1SDA072330R1 ABB E2.2H 1250 Ekip G Hi-Touch LSIG 3p WMP Air Circuit Breaker

1SDA072330R1 ABB E2.2H 1250 Ekip G Hi-Touch LSIG 3p WMP Air Circuit Breaker

ABB 1SDA072330R1 SACE Emax 2 E2.2H 1250 A three-pole withdrawable air circuit breaker moving part with Ekip G Hi-Touch LSIG electronic protection for generator and advanced power-distribution applications.

SKU: 1SDA072330R1MPN: 1SDA072330R1
Price
List Price £12,278.51 ex VAT
Your Price (ex VAT) Save 25%
£9,208.88 25% OFF
You save £3,069.63 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,208.88
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,208.88

Why Choose the ABB E2.2H 1250 Ekip G Hi-Touch LSIG 3p WMP Air Circuit Breaker?

The ABB E2.2H 1250 Ekip G Hi-Touch LSIG 3p WMP, order code 1SDA072330R1, is a high-performance SACE Emax 2 air circuit breaker moving part designed for advanced protection, switching and power management in demanding low-voltage AC systems. This three-pole E2.2H model combines a rated uninterrupted current of 1250 A with ABB's Ekip G Hi-Touch LSIG solid-state electronic protection release.

The Ekip G Hi-Touch LSIG release combines generator-oriented functionality with long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection. The Hi-Touch platform extends the breaker beyond conventional circuit protection with advanced measurement, monitoring and power-management capabilities, making it particularly well suited to generator, critical-power and sophisticated distribution applications.

This E2.2H version is supplied as a withdrawable moving part (WMP) for use with the corresponding Emax 2 fixed part. With an ultimate short-circuit breaking capacity of 100 kA at 400–440 V AC, 85 kA at 500–690 V AC and a short-time withstand current of 85 kA for 1 s, it provides robust protection for networks with substantial prospective fault currents.

Key Advantages

  • High-performance ABB SACE Emax 2 E2.2H air circuit breaker platform.
  • 1250 A rated uninterrupted current for high-current power systems.
  • Three-pole configuration for three-phase AC networks.
  • Ekip G Hi-Touch LSIG electronic release with generator-oriented protection and advanced power-management functionality.
  • Long-time, short-time, instantaneous and earth-fault protection for comprehensive circuit protection.
  • 100 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 85 kA short-time withstand current for 1 s supports selective protection strategies.
  • Advanced Hi-Touch measurement and monitoring capabilities support detailed supervision of electrical systems.
  • Withdrawable construction facilitates inspection, servicing and replacement of the breaker moving part.
  • Four auxiliary change-over contacts support breaker-status signalling and switchboard automation.

Key Features

  • ABB SACE Emax 2 E2.2H series.
  • 1250 A rated current.
  • 3-pole circuit-breaker configuration.
  • Ekip G Hi-Touch LSIG solid-state electronic release.
  • Generator-oriented Ekip G protection and power-management platform.
  • Long-time overload protection (L).
  • Short-time delayed short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Integrated earth-fault protection (G).
  • 690 V AC rated operational voltage.
  • 100 kA Icu at 400–440 V AC.
  • 85 kA Icu at 500–690 V AC.
  • 85 kA Icw for 1 s.
  • 66 kA Icw for 3 s.
  • Withdrawable moving part (WMP) construction.
  • Four auxiliary change-over contacts.
  • Circuit-breaker open/closed position indication.
  • Optional motor drive capability.
  • Suitable for IT networks up to 690 V.

Advanced Generator and High-Current Power Protection

The ABB SACE Emax 2 E2.2H provides comprehensive protection for high-current low-voltage electrical systems. Its Ekip G Hi-Touch LSIG release combines long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection with functionality designed for generator and advanced power-management applications, helping engineers coordinate protection across generation and downstream distribution equipment.

The E2.2H frame combines high short-circuit breaking and withstand performance with the maintainability of a withdrawable design. The moving part can be separated from the compatible fixed part for inspection, servicing or replacement, while the advanced Ekip G Hi-Touch platform supports sophisticated supervision of critical industrial, infrastructure and power-generation systems.

Typical Applications

  • Generator protection and generator switchboards.
  • Industrial low-voltage power distribution systems.
  • Main incomer and high-current feeder protection.
  • Standby and emergency power-generation systems.
  • Manufacturing and process-industry electrical networks.
  • Data centres and critical power infrastructure.
  • Commercial and infrastructure distribution switchboards.
  • High-fault-level three-phase AC distribution networks.
  • Power systems requiring comprehensive LSIG protection and advanced monitoring.
  • Withdrawable switchgear requiring generator-oriented electronic protection.

Technical Specifications

Series SACE Emax 2 E2.2
ABB order code 1SDA072330R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker moving part
Performance level H
Version Withdrawable moving part (WMP)
Number of poles 3
Rated current In 1250 A
Rated uninterrupted current Iu 1250 A
Current type AC
Rated operational voltage 690 V AC
Rated insulation voltage Ui 1000 V AC
Rated impulse withstand voltage Uimp 12 kV
Icu at 400 V AC 100 kA
Icu at 415 V AC 100 kA
Icu at 440 V AC 100 kA
Icu at 500 V AC 85 kA
Icu at 525 V AC 85 kA
Icu at 690 V AC 85 kA
Rated service short-circuit breaking capacity Ics 100% of Icu
Rated short-time withstand current Icw (1 s) 85 kA
Rated short-time withstand current Icw (3 s) 66 kA
Protection release Ekip G Hi-Touch LSIG
Release type Electronic
Protection functions Long-time overload (L), short-time delayed short circuit (S), instantaneous short circuit (I) and earth fault (G)
Integrated earth-fault protection Yes
Generator-oriented protection Ekip G platform
Auxiliary contacts 4 change-over contacts
Breaker indication Open / closed
Main-circuit connection Connection at separate fixed chassis part
Operating control Push button
Integrated undervoltage release No
Motor drive Optional
Degree of protection IP30
Electrical durability 15,000 operating cycles
Mechanical durability 25,000 operating cycles
Power loss 176 W
Dimensions (W × H × D) 317 × 425 × 383 mm
Net weight 48 kg
Suitable for IT networks Yes, up to 690 V
Standard IEC
EAN 8015644761806

Frequently Asked Questions

What is the ABB 1SDA072330R1?

The ABB 1SDA072330R1 is a SACE Emax 2 E2.2H 1250 A three-pole withdrawable air circuit breaker moving part equipped with an Ekip G Hi-Touch LSIG solid-state electronic protection release.

What protection functions does the Ekip G Hi-Touch LSIG release provide?

The Ekip G Hi-Touch LSIG release provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and integrated earth-fault protection, together with advanced generator-oriented protection, measurement and power-management functionality.

What is the rated current of the ABB E2.2H 1SDA072330R1?

The ABB E2.2H 1SDA072330R1 has a rated uninterrupted current of 1250 A, making it suitable for substantial industrial, infrastructure, generator and critical-power distribution systems.

What is the short-circuit performance of the E2.2H 1250?

The E2.2H 1250 provides an ultimate short-circuit breaking capacity of 100 kA at 400–440 V AC and 85 kA at 500–690 V AC, together with short-time withstand ratings of 85 kA for 1 s and 66 kA for 3 s.

Is the ABB 1SDA072330R1 a fixed or withdrawable circuit breaker?

This product is a withdrawable moving part (WMP) designed for use with the corresponding ABB SACE Emax 2 fixed part to form a complete withdrawable air circuit breaker installation.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high-current switching, comprehensive electronic protection, generator-focused functionality and advanced power management with flexible withdrawable switchgear integration for demanding low-voltage electrical systems.