ABB 1SDA072318R1 SACE Emax 2 E2.2S 1250 A three-pole withdrawable air circuit breaker moving part with Ekip Hi-Touch LSI electronic overload and selective short-circuit protection.
£7,907.93
The ABB E2.2S 1250 Ekip Hi-Touch LSI 3p WMP, order code 1SDA072318R1, is a high-performance SACE Emax 2 air circuit breaker moving part designed for advanced protection and switching in demanding low-voltage AC power distribution systems. This three-pole E2.2S model combines a rated uninterrupted current of 1250 A with ABB's advanced Ekip Hi-Touch LSI electronic protection release.
The Ekip Hi-Touch LSI trip unit provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. The Hi-Touch platform provides advanced protection, measurement and monitoring functionality for applications requiring sophisticated power-system supervision and selective coordination, while the LSI configuration focuses protection on overload and short-circuit conditions.
This version is supplied as a withdrawable moving part (WMP) for use with the corresponding Emax 2 fixed part. With an ultimate short-circuit breaking capacity of 85 kA at 415 V AC and 66 kA at 690 V AC, the E2.2S is engineered for substantial industrial, commercial, infrastructure and critical power-distribution duties.
The ABB SACE Emax 2 E2.2S provides dependable protection for high-current low-voltage distribution circuits. Its Ekip Hi-Touch LSI release combines long-time overload protection with short-time delayed and instantaneous short-circuit functions, enabling coordinated fault protection while providing the advanced measurement and monitoring capabilities associated with ABB's Hi-Touch platform.
The E2.2S frame combines strong short-circuit performance with the serviceability of a withdrawable design. The moving part can be separated from the compatible fixed part for inspection, servicing or replacement, while auxiliary contacts and breaker-position indication support integration into switchboard monitoring and automation systems.
| Series | SACE Emax 2 E2.2 |
|---|---|
| ABB order code | 1SDA072318R1 |
| Product group | Emax2 Air Circuit Breaker |
| Product type | Air circuit breaker moving part |
| Performance level | S |
| Version | Withdrawable moving part (WMP) |
| Number of poles | 3 |
| Rated uninterrupted current Iu | 1250 A |
| Rated voltage | 690 V AC |
| Rated ultimate short-circuit breaking capacity Icu at 400–415 V AC | 85 kA |
| Rated ultimate short-circuit breaking capacity Icu at 690 V AC | 66 kA |
| Rated short-time withstand current Icw (1 s) | 66 kA |
| Protection release | Ekip Hi-Touch LSI |
| Release technology | Solid-state electronic |
| Protection functions | Long-time overload (L), short-time delayed short circuit (S) and instantaneous short circuit (I) |
| Overload release setting range | 500–1250 A |
| Short-time delayed short-circuit setting range | 750–12500 A |
| Instantaneous short-circuit setting range | 1875–18750 A |
| Integrated earth-fault protection | No |
| Auxiliary contacts | 4 change-over contacts |
| Breaker position indication | Open / closed |
| Trip indication contact | S51 |
| Main-circuit connection | Via separate fixed part |
| Motor drive | Optional |
| Dimensions | 317 × 425 × 383 mm |
| Net weight | 48 kg |
| Standard | IEC |
The ABB 1SDA072318R1 is a SACE Emax 2 E2.2S 1250 A three-pole withdrawable air circuit breaker moving part equipped with an Ekip Hi-Touch LSI solid-state electronic protection release.
The Ekip Hi-Touch LSI release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. This LSI configuration does not include the integrated earth-fault protection provided by LSIG versions.
The circuit breaker has a rated uninterrupted current of 1250 A, with an overload release setting range of 500–1250 A.
The E2.2S 1250 provides an ultimate short-circuit breaking capacity of 85 kA at 400–415 V AC and 66 kA at 690 V AC, together with a rated short-time withstand current of 66 kA for 1 s.
This product is a withdrawable moving part (WMP) designed for use with the corresponding ABB SACE Emax 2 fixed part, which is ordered separately, to form a complete withdrawable air circuit breaker installation.
ABB SACE Emax 2 air circuit breakers combine high-current switching, advanced electronic protection, sophisticated power-system monitoring and flexible withdrawable switchgear integration for dependable protection in demanding low-voltage distribution systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.