1SDA072325R1 ABB E2.2H 1250 Ekip Touch LSI 3p WMP Air Circuit Breaker

1SDA072325R1 ABB E2.2H 1250 Ekip Touch LSI 3p WMP Air Circuit Breaker

ABB 1SDA072325R1 Emax 2 E2.2H 1250 is a 1250 A three-pole withdrawable air circuit breaker with Ekip Touch LSI electronic protection and a 100 kA breaking capacity at 400/415 V AC for demanding low-voltage power distribution systems.

SKU: 1SDA072325R1MPN: 1SDA072325R1
Price
List Price £7,581.46 ex VAT
Your Price (ex VAT) Save 25%
£5,686.10 25% OFF
You save £1,895.37 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,686.10
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,686.10

Why Choose the ABB E2.2H 1250 Ekip Touch LSI 3p WMP Air Circuit Breaker?

The ABB E2.2H 1250 Ekip Touch LSI 3p WMP, order code 1SDA072325R1, is a high-performance air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for advanced protection and control of demanding low-voltage electrical distribution systems. Combining the E2.2H frame with a 1250 A rated uninterrupted current and Ekip Touch LSI electronic trip unit, it provides reliable overload and short-circuit protection for industrial, commercial and infrastructure power networks.

The Ekip Touch LSI electronic trip unit provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. Adjustable electronic protection settings and the touch-sensitive display support straightforward configuration, while the short-time protection function enables selective coordination between protective devices throughout the electrical network.

The E2.2H performance level delivers a rated ultimate short-circuit breaking capacity of 100 kA at 380–440 V AC and 85 kA at 500–690 V AC. This three-pole WMP configuration is supplied as a withdrawable moving part, providing convenient inspection, maintenance and replacement within compatible ABB Emax 2 withdrawable switchgear assemblies.

Key Advantages

  • High-performance 1250 A Emax 2 air circuit breaker for demanding low-voltage power distribution.
  • 100 kA ultimate breaking capacity at 400/415 V AC for installations with high prospective fault currents.
  • Ekip Touch LSI electronic trip unit provides long-time, short-time and instantaneous protection.
  • Adjustable protection thresholds support effective selectivity and system coordination.
  • Touch-sensitive Ekip interface simplifies protection configuration and access to operating information.
  • Withdrawable moving-part construction supports efficient inspection, maintenance and breaker replacement.

Key Features

  • ABB SACE Emax 2 E2.2H series.
  • 1250 A rated uninterrupted current.
  • Three-pole configuration.
  • 690 V AC rated operational voltage.
  • 100 kA Icu at 380–440 V AC.
  • 85 kA Icu at 500–690 V AC.
  • Ekip Touch LSI electronic trip unit.
  • Long-time overload protection adjustable from 0.4–1 × In.
  • Short-time selective short-circuit protection adjustable from 0.6–10 × In.
  • Instantaneous short-circuit protection adjustable from 1.5–15 × In.
  • Touch-sensitive display for protection configuration.
  • Withdrawable moving-part configuration for compatible Emax 2 switchgear.

High-Performance LSI Protection for Power Distribution

ABB SACE Emax 2 air circuit breakers are engineered for the protection and control of low-voltage electrical networks where high current capacity and dependable fault interruption are required. The E2.2H performance level provides particularly high short-circuit breaking capability, making this breaker well suited to main distribution boards, industrial switchgear and installations with substantial prospective fault currents.

The Ekip Touch LSI trip unit combines long-time overload protection with adjustable short-time and instantaneous short-circuit protection. The short-time function supports selective coordination between upstream and downstream protective devices, helping isolate faults close to their source while maintaining continuity of supply to unaffected sections of the electrical network.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Main incoming electrical supplies.
  • Manufacturing and process plants.
  • Commercial and infrastructure electrical distribution.
  • Installations with high prospective short-circuit currents.
  • Electrical systems requiring selective LSI protection and coordination.

Technical Specifications

Product range SACE Emax 2
Frame E2.2H
Order code / MPN 1SDA072325R1
EAN 8015644761752
Product type Air circuit breaker
Rated uninterrupted current (Iu) 1250 A
Number of poles 3
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50 / 60 Hz
Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 85 kA
Performance level H
Trip unit Ekip Touch LSI
Release type Electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Overload protection adjustment 0.4–1 × In
Short-time selective protection adjustment 0.6–10 × In
Instantaneous protection adjustment 1.5–15 × In
Earth-fault protection Not included in the LSI configuration
Installation Withdrawable
Configuration Moving part (WMP)
Approximate weight 53 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA072325R1 used for?

The ABB 1SDA072325R1 is a 1250 A three-pole air circuit breaker designed to protect and control demanding low-voltage electrical distribution systems, particularly where high short-circuit breaking performance is required.

What is the current rating of the ABB E2.2H 1250?

The ABB E2.2H 1250 has a rated uninterrupted current of 1250 A.

What is the breaking capacity of the ABB 1SDA072325R1?

The E2.2H has a rated ultimate short-circuit breaking capacity of 100 kA at 380–440 V AC and 85 kA at 500–690 V AC.

What protection does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI electronic trip unit provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection, supporting selective coordination within low-voltage distribution systems.

Is the ABB 1SDA072325R1 fixed or withdrawable?

The 1SDA072325R1 is supplied as a withdrawable moving part (WMP) for installation within a compatible ABB Emax 2 withdrawable circuit-breaker assembly.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine dependable electrical protection, advanced electronic trip technology and high short-circuit performance for demanding industrial, commercial and infrastructure power-distribution systems.