1SDA072200R1 ABB Emax 2 E1.2N 1250 Ekip G Hi-Touch LSIG 3-Pole Withdrawable Air Circuit Breaker

1SDA072200R1 ABB Emax 2 E1.2N 1250 Ekip G Hi-Touch LSIG 3-Pole Withdrawable Air Circuit Breaker

ABB 1SDA072200R1 is an Emax 2 E1.2N 1250 A three-pole withdrawable air circuit breaker moving part with an Ekip G Hi-Touch LSIG electronic trip unit for advanced generator, overload, short-circuit and earth-fault protection.

SKU: 1SDA072200R1MPN: 1SDA072200R1
Price
List Price £10,954.33 ex VAT
Your Price (ex VAT) Save 25%
£8,215.75 25% OFF
You save £2,738.58 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,215.75
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,215.75

Why Choose the ABB 1SDA072200R1 Emax 2 Air Circuit Breaker?

The ABB 1SDA072200R1 is a high-performance SACE Emax 2 E1.2N air circuit breaker designed for protection, switching and isolation in demanding low-voltage generator and electrical distribution systems. This three-pole withdrawable circuit breaker moving part has a rated uninterrupted current of 1250 A and incorporates an advanced Ekip G Hi-Touch LSIG solid-state electronic trip unit providing long-time, short-time, instantaneous and earth-fault protection.

The E1.2N performance level combines the compact E1.2 frame with high short-circuit capability. This configuration provides an ultimate short-circuit breaking capacity of 66 kA at 400 V AC, 50 Hz, making it suitable for demanding industrial, commercial, infrastructure and generator applications where high-performance circuit protection is required.

The E1.2N 1250 Ekip G Hi-Touch LSIG 3p WMP is supplied as the moving part of a withdrawable circuit-breaker system and connects to the main circuit through a compatible separate fixed chassis. Its generator-oriented Ekip G Hi-Touch release, comprehensive LSIG protection and withdrawable construction make it particularly suitable for generator switchboards, main incomers, transformer secondary circuits and critical distribution feeders.

Key Advantages

  • 1250 A Emax 2 air circuit breaker for demanding generator and low-voltage distribution systems.
  • Three-pole configuration for three-phase electrical installations.
  • Ekip G Hi-Touch LSIG electronic trip unit provides advanced generator-oriented protection.
  • Long-time, short-time, instantaneous and earth-fault protection in a single electronic release.
  • Ultimate short-circuit breaking capacity of 66 kA at 400 V AC, 50 Hz.
  • Withdrawable moving-part execution facilitates isolation, inspection and maintenance.

Key Features

  • ABB SACE Emax 2 E1.2N series.
  • 1250 A rated uninterrupted current.
  • Three-pole construction.
  • Ekip G Hi-Touch LSIG solid-state electronic protection release.
  • Long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection functions.
  • Generator-oriented Ekip G protection functionality.
  • 690 V rated voltage.
  • 66 kA ultimate short-circuit breaking capacity at 400 V AC, 50 Hz.
  • Withdrawable moving-part configuration with connection through a compatible separate chassis.
  • Four change-over auxiliary contacts for circuit-breaker status signalling.
  • Open/closed circuit-breaker position indication.
  • Optional motor drive capability.
  • IP30 degree of protection.

Advanced Generator and LSIG Protection for Low-Voltage Systems

The ABB Ekip G Hi-Touch LSIG electronic trip unit combines advanced generator-oriented functionality with long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection. Its adjustable settings allow the E1.2N circuit breaker to protect generators, cables, busbars, transformers and downstream equipment while supporting coordinated protection across demanding low-voltage networks.

The withdrawable E1.2N platform is particularly useful in switchboards where serviceability and operational flexibility are important. The circuit breaker moving part connects to the main circuit through a compatible separate chassis and can be withdrawn for inspection or maintenance while the permanent switchboard connections remain installed.

Typical Applications

  • Generator protection and generator switchboards.
  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Transformer secondary and incomer protection.
  • Critical distribution feeder protection.
  • Commercial, infrastructure and process-industry switchgear.

Technical Specifications

Series SACE Emax 2
ABB order code 1SDA072200R1
EAN / GTIN 8015644760502
Product type Air circuit breaker
Frame E1.2
Performance level N
Rated uninterrupted current 1250 A
Rated voltage 690 V
Number of poles 3
Trip unit Ekip G Hi-Touch LSIG
Release technology Solid-state electronic
Protection functions L, S, I, G
Overload release current setting 500–1250 A
Short-time delayed short-circuit release setting 750–12,500 A
Instantaneous short-circuit release setting 1875–18,750 A
Integrated earth-fault protection Yes
Ultimate short-circuit breaking capacity 66 kA at 400 V AC, 50 Hz
Execution Withdrawable moving part
Main circuit connection Through compatible separate fixed chassis
Auxiliary contacts 4 change-over contacts
Circuit-breaker indication Open / closed position
Operating element Push button
Integrated undervoltage release No
Integrated motor drive No
Optional motor drive Yes
Degree of protection IP30
Product weight 20 kg
Country of origin Italy

Frequently Asked Questions

What is the ABB 1SDA072200R1?

The ABB 1SDA072200R1 is an Emax 2 E1.2N three-pole withdrawable air circuit breaker moving part rated at 1250 A and equipped with an Ekip G Hi-Touch LSIG solid-state electronic trip unit.

What protection functions does the Ekip G Hi-Touch LSIG trip unit provide?

The Ekip G Hi-Touch LSIG release provides long-time (L), short-time (S), instantaneous (I) and earth-fault (G) protection together with advanced generator-oriented functionality.

What is the breaking capacity of the ABB E1.2N 1250?

The ABB E1.2N 1250 configuration provides an ultimate short-circuit breaking capacity of 66 kA at 400 V AC, 50 Hz.

Is the ABB 1SDA072200R1 fixed or withdrawable?

The 1SDA072200R1 is a withdrawable moving-part air circuit breaker designed to connect through a compatible separate ABB Emax 2 fixed chassis.

Does the ABB 1SDA072200R1 provide earth-fault protection?

Yes. Its Ekip G Hi-Touch LSIG electronic trip unit includes earth-fault protection in addition to long-time, short-time and instantaneous overcurrent protection.

Trusted by Electrical Distribution Professionals Worldwide

ABB Emax 2 air circuit breakers are widely specified for generator, industrial, commercial and infrastructure electrical systems where dependable switching, advanced electronic protection, high short-circuit performance and maintainable low-voltage distribution equipment are required.