ABB 1SDA072374R1 SACE Emax 2 E2.2B 2000 A three-pole withdrawable air circuit breaker moving part with Ekip Touch LI electronic overload and instantaneous short-circuit protection.
£6,212.34
The ABB E2.2B 2000 Ekip Touch LI 3p WMP, order code 1SDA072374R1, is a SACE Emax 2 air circuit breaker moving part designed for high-current low-voltage AC power distribution. This three-pole E2.2B configuration has a rated current of 2000 A and is equipped with ABB's Ekip Touch LI solid-state electronic protection release.
The Ekip Touch LI release provides long-time overload and instantaneous short-circuit protection, combining configurable electronic protection with a touchscreen interface for setting and supervision. The LI configuration is suited to applications where overload protection and rapid interruption of high-level short circuits are required without the short-time delayed or earth-fault functions of LSI and LSIG releases.
This product is supplied as a withdrawable moving part (WMP) for use with the corresponding SACE Emax 2 fixed part. The E2.2B 2000 platform provides a rated ultimate short-circuit breaking capacity of 42 kA at 440 V AC and a rated short-time withstand current of 42 kA for 1 s, while four auxiliary contacts and open/closed breaker indication support switchboard signalling and control.
The ABB SACE Emax 2 E2.2B provides electronic protection for high-current low-voltage distribution circuits where overload and instantaneous short-circuit protection are required. Its Ekip Touch LI release combines the long-time function for overload protection with instantaneous tripping for severe short-circuit faults, while the touchscreen interface provides convenient access to protection configuration and operating information.
The withdrawable construction supports maintainable switchboard designs by allowing the breaker moving part to be separated from its compatible fixed part for inspection, servicing or replacement. Combined with four auxiliary contacts and open/closed position indication, the E2.2B 2000 is well suited to industrial and infrastructure distribution systems requiring dependable high-current switching and straightforward electronic protection.
| Series | SACE Emax 2 E2.2 |
|---|---|
| ABB order code | 1SDA072374R1 |
| Product group | Emax2 Air Circuit Breaker |
| Product type | Air circuit breaker moving part |
| Performance level | B |
| Version | Withdrawable moving part (WMP) |
| Number of poles | 3 |
| Rated current | 2000 A |
| Current type | AC |
| Rated ultimate short-circuit breaking capacity Icu at 440 V AC | 42 kA |
| Rated short-time withstand current Icw (1 s) | 42 kA |
| Protection release | Ekip Touch LI |
| Release technology | Solid-state electronic |
| Protection functions | Long-time overload (L) and instantaneous short circuit (I) |
| Integrated earth-fault protection | No |
| Short-time delayed protection | No |
| User interface | Touchscreen |
| Auxiliary contacts | 4 |
| Breaker indication | Open / closed |
| Main-circuit connection | Via corresponding fixed part |
| Product net width | 317 mm |
| Product net height | 425 mm |
| Product net depth | 383 mm |
| Product net weight | 48 kg |
| EAN | 8015644762247 |
The ABB 1SDA072374R1 is a SACE Emax 2 E2.2B 2000 A three-pole withdrawable air circuit breaker moving part equipped with an Ekip Touch LI solid-state electronic protection release.
The Ekip Touch LI release provides long-time overload and instantaneous short-circuit protection. This LI configuration does not include the short-time delayed or integrated earth-fault functions provided by LSI and LSIG releases.
The ABB E2.2B 1SDA072374R1 has a rated current of 2000 A, making it suitable for high-current industrial, commercial and infrastructure distribution circuits.
The E2.2B 2000 provides a rated ultimate short-circuit breaking capacity of 42 kA at 440 V AC and a rated short-time withstand current of 42 kA for 1 s.
This product is a withdrawable moving part (WMP) designed for use with the corresponding ABB SACE Emax 2 fixed part to form a complete withdrawable air circuit breaker installation.
ABB SACE Emax 2 air circuit breakers combine high-current switching, configurable electronic protection and service-friendly withdrawable construction to provide dependable circuit protection for demanding industrial, commercial and infrastructure power-distribution systems.