1SDA072395R1 ABB E2.2S 2000 Ekip Touch LSI 3p WMP Air Circuit Breaker

1SDA072395R1 ABB E2.2S 2000 Ekip Touch LSI 3p WMP Air Circuit Breaker

ABB 1SDA072395R1 Emax 2 E2.2S 2000 is a 2000 A three-pole withdrawable air circuit breaker with Ekip Touch LSI electronic protection, an 85 kA breaking capacity at 440 V AC and a 66 kA short-time withstand current for 1 s.

SKU: 1SDA072395R1MPN: 1SDA072395R1
Price
List Price £10,212.57 ex VAT
Your Price (ex VAT) Save 25%
£7,659.43 25% OFF
You save £2,553.14 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,659.43
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,659.43

Why Choose the ABB E2.2S 2000 Ekip Touch LSI 3p WMP Air Circuit Breaker?

The ABB E2.2S 2000 Ekip Touch LSI 3p WMP, order code 1SDA072395R1, is a high-performance air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for reliable protection and control of demanding low-voltage electrical distribution systems. Combining the E2.2S frame with a 2000 A rated uninterrupted current and Ekip Touch LSI electronic trip unit, it provides advanced overload and short-circuit protection for industrial, commercial and infrastructure power networks.

The Ekip Touch LSI electronic trip unit provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. Its touchscreen interface supports convenient configuration and access to operating information, while the short-time protection function enables selective coordination between upstream and downstream protective devices.

The E2.2S performance level provides a rated ultimate short-circuit breaking capacity of 85 kA at 440 V AC together with a rated short-time withstand current of 66 kA for 1 s. This three-pole WMP configuration is supplied as a withdrawable moving part, supporting efficient inspection, servicing and replacement within compatible ABB Emax 2 withdrawable switchgear assemblies.

Key Advantages

  • High-performance 2000 A Emax 2 air circuit breaker for demanding low-voltage power distribution.
  • 85 kA ultimate short-circuit breaking capacity at 440 V AC for installations with high prospective fault currents.
  • 66 kA short-time withstand current for 1 s supports selective protection strategies.
  • Ekip Touch LSI electronic trip unit provides long-time, short-time and instantaneous protection.
  • Touchscreen interface supports straightforward protection configuration and access to operating information.
  • Withdrawable moving-part construction supports efficient inspection, maintenance and breaker replacement.

Key Features

  • ABB SACE Emax 2 E2.2S series.
  • 2000 A rated uninterrupted current.
  • Three-pole configuration.
  • 85 kA Icu at 440 V AC.
  • 66 kA Icw for 1 s.
  • Ekip Touch LSI electronic trip unit.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • Overload protection setting range of 800–2000 A.
  • Instantaneous short-circuit setting range of 3000–30000 A.
  • No integrated earth-fault protection in this LSI configuration.
  • Touch interface for protection configuration and operating information.
  • Withdrawable moving-part configuration for compatible Emax 2 switchgear.

Selective LSI Protection for High-Current Power Distribution

ABB SACE Emax 2 air circuit breakers are engineered for the protection and control of low-voltage electrical networks where high current capacity, dependable fault interruption and selective coordination are required. The E2.2S performance level combines a 2000 A current rating with substantial short-circuit breaking and withstand capability, making this breaker suitable for main distribution boards, industrial switchgear and critical power-distribution installations.

The Ekip Touch LSI trip unit combines long-time overload protection with short-time delayed and instantaneous short-circuit protection. The short-time function supports selective coordination by allowing downstream protective devices an opportunity to clear local faults before an upstream breaker operates, while instantaneous protection provides rapid interruption of severe short-circuit conditions.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Main incoming electrical supplies.
  • Manufacturing and process plants.
  • Commercial building electrical distribution.
  • Infrastructure and utility installations.
  • Electrical systems requiring high-current selective LSI protection.

Technical Specifications

Product range SACE Emax 2
ABB product group Emax2 Air Circuit Breaker
Frame E2.2S
Order code / MPN 1SDA072395R1
EAN 8015644762452
Product type Air circuit breaker
Rated uninterrupted current (Iu) 2000 A
Number of poles 3
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Rated short-time withstand current (Icw) 66 kA for 1 s
Performance level S
Trip unit Ekip Touch LSI
Release type Electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Overload protection setting range 800–2000 A
Instantaneous short-circuit setting range 3000–30000 A
Earth-fault protection Not included in the LSI configuration
Installation Withdrawable
Configuration Moving part (WMP)
Product net weight 53 kg
Country of origin Italy
Reference standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA072395R1 used for?

The ABB 1SDA072395R1 is a 2000 A three-pole air circuit breaker designed to protect and control demanding low-voltage electrical distribution systems where high current capacity and selective LSI protection are required.

What is the current rating of the ABB E2.2S 2000?

The ABB E2.2S 2000 has a rated uninterrupted current of 2000 A.

What is the breaking capacity of the ABB 1SDA072395R1?

The E2.2S performance level provides a rated ultimate short-circuit breaking capacity of 85 kA at 440 V AC and a rated short-time withstand current of 66 kA for 1 s.

What protection does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI electronic trip unit provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. This LSI configuration does not include integrated earth-fault protection.

Is the ABB 1SDA072395R1 fixed or withdrawable?

The 1SDA072395R1 is supplied as a withdrawable moving part (WMP) for installation within a compatible ABB Emax 2 withdrawable circuit-breaker assembly.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine dependable electrical protection, advanced electronic trip technology and service-friendly withdrawable construction for demanding industrial, commercial and infrastructure power-distribution systems.