1SDA072184R1 ABB E1.2C 1250 Ekip Touch LI 3p WMP Air Circuit Breaker Moving Part

1SDA072184R1 ABB E1.2C 1250 Ekip Touch LI 3p WMP Air Circuit Breaker Moving Part

ABB 1SDA072184R1 E1.2C 1250 Ekip Touch LI three-pole moving part for a withdrawable SACE Emax 2 air circuit breaker, rated at 1250 A and 690 V AC with adjustable electronic LI protection and 50 kA ultimate short-circuit breaking capacity at 400 V AC.

SKU: 1SDA072184R1MPN: 1SDA072184R1
Price
List Price £3,872.14 ex VAT
Your Price (ex VAT) Save 25%
£2,904.11 25% OFF
You save £968.04 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,904.11
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,904.11

Why Choose the ABB E1.2C 1250 Ekip Touch LI 3p WMP Air Circuit Breaker Moving Part?

The ABB E1.2C 1250 Ekip Touch LI 3p WMP, order code 1SDA072184R1, is the three-pole moving part of a withdrawable SACE Emax 2 air circuit breaker, designed for dependable protection and switching in low-voltage AC distribution systems. Rated at 1250 A, it combines ABB's compact E1.2C breaker platform with the advanced Ekip Touch electronic protection system.

The Ekip Touch LI electronic trip unit provides long-time overload (L) and instantaneous short-circuit (I) protection. Its touchscreen interface gives operators convenient access to protection settings and electrical information, while the Ekip Touch platform supports the measurement, connectivity and digital capabilities associated with ABB's Emax 2 architecture.

As a WMP moving part, the 1SDA072184R1 is designed for installation in the corresponding ABB Emax 2 withdrawable fixed part or cradle. The E1.2C performance class provides a rated ultimate short-circuit breaking capacity of 50 kA at 400 V AC, making this breaker suitable for demanding industrial, commercial and infrastructure distribution systems.

Key Advantages

  • 1250 A three-pole Emax 2 moving part for withdrawable air circuit breaker installations.
  • Ekip Touch LI electronic trip unit provides adjustable overload and instantaneous short-circuit protection.
  • 500–1250 A overload release adjustment range supports application-specific protection settings.
  • 1875–18750 A instantaneous short-circuit adjustment range provides rapid protection against severe faults.
  • 50 kA rated ultimate short-circuit breaking capacity at 400 V AC.
  • 690 V AC rated voltage supports a broad range of low-voltage distribution applications.
  • Touchscreen-based Ekip interface simplifies protection configuration and system monitoring.
  • Withdrawable construction facilitates inspection, servicing and replacement.
  • Four change-over auxiliary contacts support switchboard signalling and control.

Key Features

  • ABB SACE Emax 2 E1.2C series.
  • 1250 A rated uninterrupted current (Iu).
  • Three-pole configuration.
  • Withdrawable moving-part construction.
  • Ekip Touch LI solid-state electronic release.
  • Long-time overload (L) protection.
  • Instantaneous short-circuit (I) protection.
  • 500–1250 A adjustable overload setting.
  • 1875–18750 A adjustable instantaneous short-circuit setting.
  • 690 V AC rated voltage.
  • 50 kA Icu at 400 V AC.
  • Four change-over auxiliary contacts.
  • Circuit-breaker open/closed position indication.
  • Optional motor operating mechanism.
  • Designed for use with the corresponding Emax 2 withdrawable fixed part.

Advanced LI Protection for Withdrawable Power Distribution

The ABB Emax 2 withdrawable architecture allows the active circuit-breaker assembly to be removed from its fixed chassis, supporting efficient inspection, servicing and replacement while the permanent switchboard connections remain installed. This arrangement makes the E1.2C platform particularly suitable for distribution systems where maintainability and continuity of service are important design considerations.

The Ekip Touch LI release protects the circuit against sustained overloads and severe instantaneous short-circuit faults. Combined with the E1.2C frame's 1250 A current rating, 690 V AC rated voltage and 50 kA ultimate breaking capacity at 400 V AC, the 1SDA072184R1 provides a capable protection solution for appropriately coordinated low-voltage power networks.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Commercial building electrical distribution.
  • Manufacturing and process plant switchboards.
  • Transformer secondary distribution systems.
  • Incoming and high-current feeder protection.
  • Data centres and critical electrical infrastructure.
  • Withdrawable switchgear requiring convenient breaker servicing.
  • Distribution circuits requiring adjustable electronic LI protection.

Technical Specifications

Series SACE Emax 2
ABB order code 1SDA072184R1
Product type Air circuit breaker moving part
Frame E1.2
Performance level C
Rated current 1250 A
Rated uninterrupted current (Iu) 1250 A
Number of poles 3
Version Withdrawable moving part (WMP)
Trip unit Ekip Touch LI
Release type Solid-state electronic
Protection functions Long-time overload (L) and instantaneous short-circuit (I)
Overload release current setting 500–1250 A
Instantaneous short-circuit adjustment range 1875–18750 A
Integrated ground-fault protection No
Rated voltage 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 50 kA
Auxiliary contacts 4 change-over contacts
Circuit-breaker position indication Open/closed
Complete device with protection unit Yes
Integrated motor drive No
Optional motor drive Yes
Integrated undervoltage release No
Power loss 244 W

Frequently Asked Questions

What is the ABB 1SDA072184R1?

The ABB 1SDA072184R1 is the 1250 A three-pole moving part of a SACE Emax 2 E1.2C withdrawable air circuit breaker, fitted with an Ekip Touch LI solid-state electronic trip unit.

What protection does the Ekip Touch LI trip unit provide?

The Ekip Touch LI trip unit provides long-time overload (L) and instantaneous short-circuit (I) protection. The overload release can be adjusted from 500–1250 A, while the instantaneous short-circuit setting covers 1875–18750 A.

What is the breaking capacity of the ABB E1.2C 1250?

The E1.2C 1250 has a rated ultimate short-circuit breaking capacity of 50 kA at 400 V AC.

Is the ABB 1SDA072184R1 fixed or withdrawable?

The 1SDA072184R1 is the moving part of a withdrawable air circuit breaker and is designed for installation with the corresponding ABB Emax 2 fixed part or cradle.

Does the ABB 1SDA072184R1 provide ground-fault protection?

No. The Ekip Touch LI release provides long-time overload and instantaneous short-circuit protection. Applications requiring integrated ground-fault protection should use an appropriate Ekip Touch LSIG configuration.

Advanced Protection with Emax 2 Flexibility

ABB SACE Emax 2 withdrawable air circuit breakers combine configurable electronic protection, robust short-circuit performance and service-friendly construction for dependable operation in modern low-voltage power distribution systems.