ABB 1SDA072452R1 E4.2V 2000 Ekip Dip LSI 3p WMP is a three-pole 2000 A withdrawable SACE Emax 2 air circuit breaker moving part with Ekip Dip LSI electronic protection, 150 kA breaking capacity at 440 V AC and 100 kA short-time withstand capability for 1 second.
£9,603.53
The ABB E4.2V 2000 Ekip Dip LSI 3p WMP, order code 1SDA072452R1, is a high-performance SACE Emax 2 air circuit breaker designed for protection and switching in demanding low-voltage power distribution systems. This three-pole withdrawable moving part combines a 2000 A rated current with the reliable Ekip Dip LSI solid-state electronic protection release.
The Ekip Dip LSI release provides long-time, short-time and instantaneous protection, delivering comprehensive overload and short-circuit protection with the added selectivity of a short-time delayed protection function. This makes the breaker well suited to main distribution circuits where coordination with downstream protective devices is important.
With a rated operational voltage up to 690 V AC, an ultimate short-circuit breaking capacity of 150 kA at 440 V AC and a short-time withstand current of 100 kA for 1 s, the E4.2V 2000 is engineered for electrical systems with exceptionally high prospective fault currents. Its withdrawable construction facilitates inspection, maintenance and replacement within compatible ABB Emax 2 switchgear.
Air circuit breakers such as the ABB Emax 2 E4.2V protect low-voltage electrical systems by interrupting excessive current during overload and short-circuit conditions. The E4.2V performance level is engineered for installations with very high prospective fault currents, combining exceptional breaking capacity with strong short-time withstand performance.
The Ekip Dip LSI release adds short-time delayed protection to the long-time and instantaneous functions, enabling improved coordination between upstream and downstream protective devices. Combined with the withdrawable Emax 2 architecture, it provides a robust solution for critical switchboards where selectivity, high fault-clearing capability, operational continuity and efficient servicing are important.
| Series | SACE Emax 2 |
|---|---|
| Order code | 1SDA072452R1 |
| Product type | Air circuit breaker moving part |
| Frame | E4.2 |
| Performance level | V |
| Rated current | 2000 A |
| Rated uninterrupted current (Iu) | 2000 A |
| Number of poles | 3 |
| Current type | AC |
| Protection release | Ekip Dip LSI |
| Release type | Solid-state electronic |
| Protection functions | Long-time, short-time and instantaneous (LSI) |
| Short-time delayed short-circuit release setting | From 1200 A |
| Instantaneous short-circuit release setting | From 3000 A |
| Integrated earth-fault protection | No |
| Rated operational voltage | Up to 690 V AC |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 150 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 150 kA |
| Short-time withstand current (Icw) | 100 kA for 1 s |
| Construction | Withdrawable moving part |
| Main circuit connection | Connection at separate chassis / fixed part |
| Auxiliary contacts | 4 change-over contacts |
| Switched-off indication | Yes |
| Control element | Push button |
| Motor operator | Optional |
| Integrated motor operator | No |
| Protection rating | IP30 |
| Product net weight | 60 kg |
| Standard | IEC 60947-2 |
The ABB 1SDA072452R1 is a 2000 A Emax 2 air circuit breaker moving part designed for switching and protecting demanding low-voltage power distribution systems with high prospective fault currents.
This breaker uses the ABB Ekip Dip LSI solid-state electronic release, providing long-time, short-time and instantaneous protection.
The E4.2V 2000 has an ultimate short-circuit breaking capacity of 150 kA at 440 V AC and a short-time withstand current of 100 kA for 1 second.
The 1SDA072452R1 is the moving part of a withdrawable Emax 2 air circuit breaker and connects through the appropriate separate fixed part or chassis.
LSI denotes long-time, short-time and instantaneous protection, providing overload protection together with delayed and instantaneous short-circuit protection for improved system coordination.
ABB SACE Emax 2 air circuit breakers combine exceptional fault-breaking performance, dependable electronic protection and flexible switchgear integration for demanding industrial, infrastructure and high-power distribution systems.