Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA072542R1 SACE Emax 2 E4.2N 4000 A three-pole withdrawable air circuit breaker moving part with an Ekip Dip LSI electronic release for selective high-current low-voltage AC distribution protection.
£16,678.27
The ABB 1SDA072542R1 is a high-current SACE Emax 2 E4.2N 4000 air circuit breaker moving part designed for protection and control of demanding low-voltage AC power distribution systems. Configured as an E4.2N 4000 Ekip Dip LSI 3p WMP, it combines a 4000 A rated current, three-pole construction and ABB's Ekip Dip solid-state electronic release with LSI protection functions.
As part of the ABB SACE Emax 2 air circuit breaker series, the E4.2N platform provides robust switching and fault protection for high-current industrial, commercial and infrastructure distribution systems. The N performance level delivers an ultimate short-circuit breaking capacity of 66 kA at 440 V AC together with a rated short-time withstand current of 66 kA for 1 s.
The Ekip Dip LSI electronic release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. Compared with an LI release, the additional short-time protection function provides greater flexibility for selective coordination between upstream and downstream protective devices. The three-pole withdrawable moving-part (WMP) construction is designed for use with the appropriate Emax 2 fixed part.
Air circuit breakers such as the ABB Emax 2 E4.2N protect high-current low-voltage networks against damaging overload and short-circuit conditions. With a 4000 A current rating, 66 kA ultimate breaking capacity at 440 V AC and 66 kA short-time withstand capability for 1 s, this E4.2N configuration is well suited to major distribution points in demanding electrical installations.
The Ekip Dip LSI release provides greater protection flexibility than a basic LI configuration. Long-time protection responds to sustained overloads, short-time protection allows a controlled delay for selective coordination with downstream protective devices, and instantaneous protection rapidly interrupts severe short circuits. This combination helps improve fault discrimination while maintaining robust protection of conductors and switchgear.
| Series | SACE Emax 2 |
|---|---|
| Frame | E4.2 |
| Performance level | N |
| Model / configuration | E4.2N 4000 Ekip Dip LSI 3p WMP |
| ABB order code | 1SDA072542R1 |
| Product type | Air circuit breaker moving part |
| Current type | AC |
| Rated current | 4000 A |
| Number of poles | 3 |
| Release | Ekip Dip LSI |
| Release type | Solid-state electronic |
| Protection functions | Long-time, short-time and instantaneous (LSI) |
| Long-time protection | L |
| Short-time protection | S |
| Instantaneous protection | I |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 66 kA |
| Rated short-time withstand current (Icw), 1 s | 66 kA |
| Auxiliary contacts | 4 |
| Position indication | Circuit breaker open / closed |
| Execution | Withdrawable moving part (WMP) |
| Product net width | 425 mm |
| Product net height | 425 mm |
| Product net depth | 383 mm |
| Product net weight | 60 kg |
| EAN | 8015644763923 |
| Customs tariff number | 85362090 |
| Product group | Emax2 Air Circuit Breaker |
The ABB 1SDA072542R1 is a SACE Emax 2 E4.2N 4000 three-pole withdrawable air circuit breaker moving part equipped with an Ekip Dip LSI solid-state electronic release.
The breaker has a rated current of 4000 A, making it suitable for high-current low-voltage AC power distribution applications.
The LSI configuration provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.
The E4.2N 4000 has an ultimate short-circuit breaking capacity of 66 kA at 440 V AC and a rated short-time withstand current of 66 kA for 1 s.
WMP identifies the withdrawable moving-part execution, designed for installation with the appropriate Emax 2 fixed part in a compatible withdrawable switchboard.
ABB SACE Emax 2 air circuit breakers combine robust short-circuit performance, selective electronic protection and flexible withdrawable architecture for dependable low-voltage power distribution in demanding industrial, commercial and infrastructure systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.