth-fault protection together with generator-specific functionality.
The circuit breaker has a rated uninterrupted current of 4000 A.
The E4.2N provides an ultimate short-circuit breaking capacity of 66 kA at 415 V AC and 66 kA at 690 V AC.
This model is the withdrawable moving part of the Emax 2 circuit breaker system and is designed for installation with a compatible E4.2 fixed part.
ABB SACE Emax 2 air circuit breakers combine high-current performance, advanced electronic protection and generator-specific functionality, making them a dependable solution for power generation and demanding industrial, commercial and infrastructure distribution systems.