1SDA072318R1 ABB E2.2S 1250 Ekip Hi-Touch LSI 3p WMP Air Circuit Breaker

1SDA072318R1 ABB E2.2S 1250 Ekip Hi-Touch LSI 3p WMP Air Circuit Breaker

ABB 1SDA072318R1 SACE Emax 2 E2.2S 1250 A three-pole withdrawable air circuit breaker moving part with Ekip Hi-Touch LSI electronic overload and selective short-circuit protection.

SKU: 1SDA072318R1MPN: 1SDA072318R1
Price
List Price £10,543.91 ex VAT
Your Price (ex VAT) Save 25%
£7,907.93 25% OFF
You save £2,635.98 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,907.93
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,907.93

Why Choose the ABB E2.2S 1250 Ekip Hi-Touch LSI 3p WMP Air Circuit Breaker?

The ABB E2.2S 1250 Ekip Hi-Touch LSI 3p WMP, order code 1SDA072318R1, is a high-performance SACE Emax 2 air circuit breaker moving part designed for advanced protection and switching in demanding low-voltage AC power distribution systems. This three-pole E2.2S model combines a rated uninterrupted current of 1250 A with ABB's advanced Ekip Hi-Touch LSI electronic protection release.

The Ekip Hi-Touch LSI trip unit provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. The Hi-Touch platform provides advanced protection, measurement and monitoring functionality for applications requiring sophisticated power-system supervision and selective coordination, while the LSI configuration focuses protection on overload and short-circuit conditions.

This version is supplied as a withdrawable moving part (WMP) for use with the corresponding Emax 2 fixed part. With an ultimate short-circuit breaking capacity of 85 kA at 415 V AC and 66 kA at 690 V AC, the E2.2S is engineered for substantial industrial, commercial, infrastructure and critical power-distribution duties.

Key Advantages

  • Advanced ABB SACE Emax 2 E2.2S air circuit breaker platform.
  • 1250 A rated uninterrupted current for high-current distribution circuits.
  • Three-pole configuration for three-phase AC power systems.
  • Ekip Hi-Touch LSI electronic trip unit for advanced protection and power-system monitoring.
  • Long-time, short-time delayed and instantaneous short-circuit protection functions.
  • 85 kA ultimate short-circuit breaking capacity at 415 V AC.
  • 66 kA ultimate short-circuit breaking capacity at 690 V AC.
  • Adjustable protection settings support selective coordination within complex distribution networks.
  • Withdrawable construction facilitates inspection, servicing and breaker replacement.
  • Four auxiliary change-over contacts support breaker-status signalling and automation integration.

Key Features

  • ABB SACE Emax 2 E2.2S series.
  • 1250 A rated uninterrupted current.
  • 3-pole circuit-breaker configuration.
  • Ekip Hi-Touch LSI solid-state electronic protection release.
  • Long-time overload protection (L).
  • Short-time delayed short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • 500–1250 A overload release adjustment range.
  • 750–12500 A short-time delayed short-circuit adjustment range.
  • 1875–18750 A instantaneous short-circuit adjustment range.
  • 690 V AC rated voltage.
  • 85 kA Icu at 400–415 V AC.
  • 66 kA Icu at 690 V AC.
  • Withdrawable moving part (WMP) construction.
  • Four auxiliary change-over contacts.
  • Circuit-breaker open/closed position indication.
  • Optional motor drive capability.

Advanced and Selective Protection for Power Distribution

The ABB SACE Emax 2 E2.2S provides dependable protection for high-current low-voltage distribution circuits. Its Ekip Hi-Touch LSI release combines long-time overload protection with short-time delayed and instantaneous short-circuit functions, enabling coordinated fault protection while providing the advanced measurement and monitoring capabilities associated with ABB's Hi-Touch platform.

The E2.2S frame combines strong short-circuit performance with the serviceability of a withdrawable design. The moving part can be separated from the compatible fixed part for inspection, servicing or replacement, while auxiliary contacts and breaker-position indication support integration into switchboard monitoring and automation systems.

Typical Applications

  • Industrial low-voltage power distribution switchboards.
  • Main incomer and high-current feeder protection.
  • Manufacturing and process-industry electrical systems.
  • Commercial building power distribution.
  • Transformer secondary distribution systems.
  • Data centres and critical power infrastructure.
  • Utility and infrastructure electrical installations.
  • Three-phase AC networks requiring advanced selective LSI protection.
  • Withdrawable switchgear requiring sophisticated electronic protection and monitoring.

Technical Specifications

Series SACE Emax 2 E2.2
ABB order code 1SDA072318R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker moving part
Performance level S
Version Withdrawable moving part (WMP)
Number of poles 3
Rated uninterrupted current Iu 1250 A
Rated voltage 690 V AC
Rated ultimate short-circuit breaking capacity Icu at 400–415 V AC 85 kA
Rated ultimate short-circuit breaking capacity Icu at 690 V AC 66 kA
Rated short-time withstand current Icw (1 s) 66 kA
Protection release Ekip Hi-Touch LSI
Release technology Solid-state electronic
Protection functions Long-time overload (L), short-time delayed short circuit (S) and instantaneous short circuit (I)
Overload release setting range 500–1250 A
Short-time delayed short-circuit setting range 750–12500 A
Instantaneous short-circuit setting range 1875–18750 A
Integrated earth-fault protection No
Auxiliary contacts 4 change-over contacts
Breaker position indication Open / closed
Trip indication contact S51
Main-circuit connection Via separate fixed part
Motor drive Optional
Dimensions 317 × 425 × 383 mm
Net weight 48 kg
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA072318R1?

The ABB 1SDA072318R1 is a SACE Emax 2 E2.2S 1250 A three-pole withdrawable air circuit breaker moving part equipped with an Ekip Hi-Touch LSI solid-state electronic protection release.

What protection functions does the Ekip Hi-Touch LSI release provide?

The Ekip Hi-Touch LSI release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. This LSI configuration does not include the integrated earth-fault protection provided by LSIG versions.

What is the rated current of the ABB E2.2S 1SDA072318R1?

The circuit breaker has a rated uninterrupted current of 1250 A, with an overload release setting range of 500–1250 A.

What is the short-circuit performance of the E2.2S 1250?

The E2.2S 1250 provides an ultimate short-circuit breaking capacity of 85 kA at 400–415 V AC and 66 kA at 690 V AC, together with a rated short-time withstand current of 66 kA for 1 s.

Is the ABB 1SDA072318R1 a fixed or withdrawable circuit breaker?

This product is a withdrawable moving part (WMP) designed for use with the corresponding ABB SACE Emax 2 fixed part, which is ordered separately, to form a complete withdrawable air circuit breaker installation.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high-current switching, advanced electronic protection, sophisticated power-system monitoring and flexible withdrawable switchgear integration for dependable protection in demanding low-voltage distribution systems.