ABB 1SDA072379R1 Emax 2 E2.2B 2000 is a 2000 A three-pole withdrawable air circuit breaker with Ekip Hi-Touch LSIG electronic protection, integrated measurement and a 42 kA breaking capacity at up to 690 V AC for advanced low-voltage power distribution systems.
£9,471.98
The ABB E2.2B 2000 Ekip Hi-Touch LSIG 3p WMP, order code 1SDA072379R1, is an advanced air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for comprehensive protection, measurement and management of low-voltage electrical distribution systems. Combining the E2.2B frame with a 2000 A rated uninterrupted current and Ekip Hi-Touch LSIG electronic trip unit, it provides sophisticated protection for industrial, commercial and infrastructure power networks.
The Ekip Hi-Touch LSIG electronic trip unit provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection. Its advanced touchscreen platform incorporates extensive electrical measurement and network-analysis capabilities, making the breaker particularly suitable for installations requiring detailed monitoring alongside selective circuit protection.
The E2.2B performance level delivers a rated ultimate short-circuit breaking capacity of 42 kA at 380–690 V AC. This three-pole WMP configuration is supplied as a withdrawable moving part, allowing convenient inspection, servicing and replacement within compatible ABB Emax 2 withdrawable switchgear assemblies.
ABB SACE Emax 2 air circuit breakers combine dependable circuit protection with advanced measurement, monitoring and power-management capabilities. The E2.2B frame provides a high-current solution for low-voltage systems, while the Ekip Hi-Touch platform makes this configuration particularly suitable for installations requiring detailed electrical supervision, selective protection and enhanced visibility of network conditions.
The Ekip Hi-Touch LSIG trip unit combines long-time overload protection with short-time delayed, instantaneous and earth-fault protection. Integrated measurement and network-analysis functionality complements these protective functions, allowing the breaker to serve as both a protection device and a valuable source of electrical-system information within sophisticated power-distribution installations.
| Product range | SACE Emax 2 |
|---|---|
| ABB product group | Emax2 Air Circuit Breaker |
| Frame | E2.2B |
| Order code / MPN | 1SDA072379R1 |
| Product type | Air circuit breaker |
| Rated uninterrupted current | 2000 A |
| Number of poles | 3 |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Frequency | 50/60 Hz |
| Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 42 kA |
| Performance level | B |
| Trip unit | Ekip Hi-Touch LSIG |
| Release type | Electronic |
| Protection functions | Long-time, short-time, instantaneous and earth fault (LSIG) |
| Overload protection adjustment | 0.4–1 × In |
| Short-time selective protection adjustment | 0.6–10 × In |
| Instantaneous protection adjustment | 1.5–15 × In |
| Earth-fault protection adjustment | 0.1–1 × In |
| Integrated earth-fault protection | Yes |
| Measurement | Ekip Measuring Pro |
| Network analysis | Integrated Network Analyzer |
| User interface | Touch-sensitive display |
| Installation | Withdrawable |
| Configuration | Moving part (WMP) |
| Reference standard | IEC 60947-2 |
The ABB 1SDA072379R1 is a 2000 A three-pole air circuit breaker designed to protect, monitor and control demanding low-voltage electrical distribution systems requiring comprehensive LSIG protection and advanced electrical measurement.
The ABB E2.2B 2000 has a rated uninterrupted current of 2000 A.
The E2.2B performance level provides a rated ultimate short-circuit breaking capacity of 42 kA at 380, 400/415, 440, 500/525 and 690 V AC.
The Ekip Hi-Touch LSIG electronic trip unit provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection, together with advanced measurement and network-analysis capabilities.
The 1SDA072379R1 is supplied as a withdrawable moving part (WMP) for installation within a compatible ABB Emax 2 withdrawable circuit-breaker assembly.
ABB SACE Emax 2 air circuit breakers combine dependable electrical protection, advanced electronic trip technology, integrated measurement and power-system monitoring capabilities for demanding industrial, commercial and infrastructure power-distribution systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.