ABB 1SDA072192R1 E1.2N 1250 Ekip Dip LSI 3p WMP is a 1250 A three-pole withdrawable SACE Emax 2 air circuit breaker with electronic LSI protection for low-voltage power distribution systems.
£4,709.77
The ABB E1.2N 1250 Ekip Dip LSI 3p WMP, order code 1SDA072192R1, is a high-performance three-pole air circuit breaker from the ABB SACE Emax 2 range, designed for protection and switching in low-voltage electrical distribution systems. Rated at 1250 A, it combines the compact E1.2 frame with ABB's electronic Ekip Dip LSI trip unit for dependable overload, short-time delayed and instantaneous short-circuit protection.
This Emax 2 circuit breaker is supplied as a withdrawable moving part for integration with a compatible E1.2 fixed part in switchgear assemblies. The E1.2N performance level provides a rated ultimate short-circuit breaking capacity of 66 kA at 400 V AC, making the breaker suitable for demanding industrial, commercial and infrastructure power distribution applications.
With a rated uninterrupted current of 1250 A and a rated operational voltage of 690 V AC, the 1SDA072192R1 provides robust protection for high-current low-voltage installations. Its Ekip Dip LSI electronic release adds adjustable short-time delayed protection to the standard long-time and instantaneous functions, providing greater selectivity and coordination within complex electrical distribution networks.
Air circuit breakers such as the ABB SACE Emax 2 provide switching and protection for high-current low-voltage distribution circuits. By detecting overload and short-circuit conditions, the electronic trip unit can initiate circuit interruption to help protect cables, switchgear and connected electrical equipment from damaging fault currents.
The Ekip Dip LSI release combines long-time overload protection with adjustable short-time delayed and instantaneous short-circuit protection. The additional short-time protection function supports selective coordination between protective devices, helping isolate faults at the appropriate point in a distribution network while maintaining supply to unaffected circuits wherever the system design permits.
| Product range | SACE Emax 2 |
|---|---|
| Series | E1.2N |
| Order code / MPN | 1SDA072192R1 |
| Product type | Air circuit breaker |
| Construction | Withdrawable moving part |
| Number of poles | 3P |
| Rated uninterrupted current (Iu) | 1250 A |
| Rated operational voltage | 690 V AC |
| Current type | AC |
| Trip unit | Ekip Dip LSI |
| Release type | Solid-state electronic |
| Protection functions | L (overload), S (short-time delayed short circuit) and I (instantaneous short circuit) |
| Short-circuit performance level | N |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC, 50 Hz | 66 kA |
| Rated short-time withstand current (Icw) for 1 s | 50 kA |
| Overload release adjustment range | 500–1250 A |
| Short-time delayed short-circuit release adjustment range | 750–12500 A |
| Instantaneous short-circuit release adjustment range | 1875–18750 A |
| Integrated earth fault protection | No |
| Auxiliary contacts | 4 change-over contacts |
| Trip indication | Yes |
| Motor operator | Optional |
| Integrated motor operator | No |
| Integrated undervoltage release | No |
| DIN rail mounting | No |
| Power loss | 244 W |
| Mechanical durability | 20,000 operating cycles |
| Electrical durability at Ue ≤ 440 V | 8,000 operating cycles |
| Electrical durability at Ue 500–690 V | 6,500 operating cycles |
| EAN | 8015644760427 |
The ABB 1SDA072192R1 is a 1250 A three-pole air circuit breaker used for switching and protecting low-voltage electrical distribution circuits in industrial, commercial and infrastructure installations.
The Ekip Dip LSI electronic trip unit provides long-time overload protection, short-time delayed short-circuit protection and instantaneous short-circuit protection.
The E1.2N breaker has a rated ultimate short-circuit breaking capacity of 66 kA at 400 V AC, 50 Hz.
The overload release can be adjusted from 500–1250 A, the short-time delayed short-circuit release from 750–12500 A, and the instantaneous short-circuit release from 1875–18750 A.
The 1SDA072192R1 is the withdrawable moving part of the Emax 2 circuit breaker system and is designed for use with a compatible E1.2 fixed part.
ABB SACE Emax 2 air circuit breakers are engineered for dependable protection and control of low-voltage power distribution systems, combining high interruption performance, configurable electronic protection and service-friendly construction for demanding electrical installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.