1SDA072346R1 ABB E2.2N 1600 Ekip Touch LSIG 3p WMP Air Circuit Breaker

1SDA072346R1 ABB E2.2N 1600 Ekip Touch LSIG 3p WMP Air Circuit Breaker

ABB 1SDA072346R1 SACE Emax 2 E2.2N 1600 A three-pole withdrawable air circuit breaker moving part with Ekip Touch LSIG electronic overload, short-circuit and earth-fault protection.

SKU: 1SDA072346R1MPN: 1SDA072346R1
Price
List Price £7,912.81 ex VAT
Your Price (ex VAT) Save 25%
£5,934.61 25% OFF
You save £1,978.20 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,934.61
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,934.61

Why Choose the ABB E2.2N 1600 Ekip Touch LSIG 3p WMP Air Circuit Breaker?

The ABB E2.2N 1600 Ekip Touch LSIG 3p WMP, order code 1SDA072346R1, is a SACE Emax 2 air circuit breaker moving part designed for protection and switching in demanding low-voltage AC power distribution systems. This three-pole E2.2N model combines a rated uninterrupted current of 1600 A with ABB's Ekip Touch LSIG solid-state electronic protection release.

The Ekip Touch LSIG trip unit provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection. Its touchscreen interface supports intuitive protection configuration and access to electrical and operating information, while the LSIG protection architecture provides comprehensive fault protection for complex distribution networks.

This E2.2N version is supplied as a withdrawable moving part (WMP) for use with the corresponding Emax 2 fixed part. It is rated for 1600 A, provides an ultimate short-circuit breaking capacity of 66 kA at 400 V AC, 50 Hz, and incorporates four auxiliary change-over contacts plus circuit-breaker open/closed indication for switchboard integration.

Key Advantages

  • ABB SACE Emax 2 E2.2N air circuit breaker platform for demanding low-voltage power distribution.
  • 1600 A rated uninterrupted current for high-current industrial and commercial circuits.
  • Three-pole configuration for three-phase AC power networks.
  • Ekip Touch LSIG electronic trip unit with touchscreen-based configuration.
  • Long-time, short-time delayed, instantaneous and earth-fault protection functions.
  • 66 kA ultimate short-circuit breaking capacity at 400 V AC, 50 Hz.
  • Integrated earth-fault protection provides broader protection than an LSI-only release.
  • Withdrawable construction facilitates inspection, servicing and replacement of the moving part.
  • Four auxiliary change-over contacts support breaker-status signalling and control-system integration.

Key Features

  • ABB SACE Emax 2 E2.2N series.
  • 1600 A rated uninterrupted current.
  • 3-pole circuit-breaker configuration.
  • Ekip Touch LSIG solid-state electronic release.
  • Long-time overload protection (L).
  • Short-time delayed short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Integrated earth-fault protection (G).
  • 66 kA Icu at 400 V AC, 50 Hz.
  • Withdrawable moving part (WMP) construction.
  • Four auxiliary change-over contacts.
  • Circuit-breaker open/closed position indication.
  • Push-button operating control.
  • Optional motor drive capability.
  • IP30 degree of protection.

Comprehensive LSIG Protection for High-Current Power Distribution

The ABB SACE Emax 2 E2.2N is designed to protect high-current low-voltage distribution circuits against overload, short-circuit and earth-fault conditions. Its Ekip Touch LSIG release combines long-time overload protection with short-time delayed, instantaneous and earth-fault functions, enabling comprehensive protection and supporting coordinated fault isolation throughout the electrical network.

The withdrawable design allows the breaker moving part to be separated from its compatible fixed chassis for inspection, servicing or replacement. Combined with electronic protection, four auxiliary change-over contacts, breaker-position indication and optional motor operation, the E2.2N is well suited to modern switchboards where maintainability, operational continuity and dependable high-current protection are important.

Typical Applications

  • Industrial low-voltage power distribution switchboards.
  • Main incomer and high-current feeder protection.
  • Manufacturing and process-industry electrical systems.
  • Commercial building power distribution.
  • Transformer secondary distribution systems.
  • Data centres and critical power infrastructure.
  • Utility and infrastructure electrical installations.
  • Three-phase AC networks requiring comprehensive LSIG protection.
  • High-fault-current distribution systems requiring 66 kA breaking capacity.
  • Withdrawable switchgear requiring maintainable high-current circuit protection.

Technical Specifications

Series SACE Emax 2 E2.2
ABB order code 1SDA072346R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker moving part
Performance level N
Version Withdrawable moving part (WMP)
Number of poles 3
Rated uninterrupted current Iu 1600 A
Rated operational voltage 690 V AC
Rated ultimate short-circuit breaking capacity Icu at 400 V AC, 50 Hz 66 kA
Protection release Ekip Touch LSIG
Release technology Solid-state electronic
Protection functions Long-time overload (L), short-time delayed short circuit (S), instantaneous short circuit (I) and earth fault (G)
Integrated earth-fault protection Yes
Auxiliary contacts 4 change-over contacts
Breaker indication Open / closed
Main-circuit connection Connection at separate chassis part
Device construction Withdrawable slide-in technique
Operating control Push button
Integrated undervoltage release No
Motor drive Optional
Degree of protection IP30
Power loss 288 W
EAN 8015644761967

Frequently Asked Questions

What is the ABB 1SDA072346R1?

The ABB 1SDA072346R1 is a SACE Emax 2 E2.2N 1600 A three-pole withdrawable air circuit breaker moving part equipped with an Ekip Touch LSIG solid-state electronic protection release, four auxiliary change-over contacts and breaker open/closed indication.

What protection functions does the Ekip Touch LSIG release provide?

The Ekip Touch LSIG release provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and integrated earth-fault protection.

What is the rated current of the ABB E2.2N 1SDA072346R1?

The ABB E2.2N 1SDA072346R1 has a rated uninterrupted current of 1600 A, making it suitable for substantial industrial, commercial and infrastructure power-distribution circuits.

What is the short-circuit breaking capacity of the E2.2N 1600?

The E2.2N 1600 has a rated ultimate short-circuit breaking capacity of 66 kA at 400 V AC, 50 Hz, providing robust fault interruption for demanding low-voltage distribution systems.

Is the ABB 1SDA072346R1 a fixed or withdrawable circuit breaker?

This product is a withdrawable moving part (WMP) designed for connection to the corresponding ABB SACE Emax 2 fixed chassis part to form a complete withdrawable air circuit breaker installation.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high-current switching, comprehensive electronic protection and flexible withdrawable switchgear integration to provide dependable protection for demanding industrial, commercial and infrastructure power-distribution systems.