ABB 1SDA072180R1 E1.2B 1250 Ekip G Hi-Touch LSIG 3p WMP is a 1250 A three-pole withdrawable SACE Emax 2 air circuit breaker moving part with advanced generator-oriented LSIG electronic protection and 42 kA short-circuit breaking capacity.
£6,425.16
The ABB E1.2B 1250 Ekip G Hi-Touch LSIG 3p WMP, order code 1SDA072180R1, is a high-performance three-pole air circuit breaker moving part designed for advanced generator protection and demanding low-voltage electrical distribution systems. Part of the ABB SACE Emax 2 air circuit breaker series, it combines the compact E1.2B frame with the sophisticated Ekip G Hi-Touch LSIG electronic trip unit for comprehensive protection, measurement and monitoring.
Designed specifically for withdrawable generator and power-distribution applications, the E1.2B provides convenient inspection and maintenance within compatible ABB Emax 2 assemblies. The Ekip G Hi-Touch LSIG protection unit combines long-time, short-time, instantaneous and ground-fault protection with advanced generator-oriented functions, making it particularly suitable for generating sets, standby power systems and critical electrical networks.
With a rated uninterrupted current of 1250 A, a rated operational voltage of up to 690 V AC, a rated ultimate short-circuit breaking capacity of 42 kA at 440 V AC and a rated short-time withstand current of 42 kA for 1 s, the E1.2B 1250 delivers robust performance for demanding installations. Its three-pole withdrawable moving-part configuration also supports efficient servicing and integration into professional low-voltage switchboards.
Air circuit breakers used in generator installations must provide dependable fault interruption while accommodating the protection requirements of generating equipment and connected distribution networks. The ABB SACE Emax 2 E1.2B platform combines a 1250 A current rating with 42 kA short-circuit and short-time withstand performance, making it suitable for generator switchboards and demanding low-voltage power systems.
The Ekip G Hi-Touch LSIG electronic trip unit combines long-time, short-time, instantaneous and ground-fault protection with advanced functionality intended for generator applications. This comprehensive protection architecture supports effective system coordination and helps protect generators, conductors, switchgear and connected equipment while supporting continuity of supply in critical power installations.
| Series | SACE Emax 2 |
|---|---|
| Frame | E1.2B |
| ABB order code | 1SDA072180R1 |
| Product group | Emax2 Air Circuit Breaker |
| Product type | Air circuit breaker moving part |
| Configuration | Withdrawable moving part (WMP) |
| Number of poles | 3 |
| Rated uninterrupted current (Iu) | 1250 A |
| Rated operational voltage | up to 690 V AC |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 42 kA |
| Rated short-time withstand current (Icw) for 1 s | 42 kA |
| Trip unit | Ekip G Hi-Touch LSIG |
| Release type | Electronic protection release |
| Protection functions | Long-time (L), short-time (S), instantaneous (I) and ground-fault (G) |
| Integrated ground-fault protection | Yes |
| Generator protection | Yes |
| Auxiliary contacts | 4 |
| Trip signalling contact | 1 |
| Main circuit connection | Through separate fixed part |
| Fixed part | Ordered separately |
| DIN rail mounting | No |
| Standard | IEC 60947 |
| Weight | 18 kg |
The ABB 1SDA072180R1 is an Emax 2 air circuit breaker moving part designed for advanced generator protection and low-voltage power distribution, providing electronic protection against overloads, short circuits and ground faults.
The E1.2B 1250 has a rated uninterrupted current of 1250 A, making it suitable for high-current generator and low-voltage power distribution applications.
The E1.2B 1250 has a rated ultimate short-circuit breaking capacity of 42 kA at 440 V AC and 42 kA at 690 V AC, together with a rated short-time withstand current of 42 kA for 1 s.
The Ekip G Hi-Touch LSIG electronic trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection together with advanced functionality for generator protection applications.
The 1SDA072180R1 is a three-pole withdrawable moving part (WMP) for the ABB SACE Emax 2 system. The compatible fixed part is ordered separately for installation in the switchboard.
ABB SACE Emax 2 air circuit breakers with Ekip G Hi-Touch protection technology provide advanced generator and low-voltage distribution protection, combining comprehensive LSIG functionality, robust short-circuit performance and flexible withdrawable installation for industrial, commercial and critical power applications.