ABB 1SDA072417R1 E2.2N 2500 Ekip G Touch LSIG 3p WMP is a three-pole 2500 A withdrawable SACE Emax 2 air circuit breaker moving part with generator-oriented LSIG electronic protection and 66 kA short-circuit breaking capacity up to 690 V AC.
£11,313.75
The ABB E2.2N 2500 Ekip G Touch LSIG 3p WMP, order code 1SDA072417R1, is a high-performance SACE Emax 2 air circuit breaker designed for protection, switching and power management in demanding low-voltage electrical systems. Part of the ABB Emax 2 E2.2 series, this three-pole withdrawable moving part combines a 2500 A rated current with the advanced Ekip G Touch LSIG electronic protection release.
Designed for power distribution and generator applications, the Ekip G Touch LSIG release provides long-time, short-time, instantaneous and ground-fault protection together with generator-specific protection functions and integrated Ekip Measuring Pro capabilities. Its touch-sensitive display provides convenient configuration and supervision of protection functions for sophisticated electrical installations.
With a rated operational voltage of 690 V AC and an ultimate short-circuit breaking capacity of 66 kA from 380–690 V AC, the E2.2N 2500 provides dependable fault interruption across a wide operating-voltage range. Its withdrawable moving-part construction and rear-terminal arrangement support efficient servicing and integration within compatible ABB Emax 2 switchgear.
Air circuit breakers such as the ABB Emax 2 E2.2N protect low-voltage electrical systems by interrupting excessive current during overload, short-circuit and earth-fault conditions. The E2.2N platform combines high current-carrying capability with consistent short-circuit breaking performance for important main and distribution circuits.
The Ekip G Touch LSIG release extends these capabilities with generator-specific protection, advanced measurement and an intuitive touch interface. Combined with the withdrawable Emax 2 architecture, it provides a flexible solution for switchboards requiring comprehensive protection, system monitoring, operational continuity and efficient maintenance.
| Series | SACE Emax 2 |
|---|---|
| Order code | 1SDA072417R1 |
| EAN | 8015644762674 |
| Product type | Air circuit breaker moving part |
| Frame | E2.2 |
| Performance level | N |
| Rated current | 2500 A |
| Number of poles | 3 |
| Current type | AC |
| Protection release | Ekip G Touch LSIG |
| Release type | Solid-state electronic |
| Protection functions | Long-time, short-time, instantaneous and ground-fault (LSIG) |
| Overload protection adjustment | 0.4–1 × In |
| Short-time protection adjustment | 0.6–10 × In |
| Instantaneous protection adjustment | 1.5–15 × In |
| Ground-fault protection adjustment | 0.1–1 × In |
| Generator-specific protection | Integrated |
| Measurement module | Ekip Measuring Pro integrated |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Frequency | 50 / 60 Hz |
| Ultimate short-circuit breaking capacity (Icu) at 380 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 400–415 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500–525 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 66 kA |
| Construction | Withdrawable moving part |
| Terminal arrangement | Rear terminals |
| Auxiliary contacts | 4 auxiliary contacts |
| Position indication | Circuit breaker open / closed |
| Product net weight | 48 kg |
| Standard | IEC 60947-2 |
The ABB 1SDA072417R1 is a 2500 A Emax 2 air circuit breaker moving part designed for advanced protection and switching in low-voltage power distribution and generator systems.
This breaker uses the ABB Ekip G Touch LSIG electronic release, providing long-time, short-time, instantaneous and ground-fault protection together with generator-specific protection functions.
The E2.2N 2500 has an ultimate short-circuit breaking capacity of 66 kA from 380–690 V AC, including at 400–415 V, 440 V, 500–525 V and 690 V AC.
The 1SDA072417R1 is the moving part of a withdrawable Emax 2 air circuit breaker, designed for installation with the appropriate compatible fixed part or chassis.
Yes. The Ekip G Touch LSIG release incorporates generator-specific protection functions together with LSIG protection and integrated Ekip Measuring Pro measurement capabilities.
ABB SACE Emax 2 air circuit breakers combine dependable fault-breaking performance, advanced electronic protection and generator-oriented functionality for demanding industrial, infrastructure and power-generation systems.