ABB 1SDA072326R1 Emax 2 E2.2H 1250 is a 1250 A three-pole withdrawable air circuit breaker with Ekip Touch LSIG electronic protection and a 100 kA breaking capacity at 400/415 V AC for demanding low-voltage power distribution systems.
£6,226.95
The ABB E2.2H 1250 Ekip Touch LSIG 3p WMP, order code 1SDA072326R1, is a high-performance air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for comprehensive protection and control of demanding low-voltage electrical distribution systems. Combining the E2.2H frame with a 1250 A rated uninterrupted current and Ekip Touch LSIG electronic trip unit, it provides advanced overload, short-circuit and earth-fault protection for industrial, commercial and infrastructure power networks.
The Ekip Touch LSIG solid-state electronic release provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection. Adjustable protection thresholds allow the breaker to be coordinated with other protective devices throughout the network, while the Ekip Touch interface provides convenient access to protection settings and operating information.
The E2.2H performance level delivers a rated ultimate short-circuit breaking capacity of 100 kA at 400/415 V AC and 85 kA at 500–690 V AC, with a rated short-time withstand current of 85 kA for 1 s. This three-pole WMP version is supplied as a withdrawable moving part and includes four auxiliary changeover contacts plus circuit-breaker open/closed position indication.
ABB SACE Emax 2 air circuit breakers are engineered to protect low-voltage electrical networks where high current capacity, selective coordination and dependable fault interruption are essential. The E2.2H performance level offers particularly high short-circuit breaking capability, making it suitable for main distribution boards, industrial switchgear and installations with substantial prospective fault currents.
The Ekip Touch LSIG trip unit combines long-time overload protection with short-time delayed, instantaneous and earth-fault protection. Together with the breaker’s high short-time withstand capability, these functions allow engineers to develop coordinated protection strategies that isolate faults close to their source while helping maintain continuity of supply to unaffected sections of the electrical system.
| Product range | SACE Emax 2 |
|---|---|
| Frame | E2.2H |
| Order code / MPN | 1SDA072326R1 |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 1250 A |
| Number of poles | 3 |
| Rated operational voltage | 690 V AC |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC | 85 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 85 kA |
| Rated service short-circuit breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw) | 85 kA for 1 s; 66 kA for 3 s |
| Performance level | H |
| Trip unit | Ekip Touch LSIG |
| Release type | Electronic / solid-state |
| Protection functions | Long-time, short-time, instantaneous and earth fault (LSIG) |
| Overload release adjustment | 500–1250 A |
| Short-time delayed short-circuit adjustment | 750–12500 A |
| Instantaneous short-circuit adjustment | 1875–18750 A |
| Integrated earth-fault protection | Yes |
| Auxiliary contacts | 4 changeover contacts |
| Position indication | Circuit breaker open / closed |
| Motor drive | Optional |
| Suitable for IT networks | Yes, up to 690 V |
| Installation | Withdrawable |
| Configuration | Moving part (WMP) |
| Standard | IEC |
The ABB 1SDA072326R1 is a 1250 A three-pole air circuit breaker designed to protect and control demanding low-voltage electrical distribution systems, particularly where high short-circuit breaking performance and comprehensive LSIG protection are required.
The ABB E2.2H 1250 has a rated uninterrupted current of 1250 A.
The E2.2H has a rated ultimate short-circuit breaking capacity of 100 kA at 400–440 V AC and 85 kA at 500–690 V AC.
The Ekip Touch LSIG electronic trip unit provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection, supporting comprehensive protection and selective coordination within low-voltage distribution systems.
The 1SDA072326R1 is supplied as a withdrawable moving part (WMP) for installation within a compatible ABB Emax 2 withdrawable circuit-breaker assembly.
ABB SACE Emax 2 air circuit breakers combine dependable electrical protection, advanced electronic trip technology and high short-circuit performance for demanding industrial, commercial and infrastructure power-distribution systems.