ABB 1SDA072197R1 E1.2N 1250 Ekip G Touch LSIG three-pole moving part for a withdrawable SACE Emax 2 air circuit breaker, rated at 1250 A and 690 V AC with generator-oriented LSIG electronic protection and 66 kA ultimate short-circuit breaking capacity at 415 V AC.

SKU: 1SDA072197R1MPN: 1SDA072197R1
Price
List Price £10,131.75 ex VAT
Your Price (ex VAT) Save 25%
£7,598.81 25% OFF
You save £2,532.94 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,598.81
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,598.81

Why Choose the ABB E1.2N 1250 Ekip G Touch LSIG 3p WMP Air Circuit Breaker Moving Part?

The ABB E1.2N 1250 Ekip G Touch LSIG 3p WMP, order code 1SDA072197R1, is the three-pole moving part of a withdrawable SACE Emax 2 air circuit breaker, engineered for advanced generator and low-voltage power-system protection. Rated at 1250 A, it combines the compact E1.2N frame with ABB's generator-oriented Ekip G Touch electronic protection technology.

The Ekip G Touch LSIG electronic trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection. The Ekip G Touch platform is specifically suited to generator applications and combines protection with measurement and monitoring functions through an intuitive touchscreen interface.

As a WMP moving part, the 1SDA072197R1 is designed for installation with the corresponding ABB Emax 2 withdrawable fixed part. The E1.2N performance level provides an ultimate short-circuit breaking capacity of 66 kA at 415 V AC and 50 kA at 690 V AC, providing robust fault interruption for demanding generator, industrial and critical-power installations.

Key Advantages

  • 1250 A three-pole Emax 2 moving part for withdrawable air circuit breaker installations.
  • Ekip G Touch LSIG provides generator-oriented electronic protection and monitoring.
  • Long-time, short-time, instantaneous and ground-fault protection in one trip unit.
  • 66 kA ultimate short-circuit breaking capacity at 415 V AC.
  • 50 kA ultimate short-circuit breaking capacity at 690 V AC.
  • 500–1250 A adjustable long-time protection range supports application-specific coordination.
  • Touchscreen interface simplifies protection configuration and access to electrical information.
  • Withdrawable construction supports efficient inspection, servicing and breaker replacement.
  • Compatible with ABB Emax 2 automation, communication and energy-management architecture.

Key Features

  • ABB SACE Emax 2 E1.2N series.
  • 1250 A rated current.
  • Three-pole configuration.
  • Withdrawable moving-part construction.
  • Ekip G Touch LSIG solid-state electronic release.
  • Long-time overload (L) protection.
  • Short-time short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • Integrated ground-fault (G) protection.
  • Generator-oriented protection functionality.
  • 500–1250 A long-time protection setting range.
  • 1.5–15 × In instantaneous protection setting range.
  • 690 V AC rated voltage.
  • 66 kA Icu at 415 V AC.
  • 50 kA Icu at 690 V AC.
  • Four auxiliary contacts and circuit-breaker open/closed position indication.

Advanced Generator and Power-System Protection

Generator-fed electrical systems can require protection functions tailored to operating conditions that differ from conventional utility-fed networks. The ABB Ekip G Touch platform addresses these requirements by combining LSIG circuit protection with generator-oriented functions, electrical measurement and touchscreen-based configuration in a single electronic release.

Combined with the E1.2N frame's 1250 A rating, 66 kA ultimate breaking capacity at 415 V AC and 50 kA capability at 690 V AC, the 1SDA072197R1 provides a high-performance protection platform for generator incomers and critical distribution systems. Its withdrawable design also enables the breaker moving part to be removed from the fixed chassis for inspection, servicing or replacement.

Typical Applications

  • Generator protection and generator switchboards.
  • Emergency and standby generating systems.
  • Industrial power-generation installations.
  • Low-voltage main distribution switchboards.
  • Critical power and infrastructure systems.
  • Data centres and high-availability electrical installations.
  • Manufacturing and process plant power systems.
  • Incoming and high-current feeder protection.
  • Withdrawable switchgear requiring advanced LSIG protection.

Technical Specifications

Series SACE Emax 2
ABB order code 1SDA072197R1
Product type Air circuit breaker moving part
Frame E1.2
Performance level N
Rated current 1250 A
Number of poles 3
Version Withdrawable moving part (WMP)
Trip unit Ekip G Touch LSIG
Release technology Solid-state electronic
Protection functions Long-time (L), short-time (S), instantaneous (I) and ground-fault (G)
Generator-oriented protection Yes
Long-time protection adjustment 0.4–1 × In (500–1250 A)
Instantaneous protection adjustment 1.5–15 × In
Rated operational voltage 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 50 kA
Auxiliary contacts 4
Circuit-breaker position indication Open/closed
User interface Touchscreen
Product dimensions 363.5 × 271 × 271 mm
EAN / GTIN 8015644760472
Country of origin Italy
Reference standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA072197R1?

The ABB 1SDA072197R1 is the 1250 A three-pole moving part of a SACE Emax 2 E1.2N withdrawable air circuit breaker, equipped with an Ekip G Touch LSIG solid-state electronic trip unit.

What protection does the Ekip G Touch LSIG trip unit provide?

The Ekip G Touch LSIG release provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and integrated ground-fault (G) protection, together with generator-oriented protection capabilities.

What is the breaking capacity of the ABB E1.2N 1250?

The E1.2N 1250 provides an ultimate short-circuit breaking capacity of 66 kA at 415 V AC and 50 kA at 690 V AC.

Is the ABB 1SDA072197R1 suitable for generator protection?

Yes. The Ekip G Touch platform is designed for generator-oriented applications and combines LSIG circuit protection with additional generator protection, measurement and monitoring capabilities.

Is the ABB 1SDA072197R1 fixed or withdrawable?

The 1SDA072197R1 is the moving part of a withdrawable air circuit breaker and is intended for installation with the corresponding ABB Emax 2 fixed part.

Advanced Protection for Critical Generator Systems

ABB SACE Emax 2 circuit breakers with Ekip G Touch protection combine generator-oriented functionality, comprehensive electronic protection and service-friendly withdrawable construction for dependable control of critical low-voltage power systems.