ABB 1SDA072345R1 SACE Emax 2 E2.2N 1600 A three-pole withdrawable air circuit breaker moving part with Ekip Touch LSI electronic overload and selective short-circuit protection.

SKU: 1SDA072345R1MPN: 1SDA072345R1
Price
List Price £7,211.20 ex VAT
Your Price (ex VAT) Save 25%
£5,408.40 25% OFF
You save £1,802.80 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,408.40
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,408.40

Why Choose the ABB E2.2N 1600 Ekip Touch LSI 3p WMP Air Circuit Breaker?

The ABB E2.2N 1600 Ekip Touch LSI 3p WMP, order code 1SDA072345R1, is a SACE Emax 2 air circuit breaker moving part designed for protection and switching in demanding low-voltage AC power distribution systems. This three-pole E2.2N model combines a rated current of 1600 A with ABB's Ekip Touch LSI solid-state electronic protection release.

The Ekip Touch LSI trip unit provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. Its touch-sensitive display provides intuitive configuration of the protection functions, while adjustable LSI settings support selective coordination between protective devices throughout complex electrical distribution networks.

This E2.2N version is supplied as a withdrawable moving part (WMP) and is fitted with four auxiliary contacts plus circuit-breaker open/closed position indication. Rated for operation up to 690 V AC and providing an ultimate short-circuit breaking capacity of 66 kA across its principal low-voltage AC ratings, it is engineered for reliable high-current power distribution.

Key Advantages

  • ABB SACE Emax 2 E2.2N air circuit breaker platform for demanding low-voltage distribution systems.
  • 1600 A rated current for high-current industrial and commercial circuits.
  • Three-pole configuration for three-phase AC power networks.
  • Ekip Touch LSI electronic trip unit with touch-sensitive display.
  • Long-time, short-time delayed and instantaneous protection functions.
  • 66 kA ultimate short-circuit breaking capacity at 400/415 V AC.
  • Ics equal to 100% of Icu for strong service short-circuit performance.
  • Adjustable protection settings support selective coordination within distribution systems.
  • Withdrawable construction facilitates inspection, servicing and replacement of the moving part.
  • Four auxiliary contacts and breaker-position indication support switchboard signalling and control.

Key Features

  • ABB SACE Emax 2 E2.2N series.
  • 1600 A rated current.
  • 3-pole circuit-breaker configuration.
  • Ekip Touch LSI solid-state electronic release.
  • Long-time overload protection (L).
  • Short-time delayed short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Overload protection adjustable from 0.4–1 × In.
  • Short-time protection adjustable from 0.6–10 × In.
  • Instantaneous protection adjustable from 1.5–15 × In.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 66 kA Icu at 400/415 V AC.
  • Withdrawable moving part (WMP) construction.
  • Four auxiliary contacts.
  • Circuit-breaker open/closed position indication.

Selective Protection for High-Current Power Distribution

The ABB SACE Emax 2 E2.2N is designed to protect high-current low-voltage distribution circuits against overload and short-circuit conditions. Its Ekip Touch LSI release combines long-time overload protection with short-time delayed and instantaneous short-circuit protection, enabling engineers to coordinate protection settings and improve selectivity between devices across the electrical network.

The withdrawable design allows the breaker moving part to be separated from its compatible fixed part for inspection, servicing or replacement. Combined with electronic protection, auxiliary contacts and breaker-position indication, this construction makes the E2.2N particularly suitable for switchboards where maintainability, operational continuity and dependable high-current protection are important.

Typical Applications

  • Industrial low-voltage power distribution switchboards.
  • Main incomer and high-current feeder protection.
  • Manufacturing and process-industry electrical systems.
  • Commercial building power distribution.
  • Transformer secondary distribution systems.
  • Data centres and critical power infrastructure.
  • Utility and infrastructure electrical installations.
  • Three-phase AC networks requiring selective LSI protection.
  • High-fault-current distribution systems requiring 66 kA breaking capacity.
  • Withdrawable switchgear requiring maintainable high-current circuit protection.

Technical Specifications

Series SACE Emax 2 E2.2
ABB order code 1SDA072345R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker moving part
Performance level N
Version Withdrawable moving part (WMP)
Number of poles 3
Rated current In 1600 A
Current type AC
Rated operational voltage Ue 690 V AC
Rated insulation voltage Ui 1000 V AC
Rated impulse withstand voltage Uimp 12 kV
Frequency 50/60 Hz
Icu at 380 V AC 66 kA
Icu at 400/415 V AC 66 kA
Icu at 440 V AC 66 kA
Icu at 500/525 V AC 66 kA
Icu at 690 V AC 66 kA
Rated service short-circuit breaking capacity Ics 100% of Icu
Protection release Ekip Touch LSI
Release type Solid-state electronic
Protection functions Long-time overload (L), short-time delayed short circuit (S) and instantaneous short circuit (I)
Overload protection setting 0.4–1 × In
Short-time protection setting 0.6–10 × In
Instantaneous protection setting 1.5–15 × In
Integrated earth-fault protection No
User interface Touch-sensitive display
Auxiliary contacts 4
Breaker indication Open / closed
Electrical durability at Ue ≤ 440 V 12,000 operating cycles
Electrical durability at Ue 500–690 V 10,000 operating cycles
Maximum electrical operating frequency 30 cycles per hour
Mechanical durability 25,000 operating cycles
Maximum mechanical operating frequency 60 cycles per hour
Power loss 288 W
Dimensions (W × H × D) 317 × 425 × 383 mm
Net weight 49 kg
Standard IEC 60947-2
EAN 8015644761950

Frequently Asked Questions

What is the ABB 1SDA072345R1?

The ABB 1SDA072345R1 is a SACE Emax 2 E2.2N 1600 A three-pole withdrawable air circuit breaker moving part equipped with an Ekip Touch LSI solid-state electronic protection release.

What protection functions does the Ekip Touch LSI release provide?

The Ekip Touch LSI release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. This LSI configuration does not include the integrated earth-fault protection provided by LSIG versions.

What is the rated current of the ABB E2.2N 1SDA072345R1?

The ABB E2.2N 1SDA072345R1 has a rated current of 1600 A. Its long-time overload protection is adjustable from 0.4–1 × In.

What is the short-circuit breaking capacity of the E2.2N 1600?

The E2.2N 1600 provides an ultimate short-circuit breaking capacity of 66 kA at 380 V, 400/415 V, 440 V, 500/525 V and 690 V AC.

Is the ABB 1SDA072345R1 a fixed or withdrawable circuit breaker?

This product is a withdrawable moving part (WMP) designed for use with the corresponding ABB SACE Emax 2 fixed part to form a complete withdrawable air circuit breaker installation.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high-current switching, configurable electronic protection and flexible withdrawable switchgear integration to provide dependable protection for demanding industrial, commercial and infrastructure power-distribution systems.