1SDA072350R1 ABB E2.2N 1600 Ekip G Hi-Touch LSIG 3p WMP Air Circuit Breaker 1600 A

1SDA072350R1 ABB E2.2N 1600 Ekip G Hi-Touch LSIG 3p WMP Air Circuit Breaker 1600 A

ABB 1SDA072350R1 E2.2N 1600 Ekip G Hi-Touch LSIG 3p WMP is a 1600 A three-pole withdrawable SACE Emax 2 air circuit breaker with generator-focused LSIG electronic protection, advanced power monitoring and 66 kA short-circuit breaking capacity throughout 400–690 V AC.

SKU: 1SDA072350R1MPN: 1SDA072350R1
Price
List Price £11,908.18 ex VAT
Your Price (ex VAT) Save 25%
£8,931.14 25% OFF
You save £2,977.05 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,931.14
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,931.14

Why Choose the ABB E2.2N 1600 Ekip G Hi-Touch LSIG 3p WMP Air Circuit Breaker?

The ABB E2.2N 1600 Ekip G Hi-Touch LSIG 3p WMP, order code 1SDA072350R1, is a high-performance 1600 A three-pole withdrawable air circuit breaker from the ABB SACE Emax 2 range. Designed for demanding low-voltage power distribution and generator protection applications, it combines the E2.2N frame with ABB's advanced Ekip G Hi-Touch LSIG electronic trip unit.

The Ekip G Hi-Touch LSIG release provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection. The generator-focused Ekip G Hi-Touch platform also delivers advanced measurement, monitoring and power-quality functionality, including Network Analyzer capabilities for detailed supervision of electrical network conditions.

Rated at 1600 A with an operational voltage up to 690 V AC, the E2.2N provides a rated ultimate short-circuit breaking capacity of 66 kA throughout 400–690 V AC. Its withdrawable moving-part construction, high short-time withstand capability and advanced electronic protection make the 1SDA072350R1 suitable for generator incomers, main distribution switchboards and other critical power applications.

Key Advantages

  • High-performance ABB SACE Emax 2 E2.2N air circuit breaker for generator and power distribution protection.
  • 1600 A rated uninterrupted current for high-current industrial and infrastructure systems.
  • Three-pole configuration for three-phase AC networks.
  • Ekip G Hi-Touch LSIG electronic trip unit with generator-focused protection capabilities.
  • Long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection.
  • 66 kA rated ultimate short-circuit breaking capacity throughout 400–690 V AC.
  • 66 kA Ics, equal to 100% of Icu.
  • 66 kA short-time withstand current for 1 s and 50 kA for 3 s.
  • Advanced measurement and power-quality monitoring through the Ekip G Hi-Touch platform.
  • Suitable for IT networks up to 690 V.
  • Withdrawable construction supports efficient switchboard inspection, maintenance and replacement.

Key Features

  • ABB SACE Emax 2 E2.2N series.
  • 1600 A rated current.
  • Three-pole (3P) configuration.
  • Withdrawable moving part, version W.
  • Ekip G Hi-Touch LSIG electronic release.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 66 kA Icu at 400–690 V AC.
  • 66 kA Ics with Ics equal to 100% of Icu.
  • 66 kA Icw for 1 s.
  • 50 kA Icw for 3 s.
  • 640–1600 A long-time overload adjustment range.
  • 960–16000 A short-time delayed protection adjustment range.
  • 2400–24000 A instantaneous protection adjustment range.
  • Integrated G earth-fault protection.
  • Four change-over auxiliary contacts.
  • Optional motor operator for remote or automated operation.
  • IP30 degree of protection.

Advanced Generator Protection and Network Monitoring

The ABB Ekip G Hi-Touch platform is designed for sophisticated generator and power distribution applications where comprehensive protection and detailed electrical system information are required. The LSIG functions protect against sustained overloads, delayed and severe short circuits, and earth faults, while generator-focused protection capabilities make the trip unit particularly suitable for generation and critical-power systems.

Combined with the E2.2N frame, the Ekip G Hi-Touch release provides 66 kA ultimate and service breaking capacity throughout the principal 400–690 V AC operating range. Short-time withstand ratings of 66 kA for 1 s and 50 kA for 3 s support selective protection strategies, while advanced Network Analyzer functionality provides enhanced visibility of power quality and electrical network performance.

Typical Applications

  • Generator protection and generator incomer circuits.
  • Power-generation switchboards.
  • Main low-voltage electrical distribution switchboards.
  • Industrial power distribution systems.
  • Critical and standby power systems.
  • Data centre electrical distribution.
  • Manufacturing and process plant switchgear.
  • Infrastructure and utility installations.
  • IT distribution networks up to 690 V.
  • Three-phase AC networks requiring comprehensive LSIG protection and advanced power monitoring.

Technical Specifications

Product range SACE Emax 2
Series E2.2N
Order code / MPN 1SDA072350R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker
Construction Withdrawable moving part
Version W
Number of poles 3P
Rated current (In) 1600 A
Rated uninterrupted current (Iu) 1600 A
Rated operational voltage (Ue) 690 V AC
Rated voltage (Ur) 690 V
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Current type AC
Trip unit Ekip G Hi-Touch LSIG
Release type Electronic
Protection functions L (long-time overload), S (short-time delayed short circuit), I (instantaneous short circuit) and G (earth fault)
Application focus Generator and power distribution protection
Short-circuit performance level N
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Rated service short-circuit breaking capacity (Ics) 66 kA
Ics as percentage of Icu 100%
Rated short-time withstand current (Icw) 66 kA for 1 s
Long-time overload protection adjustment 640–1600 A
Short-time delayed short-circuit protection adjustment 960–16000 A
Instantaneous short-circuit protection adjustment 2400–24000 A
Integrated earth-fault protection Yes
Connecting capacity 1200 mm²
Auxiliary contacts 4 change-over contacts
Position indication Circuit breaker open/closed
Main circuit connection Via separate fixed part / chassis
Control element Push button
Motor operator Optional
Integrated motor operator No
Integrated undervoltage release No
DIN rail mounting No
Degree of protection IP30
Suitable for IT networks Yes, up to 690 V
Power loss 288 W
Mechanical durability 25,000 operating cycles
Electrical durability at Ue ≤ 440 V 12,000 operating cycles
Electrical durability at Ue 500–690 V 10,000 operating cycles
Maximum mechanical operating frequency 60 cycles per hour
Maximum electrical operating frequency 30 cycles per hour
Dimensions (W × H × D) 317 × 425 × 383 mm
Product net weight 48 kg
Standard IEC 60947-2
EAN 8015644762001

Frequently Asked Questions

What is the ABB 1SDA072350R1 used for?

The ABB 1SDA072350R1 is a 1600 A three-pole withdrawable air circuit breaker designed for demanding generator and low-voltage power distribution applications, including generator incomers, industrial switchboards, critical power systems and main distribution boards.

What protection does the Ekip G Hi-Touch LSIG trip unit provide?

The Ekip G Hi-Touch LSIG electronic trip unit provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection, together with advanced generator protection, measurement and network-monitoring capabilities.

What is the breaking capacity of the ABB E2.2N 1600?

The E2.2N 1600 provides a rated ultimate short-circuit breaking capacity of 66 kA throughout 400–690 V AC. Its rated service short-circuit breaking capacity is also 66 kA, equal to 100% of Icu.

What are the adjustable protection ranges of the ABB 1SDA072350R1?

The long-time overload setting range is 640–1600 A, the short-time delayed short-circuit setting range is 960–16000 A, and the instantaneous short-circuit setting range is 2400–24000 A. The LSIG configuration also provides integrated earth-fault protection.

Is the ABB 1SDA072350R1 fixed or withdrawable?

The 1SDA072350R1 is a withdrawable moving part designed for installation with a compatible ABB SACE Emax 2 E2.2 fixed part, facilitating inspection, servicing and replacement within the switchboard.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, advanced electronic protection, generator-focused functionality and sophisticated power monitoring for demanding industrial, infrastructure and critical power distribution systems.