1SDA072310R1 ABB E2.2N 1250 Ekip G Hi-Touch LSIG 3p WMP Air Circuit Breaker 1250 A

1SDA072310R1 ABB E2.2N 1250 Ekip G Hi-Touch LSIG 3p WMP Air Circuit Breaker 1250 A

ABB 1SDA072310R1 E2.2N 1250 Ekip G Hi-Touch LSIG 3p WMP is a 1250 A three-pole withdrawable SACE Emax 2 air circuit breaker with generator-focused LSIG protection, advanced power monitoring and 66 kA short-circuit breaking capacity for low-voltage AC systems.

SKU: 1SDA072310R1MPN: 1SDA072310R1
Price
List Price £11,206.56 ex VAT
Your Price (ex VAT) Save 25%
£8,404.92 25% OFF
You save £2,801.64 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,404.92
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,404.92

Why Choose the ABB E2.2N 1250 Ekip G Hi-Touch LSIG 3p WMP Air Circuit Breaker?

The ABB E2.2N 1250 Ekip G Hi-Touch LSIG 3p WMP, order code 1SDA072310R1, is a high-performance three-pole air circuit breaker from the ABB SACE Emax 2 range, designed for demanding low-voltage power distribution and generator protection applications. Rated at 1250 A, it combines the E2.2N frame with ABB's advanced Ekip G Hi-Touch LSIG electronic trip unit for comprehensive overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection.

The Ekip G Hi-Touch platform is specifically equipped for advanced generator protection while also providing sophisticated measurement and network analysis capabilities. Its LSIG protection functions provide four complementary protection stages, while integrated Ekip Measuring Pro and Network Analyzer functionality supports detailed monitoring and analysis of electrical system performance.

With a rated uninterrupted current of 1250 A, rated operational voltage of 690 V AC and rated ultimate short-circuit breaking capacity of 66 kA throughout 400–690 V AC, the 1SDA072310R1 provides robust fault interruption capability for critical electrical installations. Its withdrawable moving-part construction enables installation with a compatible E2.2 fixed part and supports efficient inspection, servicing and replacement within electrical switchboards.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker for generator and low-voltage distribution protection.
  • 1250 A rated uninterrupted current for demanding industrial and infrastructure installations.
  • Three-pole configuration for three-phase AC electrical systems.
  • Ekip G Hi-Touch LSIG electronic trip unit with generator-specific protection functions.
  • LSIG functions provide long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection.
  • 66 kA Icu throughout 400–690 V AC for consistent high fault interruption capability.
  • 66 kA Icw for 1 s and 50 kA for 3 s support selective system coordination.
  • Integrated Ekip Measuring Pro measurement functionality.
  • Integrated Network Analyzer functionality for advanced electrical network monitoring.
  • Withdrawable moving-part construction supports efficient switchgear servicing and maintenance.

Key Features

  • ABB SACE Emax 2 E2.2N series.
  • 1250 A rated current.
  • Three-pole (3P) configuration.
  • Ekip G Hi-Touch LSIG electronic release.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 66 kA rated ultimate short-circuit breaking capacity at 400–690 V AC.
  • 66 kA rated service short-circuit breaking capacity.
  • Ics equal to 100% of Icu.
  • 66 kA rated short-time withstand current for 1 s.
  • 50 kA rated short-time withstand current for 3 s.
  • 0.4–1 × In adjustable long-time overload protection.
  • 0.6–10 × In adjustable short-time protection.
  • 1.5–15 × In adjustable instantaneous protection.
  • 0.1–1 × In adjustable earth-fault protection.
  • Four change-over auxiliary contacts for signalling and control.
  • Suitable for IT networks up to 690 V.
  • Withdrawable moving-part design for compatible ABB Emax 2 switchgear.

Advanced Generator Protection and Network Analysis

The ABB Ekip G Hi-Touch platform is engineered for demanding generator and power distribution applications where sophisticated protection and detailed electrical system monitoring are required. In addition to the fundamental LSIG functions, the trip unit provides generator-specific protection capabilities together with Ekip Measuring Pro and Network Analyzer functionality, helping operators monitor electrical conditions and identify power-quality issues within the network.

Combined with the E2.2N frame, the Ekip G Hi-Touch LSIG release provides comprehensive long-time, short-time delayed, instantaneous and earth-fault protection. Its 66 kA short-circuit breaking capability across the principal 400–690 V AC operating range and substantial short-time withstand ratings make the 1SDA072310R1 particularly suitable for generator incomers, critical distribution boards and installations where protection selectivity and continuity of service are key design requirements.

Typical Applications

  • Generator protection and generator incomer circuits.
  • Power-generation switchboards.
  • Main low-voltage electrical distribution switchboards.
  • Industrial power distribution systems.
  • Critical and standby power systems.
  • Data centre electrical distribution.
  • Manufacturing and process plant switchgear.
  • Infrastructure and utility installations.
  • IT distribution networks up to 690 V.
  • Three-phase AC networks requiring advanced LSIG protection, generator protection and power-quality monitoring.

Technical Specifications

Product range SACE Emax 2
Series E2.2N
Order code / MPN 1SDA072310R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker
Construction Withdrawable moving part
Version W
Number of poles 3P
Rated current (In) 1250 A
Rated uninterrupted current (Iu) 1250 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Frequency 50/60 Hz
Current type AC
Trip unit Ekip G Hi-Touch LSIG
Release type Electronic
Protection functions L (long-time overload), S (short-time delayed short circuit), I (instantaneous short circuit) and G (earth fault)
Application focus Generator and power distribution protection
Short-circuit performance level N
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Rated service short-circuit breaking capacity (Ics) 66 kA
Ics as percentage of Icu 100%
Rated short-time withstand current (Icw) 66 kA for 1 s
Long-time overload protection adjustment 0.4–1 × In
Short-time delayed short-circuit protection adjustment 0.6–10 × In
Instantaneous short-circuit protection adjustment 1.5–15 × In
Earth-fault protection adjustment 0.1–1 × In
Integrated earth-fault protection Yes
Generator-specific protection Yes
Measurement module Ekip Measuring Pro
Network analysis Integrated Network Analyzer functionality
Auxiliary contacts 4 change-over contacts
Position indication Circuit breaker open/closed
Main circuit connection Connection at separate chassis / fixed part
Control element Push button
Motor operator Optional
Integrated motor operator No
Integrated undervoltage release No
DIN rail mounting No
Degree of protection IP30
Connecting capacity 1200 mm²
Power loss 176 W
Mechanical durability 25,000 operating cycles
Electrical durability at Ue ≤ 440 V 15,000 operating cycles
Electrical durability at Ue 500–690 V 15,000 operating cycles
Maximum mechanical operating frequency 60 cycles per hour
Maximum electrical operating frequency 30 cycles per hour
Suitable for IT networks Yes, up to 690 V
Standard IEC 60947-2
Product net weight 48 kg
EAN 8015644761608

Frequently Asked Questions

What is the ABB 1SDA072310R1 used for?

The ABB 1SDA072310R1 is a 1250 A three-pole air circuit breaker designed for demanding low-voltage power distribution and generator protection applications, including generator incomers, industrial switchboards, critical power systems and main distribution boards.

What protection does the Ekip G Hi-Touch LSIG trip unit provide?

The Ekip G Hi-Touch LSIG electronic trip unit provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection. It also provides generator-specific protection functions and advanced measurement and network analysis capabilities.

What is the breaking capacity of the ABB E2.2N 1250?

The E2.2N 1250 has a rated ultimate short-circuit breaking capacity of 66 kA at 400 V, 415 V, 440 V, 500 V and 690 V AC, with rated service short-circuit breaking capacity equal to 100% of Icu.

What makes the Ekip G Hi-Touch suitable for generator applications?

The Ekip G Hi-Touch platform combines LSIG circuit protection with generator-specific protection functions, Ekip Measuring Pro and integrated Network Analyzer functionality, making it suitable for generator incomers and sophisticated power-generation systems requiring advanced monitoring and protection.

Is the ABB 1SDA072310R1 a fixed or withdrawable circuit breaker?

The 1SDA072310R1 is a withdrawable moving part designed for installation with a compatible ABB SACE Emax 2 E2.2 fixed part.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, advanced electronic protection, generator-specific functionality and comprehensive power monitoring for demanding industrial, infrastructure and critical power distribution systems.