ABB 1SDA072183R1 E1.2C 1250 Ekip Dip LSIG three-pole moving part for a withdrawable SACE Emax 2 air circuit breaker, rated at 1250 A and 690 V AC with electronic LSIG protection and 50 kA ultimate short-circuit breaking capacity at 400–440 V AC.
£3,611.33
The ABB E1.2C 1250 Ekip Dip LSIG 3p WMP, order code 1SDA072183R1, is the three-pole moving part of a withdrawable SACE Emax 2 air circuit breaker, designed for protection and switching in demanding low-voltage AC distribution systems. Rated at 1250 A, it combines ABB's compact E1.2C breaker platform with an Ekip Dip solid-state electronic protection release.
The Ekip Dip LSIG trip unit provides long-time overload (L), short-time delayed short-circuit (S), instantaneous short-circuit (I) and integrated ground-fault (G) protection. Its adjustable protection thresholds allow the breaker to be coordinated with other protective devices, supporting selective and dependable operation throughout industrial and commercial distribution networks.
As a WMP moving part, the 1SDA072183R1 is intended for use with the corresponding ABB Emax 2 fixed chassis. The E1.2C performance level provides a rated ultimate short-circuit breaking capacity of 50 kA at 400–440 V AC and 42 kA at 500–690 V AC, together with a rated short-time withstand current of 42 kA for 1 s.
Withdrawable air circuit breakers allow the active breaker assembly to be disconnected and removed from its fixed chassis, simplifying inspection, servicing and replacement while the switchboard's permanent connections remain installed. The ABB SACE Emax 2 E1.2 platform combines this service-friendly arrangement with compact construction and robust short-circuit performance for modern low-voltage distribution systems.
The Ekip Dip LSIG release protects against sustained overloads, delayed short circuits, severe instantaneous faults and ground faults. Combined with the E1.2C frame's 50 kA ultimate breaking capacity at 400–440 V AC and 42 kA short-time withstand capability for 1 s, the 1SDA072183R1 provides comprehensive protection for appropriately coordinated industrial and commercial electrical networks.
| Series | SACE Emax 2 |
|---|---|
| ABB order code | 1SDA072183R1 |
| Product type | Air circuit breaker moving part |
| Frame / subtype | E1.2 |
| Short-circuit performance level | C |
| Rated current (In) | 1250 A |
| Rated uninterrupted current (Iu) | 1250 A |
| Current type | AC |
| Number of poles | 3 |
| Version | Withdrawable moving part (WMP) |
| Trip unit | Ekip Dip LSIG |
| Release type | Electronic / solid-state |
| Protection functions | Long-time (L), short-time (S), instantaneous (I) and ground-fault (G) |
| Integrated earth-fault protection | Yes |
| Overload release current setting | 500–1250 A |
| Short-time delayed short-circuit adjustment | 750–12500 A |
| Instantaneous short-circuit adjustment | 1875–18750 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC | 50 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC | 50 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 50 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 42 kA |
| Rated service short-circuit breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw), 1 s | 42 kA |
| Rated short-time withstand current (Icw), 3 s | 24 kA |
| Connecting capacity | 1000 mm² |
| Auxiliary contacts | 4 change-over contacts |
| Circuit-breaker position indication | Open/closed |
| Integrated motor drive | No |
| Optional motor drive | Yes |
| Power loss | 244 W |
| Electrical endurance at Ue ≤ 440 V | 8000 cycles |
| Electrical endurance at 500–690 V | 6500 cycles |
| Mechanical endurance | 20000 cycles |
| Suitable for IT networks | Yes, up to 690 V |
| Product height | 363.5 mm |
| Product depth | 271 mm |
| Net weight | 18 kg |
| Package EAN | 8015644760335 |
| Country of origin | Italy |
| Reference standard | IEC 60947-2 |
The ABB 1SDA072183R1 is the 1250 A three-pole moving part of a SACE Emax 2 E1.2C withdrawable air circuit breaker, equipped with an Ekip Dip LSIG solid-state electronic trip unit.
The Ekip Dip LSIG trip unit provides long-time overload (L), short-time delayed short-circuit (S), instantaneous short-circuit (I) and integrated ground-fault (G) protection.
The E1.2C 1250 provides a rated ultimate short-circuit breaking capacity of 50 kA at 400–440 V AC and 42 kA at 500–690 V AC.
The 1SDA072183R1 is the moving part of a withdrawable air circuit breaker and is intended for installation with the corresponding ABB Emax 2 fixed chassis.
Yes. The Ekip Dip LSIG release incorporates ground-fault (G) protection in addition to long-time, short-time and instantaneous overcurrent protection.
ABB SACE Emax 2 withdrawable air circuit breakers combine configurable electronic protection, high fault-interruption capability and service-friendly construction for dependable protection of modern low-voltage power distribution systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.