Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA072302R1 is a SACE Emax 2 E2.2N 1250 A three-pole withdrawable air circuit breaker moving part with an Ekip Dip LSI electronic trip unit for long-time, short-time and instantaneous protection.
£4,823.71
The ABB 1SDA072302R1 is a SACE Emax 2 E2.2N air circuit breaker designed for reliable protection and switching in demanding low-voltage electrical distribution systems. This three-pole withdrawable moving-part configuration has a rated uninterrupted current of 1250 A and incorporates the Ekip Dip LSI solid-state electronic trip unit.
The Ekip Dip LSI release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. Its adjustable protection functions allow the breaker to be coordinated with downstream protective devices, making it suitable for industrial, commercial, transformer, generator and infrastructure distribution systems where selective overcurrent protection is required.
The E2.2N 1250 provides a rated ultimate short-circuit breaking capacity of 66 kA at 400 V AC, with the E2.2N platform maintaining 66 kA breaking capability through 690 V AC. The withdrawable moving-part design connects to a separate chassis part, supporting efficient inspection, servicing and replacement in compatible ABB SACE Emax 2 switchgear.
The ABB Emax 2 E2.2N combines high-current switching with adjustable electronic protection for complex low-voltage networks. Its Ekip Dip LSI release protects against sustained overloads, provides a short-time delayed response for selective short-circuit coordination and delivers instantaneous operation against severe fault currents, helping protect cables, busbars, switchgear and connected equipment.
The adjustable short-time function makes this LSI configuration particularly useful where coordination between upstream and downstream protection devices is required. Combined with the E2.2N's 66 kA breaking capability and withdrawable architecture, the 1SDA072302R1 provides a maintainable protection solution for demanding industrial and commercial electrical distribution systems.
| Series | SACE Emax 2 |
|---|---|
| Frame | E2.2 |
| Performance level | N |
| ABB order code | 1SDA072302R1 |
| Product type | Air circuit breaker |
| Configuration | Withdrawable moving part |
| Rated uninterrupted current | 1250 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage | 1000 V AC |
| Rated impulse withstand voltage | 12 kV |
| Frequency | 50/60 Hz |
| Number of poles | 3 |
| Trip unit | Ekip Dip LSI |
| Release type | Solid-state electronic release |
| Protection functions | Long-time, short-time and instantaneous (LSI) |
| Overload protection adjustment | 0.4–1 × In |
| Short-time protection adjustment | 0.6–10 × In |
| Instantaneous protection adjustment | 1.5–15 × In |
| Integrated earth-fault protection | No |
| Rated ultimate short-circuit breaking capacity | 66 kA at 400 V AC |
| Rated service short-circuit breaking capacity | 66 kA at 400 V AC |
| Main circuit connection | Connection at separate chassis part |
| Connecting capacity | 1200 mm² |
| Auxiliary contacts | 4 change-over contacts |
| Switched-off indication | Yes |
| Operating element | Push button |
| Protection unit | Included |
| Integrated motor operator | No |
| Optional motor operator | Yes |
| Integrated undervoltage release | No |
| Protection rating | IP30 |
| Electrical durability | 15,000 operating cycles |
| Mechanical durability | 25,000 operating cycles |
| Power loss | 176 W |
| Dimensions (W × H × D) | 317 × 425 × 383 mm |
| Weight | 48 kg |
| EAN | 8015644761523 |
The ABB 1SDA072302R1 is an Emax 2 air circuit breaker designed for switching and protecting high-current low-voltage electrical distribution systems.
The E2.2N 1250 has a rated uninterrupted current of 1250 A.
The Ekip Dip LSI electronic release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.
The E2.2N 1250 has a rated ultimate short-circuit breaking capacity of 66 kA at 400 V AC.
No. This configuration uses an LSI protection release providing long-time, short-time and instantaneous protection without integrated earth-fault protection.
Yes. The 1SDA072302R1 is supplied as the moving part of a withdrawable SACE Emax 2 circuit breaker and connects to the appropriate separate chassis part.
ABB SACE Emax 2 air circuit breakers are engineered for reliable protection and control of demanding low-voltage electrical distribution systems, combining adjustable electronic protection, high short-circuit performance and maintainable withdrawable construction for industrial, commercial and infrastructure switchgear.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.