Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA072226R1 Emax 2 E1.2C 1600 three-pole withdrawable air circuit breaker moving part with a 1600 A rated current, 50 kA breaking capacity at 400 V AC and Ekip Touch LSIG electronic protection.
£4,092.84
The ABB E1.2C 1600 Ekip Touch LSIG 3p WMP, order code 1SDA072226R1, is a withdrawable Emax 2 air circuit breaker (ACB) moving part designed for advanced protection, switching and isolation in low-voltage electrical distribution systems. Part of the ABB SACE Emax 2 series, this three-pole unit combines a 1600 A rated current with the Ekip Touch LSIG electronic trip unit for comprehensive overload, short-circuit and ground-fault protection.
The compact E1.2C platform provides high short-circuit performance for demanding industrial, commercial and infrastructure switchboards. Its Ekip Touch LSIG electronic release provides long-time, short-time, instantaneous and ground-fault protection, supporting selective coordination while providing protection against the principal overcurrent and earth-fault conditions encountered in low-voltage distribution systems.
With a 1600 A rated current, a three-pole configuration and an ultimate short-circuit breaking capacity of 50 kA at 400 V AC, the E1.2C 1600 provides dependable protection for high-current distribution circuits. The WMP withdrawable moving-part configuration connects through the corresponding separate Emax 2 chassis or fixed part, supporting convenient isolation, testing and maintenance.
The ABB Emax 2 E1.2C combines high-current switching with intelligent electronic protection for important low-voltage distribution circuits. Its 1600 A current rating and 50 kA ultimate short-circuit breaking capacity at 400 V AC make it suitable for incoming supplies, distribution feeders and other circuits where dependable fault interruption, selectivity and continuity of supply are important.
The Ekip Touch LSIG trip unit provides four complementary protection functions. Long-time protection responds to sustained overloads, short-time protection enables controlled fault clearing and selective coordination, instantaneous protection rapidly interrupts severe short circuits, and ground-fault protection responds to earth-fault conditions. Combined with the Ekip Touch interface and withdrawable Emax 2 construction, these functions provide an intelligent and maintainable solution for modern low-voltage switchboards.
| Product group | Emax2 Air Circuit Breaker |
|---|---|
| Series | SACE Emax 2 |
| ABB order code | 1SDA072226R1 |
| EAN | 8015644760762 |
| Product type | Air circuit breaker moving part |
| Frame | E1.2 |
| Performance level | C |
| Rated current | 1600 A |
| Number of poles | 3 |
| Current type | AC |
| Ultimate short-circuit breaking capacity (Icu) | 50 kA at 400 V AC, 50 Hz |
| Trip unit | Ekip Touch LSIG |
| Release type | Electronic / solid-state |
| Protection functions | Long-time, short-time, instantaneous and ground fault (LSIG) |
| Long-time overload protection range | 640–1600 A |
| Instantaneous protection adjustment | 2400–24000 A |
| Ground-fault protection | Integrated |
| Execution | Withdrawable moving part (WMP) |
| Main-circuit connection | Connection at separate chassis part |
| Auxiliary contacts | 4 change-over contacts |
| Switched-off indication | Yes |
| Integrated undervoltage release | No |
| Integrated motor drive | No |
| Optional motor drive | Yes |
| Degree of protection | IP30 |
| Country of origin | Italy |
| Application | Low-voltage power distribution and selective circuit protection |
The ABB 1SDA072226R1 is an Emax 2 air circuit breaker moving part designed for switching and protecting three-phase low-voltage electrical distribution circuits in industrial, commercial and infrastructure switchboards.
The circuit breaker has a rated current of 1600 A, with long-time overload protection adjustable across 640–1600 A.
The breaker uses an Ekip Touch LSIG electronic trip unit providing long-time, short-time, instantaneous and ground-fault protection, together with a touch interface for configuration and monitoring.
The ABB E1.2C 1600 1SDA072226R1 has an ultimate short-circuit breaking capacity of 50 kA at 400 V AC, 50 Hz.
WMP identifies the withdrawable moving part of the circuit breaker. Its main circuit connects through the corresponding separate Emax 2 chassis or fixed part, allowing the moving part to be withdrawn for isolation, testing and maintenance.
ABB SACE Emax 2 air circuit breakers combine high-performance low-voltage circuit protection with intelligent electronic trip technology, selective coordination, integrated ground-fault protection and flexible withdrawable switchgear integration for modern industrial and commercial power distribution systems.
We use cookies