1SDA072360R1 ABB E2.2S 1600 Ekip G Hi-Touch LSIG 3p WMP Air Circuit Breaker

1SDA072360R1 ABB E2.2S 1600 Ekip G Hi-Touch LSIG 3p WMP Air Circuit Breaker

ABB 1SDA072360R1 SACE Emax 2 E2.2S 1600 A three-pole withdrawable air circuit breaker moving part with Ekip G Hi-Touch LSIG electronic protection for generator and advanced power-distribution applications.

SKU: 1SDA072360R1MPN: 1SDA072360R1
Price
List Price £12,434.42 ex VAT
Your Price (ex VAT) Save 25%
£9,325.82 25% OFF
You save £3,108.61 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,325.82
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,325.82

Why Choose the ABB E2.2S 1600 Ekip G Hi-Touch LSIG 3p WMP Air Circuit Breaker?

The ABB E2.2S 1600 Ekip G Hi-Touch LSIG 3p WMP, order code 1SDA072360R1, is a high-performance SACE Emax 2 air circuit breaker moving part designed for advanced protection, switching and power management in demanding low-voltage power-distribution and generator applications. This three-pole E2.2S model combines a rated uninterrupted current of 1600 A with ABB's advanced Ekip G Hi-Touch LSIG electronic protection release.

The Ekip G Hi-Touch LSIG release combines generator-oriented functionality with long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection. The Hi-Touch platform also supports advanced electrical measurement, monitoring and network-analysis capabilities, making this configuration particularly suitable for sophisticated generation, critical-power and industrial distribution systems.

This version is supplied as a withdrawable moving part (WMP) for use with the corresponding SACE Emax 2 fixed part. The E2.2S performance level provides an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC, together with a rated short-time withstand current of 66 kA for 1 s.

Key Advantages

  • High-performance ABB SACE Emax 2 E2.2S air circuit breaker platform.
  • 1600 A rated uninterrupted current for high-current power systems.
  • Three-pole configuration for three-phase AC networks.
  • Ekip G Hi-Touch LSIG electronic release with generator-oriented protection and advanced power-management functionality.
  • Long-time, short-time delayed, instantaneous and earth-fault protection functions.
  • 85 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 66 kA short-time withstand current for 1 s supports selective protection strategies.
  • Advanced measurement and network-analysis capabilities support detailed electrical-system supervision.
  • Withdrawable construction facilitates inspection, servicing and replacement of the breaker moving part.
  • Suitable for IT networks up to 690 V.

Key Features

  • ABB SACE Emax 2 E2.2S series.
  • 1600 A rated uninterrupted current.
  • 3-pole circuit-breaker configuration.
  • Ekip G Hi-Touch LSIG electronic protection release.
  • Generator-oriented Ekip G protection platform.
  • Long-time overload protection (L).
  • Short-time delayed short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Integrated earth-fault protection (G).
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 85 kA Icu at 400–440 V AC.
  • 66 kA Icu at 500–690 V AC.
  • 66 kA Icw for 1 s.
  • 50 kA Icw for 3 s.
  • Withdrawable moving part (WMP) construction.
  • Advanced Hi-Touch monitoring and network-analysis functionality.

Advanced Generator and High-Current Power Protection

The ABB SACE Emax 2 E2.2S provides comprehensive protection for high-current low-voltage power systems. Its Ekip G Hi-Touch LSIG release combines long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection with generator-oriented functionality, helping coordinate protection across generation equipment and downstream distribution networks.

The E2.2S frame combines strong short-circuit breaking and withstand performance with the maintainability of a withdrawable design. The moving part can be separated from its compatible fixed part for inspection, servicing or replacement, while the advanced Hi-Touch platform supports detailed monitoring and network analysis for critical industrial, infrastructure and power-generation installations.

Typical Applications

  • Generator protection and generator switchboards.
  • Industrial low-voltage power distribution systems.
  • Main incomer and high-current feeder protection.
  • Standby and emergency power-generation systems.
  • Manufacturing and process-industry electrical networks.
  • Data centres and critical power infrastructure.
  • Commercial and infrastructure distribution switchboards.
  • Three-phase AC networks requiring comprehensive LSIG protection.
  • Systems requiring advanced electrical measurement and network analysis.
  • Withdrawable switchgear requiring generator-oriented electronic protection.

Technical Specifications

Series SACE Emax 2 E2.2
ABB order code 1SDA072360R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker moving part
Performance level S
Version Withdrawable moving part (WMP)
Number of poles 3
Rated current In 1600 A
Rated uninterrupted current Iu 1600 A
Current type AC
Rated operational voltage 690 V AC
Rated insulation voltage Ui 1000 V AC
Rated impulse withstand voltage Uimp 12 kV
Icu at 400 V AC 85 kA
Icu at 415 V AC 85 kA
Icu at 440 V AC 85 kA
Icu at 500 V AC 66 kA
Icu at 525 V AC 66 kA
Icu at 690 V AC 66 kA
Rated service short-circuit breaking capacity Ics 100% of Icu
Rated short-time withstand current Icw (1 s) 66 kA
Rated short-time withstand current Icw (3 s) 50 kA
Protection release Ekip G Hi-Touch LSIG
Release type Electronic
Protection functions Long-time overload (L), short-time delayed short circuit (S), instantaneous short circuit (I) and earth fault (G)
Integrated earth-fault protection Yes
Generator-oriented protection Ekip G platform
Connecting capacity 1200 mm²
Electrical durability at Ue ≤ 440 V 12,000 operating cycles
Electrical durability at Ue 500–690 V 10,000 operating cycles
Maximum electrical operating frequency 30 cycles per hour
Mechanical durability 25,000 operating cycles
Maximum mechanical operating frequency 60 cycles per hour
Power loss 288 W
Suitable for IT networks Yes, up to 690 V
Standard IEC
EAN 8015644762100

Frequently Asked Questions

What is the ABB 1SDA072360R1?

The ABB 1SDA072360R1 is a SACE Emax 2 E2.2S 1600 A three-pole withdrawable air circuit breaker moving part equipped with an Ekip G Hi-Touch LSIG electronic protection release.

What protection functions does the Ekip G Hi-Touch LSIG release provide?

The Ekip G Hi-Touch LSIG release provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and integrated earth-fault protection, together with advanced generator-oriented protection, monitoring and network-analysis functionality.

What is the rated current of the ABB E2.2S 1SDA072360R1?

The ABB E2.2S 1SDA072360R1 has a rated uninterrupted current of 1600 A, making it suitable for substantial industrial, infrastructure, generator and critical-power distribution systems.

What is the short-circuit performance of the E2.2S 1600?

The E2.2S 1600 provides an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC, together with short-time withstand ratings of 66 kA for 1 s and 50 kA for 3 s.

Is the ABB 1SDA072360R1 a fixed or withdrawable circuit breaker?

This product is a withdrawable moving part (WMP) designed for use with the corresponding ABB SACE Emax 2 fixed part to form a complete withdrawable air circuit breaker installation.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high-current switching, comprehensive electronic protection, generator-focused functionality and advanced power management with flexible withdrawable switchgear integration for demanding low-voltage electrical systems.