1SDA072272R1 ABB E2.2N 1000 Ekip Dip LSI 3p WMP Air Circuit Breaker 1000 A

1SDA072272R1 ABB E2.2N 1000 Ekip Dip LSI 3p WMP Air Circuit Breaker 1000 A

ABB 1SDA072272R1 E2.2N 1000 Ekip Dip LSI 3p WMP is a 1000 A three-pole withdrawable SACE Emax 2 air circuit breaker with electronic LSI protection and 66 kA short-circuit breaking capacity for low-voltage AC power distribution systems.

SKU: 1SDA072272R1MPN: 1SDA072272R1
Price
List Price £6,158.75 ex VAT
Your Price (ex VAT) Save 25%
£4,619.06 25% OFF
You save £1,539.69 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,619.06
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,619.06

Why Choose the ABB E2.2N 1000 Ekip Dip LSI 3p WMP Air Circuit Breaker?

The ABB E2.2N 1000 Ekip Dip LSI 3p WMP, order code 1SDA072272R1, is a high-performance three-pole air circuit breaker from the ABB SACE Emax 2 range, designed for protection and switching in low-voltage electrical distribution systems. Rated at 1000 A, it combines the E2.2N frame with ABB's solid-state Ekip Dip LSI electronic trip unit for dependable long-time overload, short-time delayed and instantaneous short-circuit protection.

The Ekip Dip LSI release provides three fundamental protection functions for effective coordination within industrial and commercial power networks. Long-time protection safeguards against sustained overloads, short-time delayed protection supports selectivity between upstream and downstream protective devices, and instantaneous protection responds rapidly to severe short-circuit faults.

With a rated uninterrupted current of 1000 A, rated operational voltage of 690 V AC and rated ultimate short-circuit breaking capacity of 66 kA at 400 V AC, the 1SDA072272R1 is suited to demanding power distribution applications. Its withdrawable moving-part construction enables installation with a compatible Emax 2 E2.2 fixed part and facilitates inspection, servicing and replacement within electrical switchboards.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for low-voltage power distribution.
  • 1000 A rated uninterrupted current for demanding industrial and commercial installations.
  • Three-pole configuration for three-phase AC distribution systems.
  • Ekip Dip LSI electronic trip unit providing overload and two-stage short-circuit protection.
  • 66 kA rated ultimate short-circuit breaking capacity at 400 V AC.
  • 400–1000 A adjustable overload release range.
  • 600–10000 A adjustable short-time delayed short-circuit release range.
  • Withdrawable moving-part construction supports efficient switchgear servicing and maintenance.

Key Features

  • ABB SACE Emax 2 E2.2N series.
  • 1000 A rated current.
  • Three-pole (3P) configuration.
  • Ekip Dip LSI solid-state electronic release.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 66 kA Icu at 400 V AC, 50 Hz.
  • 66 kA Ics across 220–440 V AC.
  • 400–1000 A adjustable overload release range.
  • 600–10000 A adjustable short-time delayed short-circuit release range.
  • 1500–15000 A adjustable instantaneous short-circuit release range.
  • Four change-over auxiliary contacts for signalling and control.
  • Withdrawable moving-part design for compatible ABB Emax 2 switchgear.

Selective Protection for Low-Voltage Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 provide switching and protection for high-current low-voltage distribution circuits. The E2.2N combines substantial short-circuit interruption capability with electronic protection, helping safeguard cables, busbars, switchgear and connected equipment against damaging overload and short-circuit conditions.

The Ekip Dip LSI release combines long-time overload protection with short-time delayed and instantaneous short-circuit protection. The short-time delay function enables improved coordination between protective devices, helping isolate a fault at the appropriate point in the distribution network while maintaining supply to unaffected circuits where the system has been designed for selectivity.

Typical Applications

  • Main low-voltage electrical distribution switchboards.
  • Industrial power distribution systems.
  • Transformer and installation protection.
  • Commercial building electrical infrastructure.
  • Manufacturing and process plant switchgear.
  • Critical power distribution systems.
  • Infrastructure and utility installations.
  • Three-phase AC distribution networks requiring selective LSI protection.

Technical Specifications

Product range SACE Emax 2
Series E2.2N
Order code / MPN 1SDA072272R1
Product type Air circuit breaker
Construction Withdrawable moving part
Version W
Number of poles 3P
Rated current (In) 1000 A
Rated uninterrupted current (Iu) 1000 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Current type AC
Trip unit Ekip Dip LSI
Release type Solid-state electronic
Protection functions L (long-time overload), S (short-time delayed short circuit) and I (instantaneous short circuit)
Short-circuit performance level N
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC, 50 Hz 66 kA
Rated service short-circuit breaking capacity (Ics) at 220–440 V AC 66 kA
Overload release adjustment range 400–1000 A
Short-time delayed short-circuit release adjustment range 600–10000 A
Instantaneous short-circuit release adjustment range 1500–15000 A
Integrated earth-fault protection No
Auxiliary contacts 4 change-over contacts
Position indication Circuit breaker open/closed
Main circuit connection Separate chassis / fixed part
Control element Push button
Motor operator Optional
Integrated motor operator No
Integrated undervoltage release No
DIN rail mounting No
Degree of protection IP30
Connecting capacity 600 mm²
Power loss 113 W
Mechanical durability 25,000 operating cycles
Electrical durability at Ue ≤ 440 V 15,000 operating cycles
Electrical durability at Ue 500–690 V 15,000 operating cycles
Maximum mechanical operating frequency 60 cycles per hour
Maximum electrical operating frequency 30 cycles per hour
Product net weight approx. 48 kg
Standard IEC 60947-2
EAN 8015644761226

Frequently Asked Questions

What is the ABB 1SDA072272R1 used for?

The ABB 1SDA072272R1 is a 1000 A three-pole air circuit breaker used for switching and protecting low-voltage AC power distribution circuits in industrial, commercial and infrastructure electrical systems.

What protection does the Ekip Dip LSI trip unit provide?

The Ekip Dip LSI solid-state electronic trip unit provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.

What is the breaking capacity of the ABB E2.2N 1000?

The E2.2N 1000 has a rated ultimate short-circuit breaking capacity of 66 kA at 400 V AC, 50 Hz.

What are the adjustable protection ranges of the Ekip Dip LSI?

The overload release can be adjusted from 400–1000 A, the short-time delayed short-circuit release from 600–10000 A, and the instantaneous short-circuit release from 1500–15000 A.

Is the ABB 1SDA072272R1 a fixed or withdrawable circuit breaker?

The 1SDA072272R1 is a withdrawable moving part designed for installation with a compatible ABB SACE Emax 2 E2.2 fixed part.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, configurable electronic protection and service-friendly withdrawable construction for demanding industrial, commercial and infrastructure power distribution systems.