1SDA072458R1 ABB E4.2V 2000 Ekip Hi-Touch LSI 3P WMP Air Circuit Breaker

1SDA072458R1 ABB E4.2V 2000 Ekip Hi-Touch LSI 3P WMP Air Circuit Breaker

ABB 1SDA072458R1 SACE Emax 2 E4.2V 2000 A three-pole withdrawable air circuit breaker moving part with an Ekip Hi-Touch LSI electronic trip unit for advanced low-voltage power distribution protection.

SKU: 1SDA072458R1MPN: 1SDA072458R1
Price
List Price £17,131.38 ex VAT
Your Price (ex VAT) Save 25%
£12,848.54 25% OFF
You save £4,282.85 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £12,848.54
Trade pricing is personalised to your account

Manufacturer Lead Time

£12,848.54

Why Choose the ABB 1SDA072458R1 E4.2V 2000 Ekip Hi-Touch LSI Air Circuit Breaker?

The ABB 1SDA072458R1 is a high-performance Emax 2 E4.2V 2000 air circuit breaker moving part designed for advanced protection and control of demanding low-voltage power distribution systems. Configured as an E4.2V 2000 Ekip Hi-Touch LSI 3p WMP, it combines a 2000 A rated current, three-pole construction and ABB's advanced Ekip Hi-Touch electronic trip unit with LSI protection functions.

As part of the ABB SACE Emax 2 air circuit breaker series, the E4.2V platform is engineered for installations with high prospective fault currents and demanding requirements for protection, measurement and system integration. The V performance level provides very high short-circuit interruption capability, making the breaker suitable for critical industrial, commercial and infrastructure power-distribution applications.

The Ekip Hi-Touch LSI trip unit provides long-time overload, short-time selective short-circuit and instantaneous short-circuit protection together with advanced measurement, monitoring and protection capabilities. Its three-pole withdrawable moving-part (WMP) configuration is designed for use with the appropriate Emax 2 fixed part, enabling efficient isolation, inspection and servicing in compatible switchboards.

Key Advantages

  • High-performance ABB Emax 2 E4.2V air circuit breaker moving part.
  • 2000 A rated current for high-current low-voltage distribution.
  • Ekip Hi-Touch LSI electronic trip unit for advanced protection, measurement and monitoring.
  • LSI functionality provides long-time, short-time and instantaneous protection.
  • V performance level designed for networks with very high prospective short-circuit currents.
  • Three-pole construction for three-phase AC distribution systems.
  • Withdrawable moving-part execution supports switchboard maintainability and service continuity.
  • Emax 2 architecture supports integration into advanced electrical distribution and energy-management systems.

Key Features

  • ABB SACE Emax 2 E4.2 frame.
  • V high-breaking-capacity performance level.
  • 2000 A rated current.
  • Three-pole construction.
  • Ekip Hi-Touch LSI electronic trip unit.
  • Long-time (L) overload protection.
  • Short-time (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Advanced electrical measurement and protection functionality.
  • Touchscreen interface for settings, measurements and operating information.
  • Designed for low-voltage AC systems up to 690 V AC.
  • Withdrawable moving-part (WMP) execution for compatible Emax 2 switchgear.

Advanced Protection for Critical Low-Voltage Distribution

Air circuit breakers such as the ABB Emax 2 E4.2V protect high-current low-voltage networks against damaging overload and short-circuit conditions. The E4.2V platform combines substantial current-carrying capability with very high short-circuit performance, making it particularly suitable for main distribution positions and other critical points within electrical networks.

The Ekip Hi-Touch LSI trip unit enhances this protection with advanced electronic functionality. Long-time protection responds to sustained overloads, short-time protection supports selective coordination with downstream protective devices and instantaneous protection provides rapid interruption of severe short circuits. The Hi-Touch platform also provides extensive measurement and monitoring capabilities for sophisticated power-distribution applications.

Typical Applications

  • Main incoming protection in high-current low-voltage switchboards.
  • Industrial power distribution systems.
  • Large commercial building electrical distribution.
  • Data centres and critical-power installations.
  • Transformer secondary and feeder protection.
  • Generator and standby-power distribution.
  • Manufacturing and process-industry switchgear.
  • Infrastructure systems requiring advanced selective circuit protection.

Technical Specifications

Series SACE Emax 2
Frame E4.2
Performance level V
Model / configuration E4.2V 2000 Ekip Hi-Touch LSI 3p WMP
ABB order code 1SDA072458R1
Product type Air circuit breaker moving part
Current type AC
Rated current 2000 A
Rated uninterrupted current (Iu) 2000 A
Number of poles 3
Trip unit Ekip Hi-Touch
Protection configuration LSI
Release type Electronic
Long-time protection L
Short-time protection S
Instantaneous protection I
Rated operational voltage Up to 690 V AC
Execution Withdrawable moving part (WMP)
Product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA072458R1?

The ABB 1SDA072458R1 is a SACE Emax 2 E4.2V 2000 three-pole withdrawable air circuit breaker moving part equipped with an Ekip Hi-Touch LSI electronic trip unit.

What is the rated current of the ABB 1SDA072458R1?

The breaker has a rated current of 2000 A, making it suitable for high-current low-voltage power distribution systems.

What protection functions does the Ekip Hi-Touch LSI trip unit provide?

The LSI configuration provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What is the advantage of the Ekip Hi-Touch trip unit?

The Ekip Hi-Touch platform combines advanced electronic circuit protection with extensive electrical measurement, monitoring and configuration functionality for sophisticated power-distribution systems.

What does WMP mean on the ABB E4.2V 2000?

WMP identifies the withdrawable moving-part execution, designed for installation with the appropriate Emax 2 fixed part in a compatible withdrawable switchboard.

Trusted Protection for Critical Power Systems

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, sophisticated electronic protection and flexible withdrawable architecture for dependable operation in demanding industrial, commercial and infrastructure power systems.