1SDA072451R1 ABB E4.2V 2000 Ekip Dip LI 3p WMP Air Circuit Breaker

1SDA072451R1 ABB E4.2V 2000 Ekip Dip LI 3p WMP Air Circuit Breaker

ABB 1SDA072451R1 E4.2V 2000 Ekip Dip LI 3p WMP is a three-pole 2000 A withdrawable SACE Emax 2 air circuit breaker moving part with Ekip Dip LI electronic protection, 150 kA breaking capacity at 415–440 V AC and 100 kA short-time withstand capability for 1 second.

SKU: 1SDA072451R1MPN: 1SDA072451R1
Price
List Price £12,297.99 ex VAT
Your Price (ex VAT) Save 25%
£9,223.49 25% OFF
You save £3,074.50 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,223.49
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,223.49

Why Choose the ABB E4.2V 2000 Ekip Dip LI 3p WMP Air Circuit Breaker?

The ABB E4.2V 2000 Ekip Dip LI 3p WMP, order code 1SDA072451R1, is a high-performance SACE Emax 2 air circuit breaker designed for protection and switching in demanding low-voltage power distribution systems. This three-pole withdrawable moving part combines a 2000 A rated current with the reliable Ekip Dip LI solid-state electronic protection release.

The Ekip Dip LI release provides long-time overload and instantaneous short-circuit protection, delivering straightforward electronic protection for main distribution circuits. Its adjustable protection functions allow the breaker to be coordinated with installation requirements while retaining the simplicity and reliability of ABB's Ekip Dip platform.

With an ultimate short-circuit breaking capacity of 150 kA at 415–440 V AC and 100 kA at 690 V AC, together with a short-time withstand current of 100 kA for 1 s, the E4.2V 2000 is engineered for electrical systems with exceptionally high prospective fault currents. Its withdrawable construction facilitates inspection, maintenance and replacement within compatible ABB Emax 2 switchgear.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage distribution.
  • 2000 A rated current for high-current industrial and infrastructure applications.
  • Ekip Dip LI electronic release provides long-time overload and instantaneous short-circuit protection.
  • Exceptional 150 kA breaking capacity at 415–440 V AC.
  • 100 kA breaking capacity at 690 V AC for demanding higher-voltage LV systems.
  • 100 kA short-time withstand current for 1 s supports high levels of selectivity.
  • Withdrawable three-pole construction supports efficient maintenance and switchgear servicing.

Key Features

  • ABB SACE Emax 2 E4.2V air circuit breaker moving part.
  • 2000 A rated uninterrupted current.
  • Three-pole configuration for three-phase AC systems.
  • Ekip Dip LI solid-state electronic protection release.
  • Long-time overload and instantaneous short-circuit protection functions.
  • 150 kA Icu at 415–440 V AC.
  • 100 kA Icu at 690 V AC.
  • 100 kA Icw for 1 s.
  • Withdrawable moving-part construction for compatible Emax 2 switchgear.
  • Four auxiliary contacts for signalling and control.
  • Circuit-breaker open/closed position indication.
  • S51 trip signalling contact supplied as standard.

High-Fault-Level Protection for Critical Power Distribution

Air circuit breakers such as the ABB Emax 2 E4.2V protect low-voltage electrical systems by interrupting excessive current during overload and short-circuit conditions. The E4.2V performance level is designed for installations with very high prospective fault currents, combining a high breaking capacity with strong short-time withstand performance to support selective distribution architectures.

The Ekip Dip LI release provides dependable electronic long-time and instantaneous protection without unnecessary complexity. Combined with the withdrawable Emax 2 architecture, the E4.2V provides a robust solution for critical switchboards where high fault-clearing capability, operational continuity and efficient servicing are essential.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems with high prospective fault currents.
  • Critical infrastructure electrical installations.
  • Manufacturing and process plant switchgear.
  • Transformer incomers and high-power distribution circuits.
  • High-current three-phase systems requiring exceptional short-circuit breaking performance.

Technical Specifications

Series SACE Emax 2
Order code 1SDA072451R1
EAN 8015644763015
Product type Air circuit breaker moving part
Frame E4.2
Performance level V
Rated current 2000 A
Rated uninterrupted current (Iu) 2000 A
Number of poles 3
Current type AC
Protection release Ekip Dip LI
Release type Solid-state electronic
Protection functions Long-time and instantaneous (LI)
Ultimate short-circuit breaking capacity (Icu) at 415–440 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 100 kA
Short-time withstand current (Icw) 100 kA for 1 s
Construction Withdrawable moving part
Fixed part Ordered separately
Auxiliary contacts 4 auxiliary contacts
Trip signalling contact S51
Position indication Circuit breaker open / closed
Product net width 425 mm
Product net height 425 mm
Product net depth 383 mm
Product net weight 60 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA072451R1 used for?

The ABB 1SDA072451R1 is a 2000 A Emax 2 air circuit breaker moving part designed for switching and protecting demanding low-voltage AC power distribution systems with high prospective fault currents.

What protection release does this breaker use?

This breaker uses the ABB Ekip Dip LI solid-state electronic release, providing long-time overload and instantaneous short-circuit protection.

What is the breaking capacity of the E4.2V 2000?

The E4.2V 2000 provides an ultimate short-circuit breaking capacity of 150 kA at 415–440 V AC and 100 kA at 690 V AC, with a short-time withstand current of 100 kA for 1 second.

Is the ABB 1SDA072451R1 fixed or withdrawable?

The 1SDA072451R1 is the moving part of a withdrawable Emax 2 air circuit breaker. The compatible fixed part or chassis is ordered separately.

What does LI protection mean?

LI denotes long-time and instantaneous protection, providing overload protection together with instantaneous protection against high short-circuit currents.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers combine exceptional fault-breaking performance, dependable electronic protection and flexible switchgear integration for demanding industrial, infrastructure and high-power distribution systems.