1SDA072252R1 ABB E2.2S 800 Ekip Dip LSI 3p WMP Air Circuit Breaker

1SDA072252R1 ABB E2.2S 800 Ekip Dip LSI 3p WMP Air Circuit Breaker

ABB 1SDA072252R1 SACE Emax 2 E2.2S 800 A three-pole withdrawable air circuit breaker moving part with Ekip Dip LSI electronic overload and short-circuit protection.

SKU: 1SDA072252R1MPN: 1SDA072252R1
Price
List Price £6,782.40 ex VAT
Your Price (ex VAT) Save 25%
£5,086.80 25% OFF
You save £1,695.60 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,086.80
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,086.80

Why Choose the ABB E2.2S 800 Ekip Dip LSI 3p WMP Air Circuit Breaker?

The ABB E2.2S 800 Ekip Dip LSI 3p WMP, order code 1SDA072252R1, is a high-performance SACE Emax 2 air circuit breaker moving part designed for protection and switching in low-voltage AC power distribution systems. As part of the ABB Emax 2 E2.2 series, this three-pole breaker combines an 800 A rated current with the Ekip Dip LSI electronic protection release.

The integrated Ekip Dip LSI trip unit provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. This combination enables selective and configurable protection of electrical distribution circuits while helping coordinate the breaker with upstream and downstream protective devices.

This E2.2S version is a withdrawable moving part (WMP) for use with the corresponding Emax 2 fixed part. With a rated operational voltage of 690 V AC, an ultimate short-circuit breaking capacity of 85 kA at 400 V AC and robust withdrawable construction, it is suited to demanding industrial, commercial and infrastructure power-distribution installations.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for low-voltage power distribution.
  • 800 A rated current for substantial industrial and commercial electrical loads.
  • Three-pole configuration for three-phase AC distribution systems.
  • Ekip Dip LSI electronic trip unit for configurable circuit protection.
  • Long-time, short-time and instantaneous protection functions.
  • 85 kA ultimate short-circuit breaking capacity at 400 V AC.
  • Withdrawable construction supports efficient inspection, servicing and switchboard maintenance.
  • Four auxiliary change-over contacts support breaker status signalling and control integration.

Key Features

  • ABB SACE Emax 2 E2.2S series.
  • 800 A rated current.
  • 3-pole circuit-breaker configuration.
  • Ekip Dip LSI solid-state electronic protection release.
  • Long-time overload protection (L).
  • Short-time delayed short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Withdrawable moving part (WMP) construction.
  • Four auxiliary change-over contacts.
  • Switched-off position indication.
  • Optional motor drive capability.

Reliable and Selective Protection for Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 protect high-current electrical distribution circuits against overload and short-circuit conditions. The Ekip Dip LSI release combines long-time overload protection with short-time delayed and instantaneous short-circuit functions, allowing protection settings to be coordinated with other devices in the distribution network.

The E2.2S frame is designed for installations requiring high breaking and short-time withstand performance. Its withdrawable construction enables the moving part to be separated from the compatible fixed switchboard section for maintenance or replacement, while auxiliary contacts and breaker status indication support integration with electrical control and monitoring systems.

Typical Applications

  • Industrial low-voltage power distribution switchboards.
  • Main incomer and feeder circuit protection.
  • Manufacturing and process-industry electrical systems.
  • Commercial building power distribution.
  • Transformer secondary distribution systems.
  • Infrastructure and utility electrical installations.
  • High-fault-level three-phase distribution networks.
  • Withdrawable switchgear requiring selective LSI protection.

Technical Specifications

Series SACE Emax 2 E2.2
ABB order code 1SDA072252R1
Product type Air circuit breaker moving part
Version Withdrawable (WMP)
Number of poles 3
Rated current 800 A
Current type AC
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V AC
Rated impulse withstand voltage 12 kV
Rated ultimate short-circuit breaking capacity Icu at 400 V, 50 Hz 85 kA
Rated short-time withstand current Icw (1 s) 66 kA
Protection release Ekip Dip LSI
Release technology Solid-state electronic
Protection functions Long-time overload (L), short-time short circuit (S) and instantaneous short circuit (I)
Integrated earth-fault protection No
Auxiliary contacts 4 change-over contacts
Operating control Push button
Motor drive Optional
Protection rating IP30
Power loss 72 W
Mechanical durability 25,000 operating cycles
Electrical durability 15,000 operating cycles
Dimensions (W × H × D) 317 × 425 × 383 mm
Net weight 48 kg
EAN 8015644761028

Frequently Asked Questions

What is the ABB 1SDA072252R1?

The ABB 1SDA072252R1 is a SACE Emax 2 E2.2S 800 A three-pole withdrawable air circuit breaker moving part equipped with an Ekip Dip LSI electronic protection release.

What protection functions does the Ekip Dip LSI release provide?

The Ekip Dip LSI release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.

What is the rated current of the ABB E2.2S 1SDA072252R1?

The circuit breaker has a rated current of 800 A, making it suitable for substantial industrial and commercial low-voltage distribution loads.

What is the short-circuit performance of the E2.2S 800?

The E2.2S 800 provides a rated ultimate short-circuit breaking capacity of 85 kA at 400 V AC, 50 Hz and a rated short-time withstand current of 66 kA for 1 s.

Is the ABB 1SDA072252R1 a fixed or withdrawable circuit breaker?

This product is the withdrawable moving part (WMP) and is designed for use with the corresponding ABB SACE Emax 2 fixed part in a complete withdrawable circuit-breaker installation.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high-current switching, configurable electronic protection and flexible withdrawable switchgear integration to provide dependable and selective protection for demanding industrial, commercial and infrastructure power-distribution systems.