1SDA072173R1 ABB E1.2B 1250 Ekip Dip LSIG 3p WMP Air Circuit Breaker

1SDA072173R1 ABB E1.2B 1250 Ekip Dip LSIG 3p WMP Air Circuit Breaker

ABB 1SDA072173R1 Emax 2 E1.2B 1250 three-pole withdrawable air circuit breaker moving part with a 1250 A rated current, 42 kA short-circuit breaking capacity and Ekip Dip LSIG electronic protection.

SKU: 1SDA072173R1MPN: 1SDA072173R1
Price
List Price £4,654.60 ex VAT
Your Price (ex VAT) Save 25%
£3,490.95 25% OFF
You save £1,163.65 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,490.95
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,490.95

Why Choose the ABB E1.2B 1250 Ekip Dip LSIG 3p WMP Air Circuit Breaker?

The ABB E1.2B 1250 Ekip Dip LSIG 3p WMP, order code 1SDA072173R1, is a withdrawable Emax 2 air circuit breaker (ACB) moving part designed for dependable protection and switching in low-voltage electrical distribution systems. As part of the ABB SACE Emax 2 series, this three-pole unit combines a 1250 A rated current with an Ekip Dip LSIG electronic trip unit for comprehensive overload, short-circuit and ground-fault protection.

The compact E1.2B platform is designed for industrial and commercial switchboards where reliable fault interruption, selective protection and efficient use of panel space are important. Its Ekip Dip LSIG solid-state release provides long-time, short-time, instantaneous and ground-fault protection functions, enabling the breaker to respond to sustained overloads, short circuits and earth-fault conditions.

With a 1250 A rated current, a three-pole configuration and an ultimate short-circuit breaking capacity of 42 kA at 415 V AC and 690 V AC, the E1.2B 1250 is suited to demanding distribution applications. The WMP withdrawable moving-part configuration is designed for installation with the corresponding Emax 2 fixed part, which is ordered separately, supporting convenient isolation, testing and maintenance.

Key Advantages

  • Compact ABB Emax 2 air circuit breaker for low-voltage power distribution.
  • 1250 A rated current for demanding industrial and commercial distribution circuits.
  • 42 kA ultimate short-circuit breaking capacity at 415 V AC.
  • 42 kA ultimate short-circuit breaking capacity at 690 V AC.
  • Three-pole configuration for three-phase electrical systems.
  • Reliable Ekip Dip LSIG electronic trip unit.
  • Long-time, short-time, instantaneous and ground-fault protection.
  • Adjustable overload protection from 500–1250 A.
  • Short-time protection supports selective coordination between upstream and downstream protective devices.
  • Withdrawable construction supports convenient isolation, inspection and maintenance.

Key Features

  • ABB SACE Emax 2 E1.2B air circuit breaker moving part.
  • 1250 A rated current.
  • Three-pole (3P) configuration.
  • 42 kA Icu at 415 V AC.
  • 42 kA Icu at 690 V AC.
  • Ekip Dip LSIG solid-state electronic protection release.
  • Long-time protection against sustained overload conditions.
  • Short-time protection for delayed short-circuit interruption and selective coordination.
  • Instantaneous protection for rapid interruption of severe short circuits.
  • Integrated ground-fault protection for earth-fault conditions.
  • 500–1250 A adjustable overload protection range.
  • 1.5–15 × In adjustable instantaneous protection range.
  • Four auxiliary contacts for circuit-breaker status signalling.
  • Trip signalling contact supplied as standard.
  • Withdrawable moving part (WMP) for switchboard applications.
  • Designed for use with the corresponding Emax 2 fixed part.

Comprehensive LSIG Protection for Power Distribution

The ABB Emax 2 E1.2B provides switching, isolation and protection for important circuits within low-voltage electrical distribution systems. Its 1250 A current rating and 42 kA ultimate short-circuit breaking capacity provide dependable fault interruption for incoming supplies, distribution feeders and other critical circuits in industrial and commercial switchboards.

The Ekip Dip LSIG trip unit provides four fundamental electronic protection functions. Long-time protection responds to sustained overloads, short-time protection enables delayed fault clearing and improved selectivity, instantaneous protection rapidly interrupts severe short circuits, and ground-fault protection responds to earth-fault conditions. Combined with the withdrawable Emax 2 construction, these functions provide a practical solution for maintainable and coordinated low-voltage power distribution.

Typical Applications

  • Low-voltage distribution switchboards.
  • Industrial power distribution systems.
  • Commercial building electrical distribution.
  • Incoming and outgoing feeder protection.
  • Selective and coordinated distribution networks.
  • Manufacturing and production facilities.
  • Infrastructure and process installations.
  • Systems requiring integrated ground-fault protection.
  • High-current distribution circuits up to 1250 A.
  • Withdrawable switchgear requiring convenient isolation and maintenance.

Technical Specifications

Product group Emax2 Air Circuit Breaker
Series SACE Emax 2
ABB order code 1SDA072173R1
EAN 8015644760236
Product type Air circuit breaker moving part
Frame E1.2
Performance level B
Rated current 1250 A
Number of poles 3
Current type AC
Ultimate short-circuit breaking capacity (Icu) 42 kA at 415 V AC
Trip unit Ekip Dip LSIG
Release type Electronic / solid-state
Protection functions Long-time, short-time, instantaneous and ground fault (LSIG)
Overload protection adjustment 500–1250 A
Short-time protection Adjustable
Instantaneous protection adjustment 1.5–15 × In
Ground-fault protection Integrated and adjustable
Execution Withdrawable moving part (WMP)
Auxiliary contacts 4
Trip signalling contact 1
Fixed part Ordered separately
Application Low-voltage power distribution and circuit protection

Frequently Asked Questions

What is the ABB 1SDA072173R1 used for?

The ABB 1SDA072173R1 is an Emax 2 air circuit breaker moving part designed for switching and protecting three-phase low-voltage electrical distribution circuits in industrial and commercial switchboards.

What is the rated current of the ABB E1.2B 1250?

The circuit breaker has a rated current of 1250 A, with an adjustable long-time overload protection range of 500–1250 A.

What protection unit does the 1SDA072173R1 use?

The breaker uses an Ekip Dip LSIG electronic trip unit providing long-time, short-time, instantaneous and ground-fault protection.

What is the breaking capacity of the ABB E1.2B 1250?

The E1.2B 1250 has an ultimate short-circuit breaking capacity of 42 kA at 415 V AC and 42 kA at 690 V AC.

What does WMP mean on the ABB E1.2B 1250?

WMP identifies the withdrawable moving part of the circuit breaker. It is designed for installation with the corresponding ABB Emax 2 fixed part, which is ordered separately, allowing the breaker to be withdrawn for isolation, testing and maintenance.

Trusted Circuit Protection from ABB

ABB SACE Emax 2 air circuit breakers combine dependable low-voltage circuit protection with electronic trip technology, selective coordination, ground-fault protection and flexible withdrawable switchgear integration for modern industrial and commercial power distribution systems.