1SDA072326R1 ABB E2.2H 1250 Ekip Touch LSIG 3p WMP Air Circuit Breaker

1SDA072326R1 ABB E2.2H 1250 Ekip Touch LSIG 3p WMP Air Circuit Breaker

ABB 1SDA072326R1 Emax 2 E2.2H 1250 is a 1250 A three-pole withdrawable air circuit breaker with Ekip Touch LSIG electronic protection and a 100 kA breaking capacity at 400/415 V AC for demanding low-voltage power distribution systems.

SKU: 1SDA072326R1MPN: 1SDA072326R1
Price
List Price £8,302.60 ex VAT
Your Price (ex VAT) Save 25%
£6,226.95 25% OFF
You save £2,075.65 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,226.95
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,226.95

Why Choose the ABB E2.2H 1250 Ekip Touch LSIG 3p WMP Air Circuit Breaker?

The ABB E2.2H 1250 Ekip Touch LSIG 3p WMP, order code 1SDA072326R1, is a high-performance air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for comprehensive protection and control of demanding low-voltage electrical distribution systems. Combining the E2.2H frame with a 1250 A rated uninterrupted current and Ekip Touch LSIG electronic trip unit, it provides advanced overload, short-circuit and earth-fault protection for industrial, commercial and infrastructure power networks.

The Ekip Touch LSIG solid-state electronic release provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection. Adjustable protection thresholds allow the breaker to be coordinated with other protective devices throughout the network, while the Ekip Touch interface provides convenient access to protection settings and operating information.

The E2.2H performance level delivers a rated ultimate short-circuit breaking capacity of 100 kA at 400/415 V AC and 85 kA at 500–690 V AC, with a rated short-time withstand current of 85 kA for 1 s. This three-pole WMP version is supplied as a withdrawable moving part and includes four auxiliary changeover contacts plus circuit-breaker open/closed position indication.

Key Advantages

  • High-performance 1250 A Emax 2 air circuit breaker for demanding low-voltage power distribution.
  • 100 kA ultimate breaking capacity at 400/415 V AC for installations with high prospective fault currents.
  • Ekip Touch LSIG electronic trip unit provides long-time, short-time, instantaneous and earth-fault protection.
  • Adjustable electronic protection settings support selective coordination throughout the electrical network.
  • 85 kA short-time withstand current for 1 s supports demanding selectivity requirements.
  • Withdrawable moving-part construction supports efficient inspection, maintenance and breaker replacement.

Key Features

  • ABB SACE Emax 2 E2.2H series.
  • 1250 A rated uninterrupted current.
  • Three-pole configuration.
  • 690 V AC rated operational voltage.
  • 100 kA Icu at 400–440 V AC.
  • 85 kA Icu at 500–690 V AC.
  • 85 kA Icw for 1 s.
  • Ekip Touch LSIG electronic trip unit.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • Four auxiliary changeover contacts.
  • Circuit-breaker open/closed position indication.
  • Suitable for IT networks up to 690 V.
  • Withdrawable moving-part configuration for compatible Emax 2 switchgear.

Comprehensive LSIG Protection for High-Fault-Level Networks

ABB SACE Emax 2 air circuit breakers are engineered to protect low-voltage electrical networks where high current capacity, selective coordination and dependable fault interruption are essential. The E2.2H performance level offers particularly high short-circuit breaking capability, making it suitable for main distribution boards, industrial switchgear and installations with substantial prospective fault currents.

The Ekip Touch LSIG trip unit combines long-time overload protection with short-time delayed, instantaneous and earth-fault protection. Together with the breaker’s high short-time withstand capability, these functions allow engineers to develop coordinated protection strategies that isolate faults close to their source while helping maintain continuity of supply to unaffected sections of the electrical system.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Main incoming electrical supplies.
  • Manufacturing and process plants.
  • Commercial and infrastructure electrical distribution.
  • Installations with high prospective short-circuit currents.
  • Electrical systems requiring comprehensive LSIG protection and selective coordination.

Technical Specifications

Product range SACE Emax 2
Frame E2.2H
Order code / MPN 1SDA072326R1
Product type Air circuit breaker
Rated uninterrupted current (Iu) 1250 A
Number of poles 3
Rated operational voltage 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 85 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw) 85 kA for 1 s; 66 kA for 3 s
Performance level H
Trip unit Ekip Touch LSIG
Release type Electronic / solid-state
Protection functions Long-time, short-time, instantaneous and earth fault (LSIG)
Overload release adjustment 500–1250 A
Short-time delayed short-circuit adjustment 750–12500 A
Instantaneous short-circuit adjustment 1875–18750 A
Integrated earth-fault protection Yes
Auxiliary contacts 4 changeover contacts
Position indication Circuit breaker open / closed
Motor drive Optional
Suitable for IT networks Yes, up to 690 V
Installation Withdrawable
Configuration Moving part (WMP)
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA072326R1 used for?

The ABB 1SDA072326R1 is a 1250 A three-pole air circuit breaker designed to protect and control demanding low-voltage electrical distribution systems, particularly where high short-circuit breaking performance and comprehensive LSIG protection are required.

What is the current rating of the ABB E2.2H 1250?

The ABB E2.2H 1250 has a rated uninterrupted current of 1250 A.

What is the breaking capacity of the ABB 1SDA072326R1?

The E2.2H has a rated ultimate short-circuit breaking capacity of 100 kA at 400–440 V AC and 85 kA at 500–690 V AC.

What protection does the Ekip Touch LSIG trip unit provide?

The Ekip Touch LSIG electronic trip unit provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection, supporting comprehensive protection and selective coordination within low-voltage distribution systems.

Is the ABB 1SDA072326R1 fixed or withdrawable?

The 1SDA072326R1 is supplied as a withdrawable moving part (WMP) for installation within a compatible ABB Emax 2 withdrawable circuit-breaker assembly.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine dependable electrical protection, advanced electronic trip technology and high short-circuit performance for demanding industrial, commercial and infrastructure power-distribution systems.