ABB 1SDA071970R1 E6.2V/f 4000 Ekip G Hi-Touch LSIG four-pole fixed full-size-neutral air circuit breaker for generator and power-distribution protection with a 4000 A rated uninterrupted current, integrated earth-fault protection and up to 150 kA ultimate short-circuit breaking capacity.
£29,146.76
The ABB E6.2V/f 4000 Ekip G Hi-Touch LSIG 4p FHR, order code 1SDA071970R1, is a high-performance four-pole SACE Emax 2 air circuit breaker engineered for generator protection and demanding low-voltage power-distribution systems. This E6.2V/f full-size-neutral version combines a 4000 A rated uninterrupted current with ABB's advanced Ekip G Hi-Touch LSIG electronic trip unit.
The E6.2V/f performance level delivers exceptional short-circuit capability, with a rated ultimate short-circuit breaking capacity of 150 kA at 415 V AC and 100 kA at 690 V AC, together with a rated short-time withstand current of 100 kA. Its Ekip G Hi-Touch LSIG release combines long-time overload, selective short-time, instantaneous short-circuit and earth-fault protection with generator-oriented functions and advanced electrical monitoring.
This model is a fixed four-pole air circuit breaker with a full-size neutral and rear horizontal (FHR) terminals. Supplied with four auxiliary contacts and a trip signalling contact, the 1SDA071970R1 provides a robust protection platform for generator switchboards, critical power systems, industrial plants, data centres and high-capacity distribution networks requiring advanced protection and monitoring.
Generator-fed and multi-source electrical networks require protection capable of responding to operating conditions that differ from conventional utility-fed systems. The ABB E6.2V/f combines a 4000 A rated uninterrupted current, full-size neutral construction, up to 150 kA ultimate short-circuit breaking capacity and 100 kA short-time withstand capability, providing a robust platform for major generator incomers, busbars and high-capacity distribution feeders.
The Ekip G Hi-Touch LSIG trip unit combines generator-oriented protection with advanced measurement, monitoring and power-quality functionality. Long-time, selective short-time, instantaneous and earth-fault protection functions help safeguard critical equipment against a broad range of abnormal conditions, while Network Analyzer functionality supports detailed supervision of power quality within sophisticated low-voltage electrical networks.
| Series | SACE Emax 2 E6.2 |
|---|---|
| Order code / MPN | 1SDA071970R1 |
| EAN / GTIN | 8015644758202 |
| Product type | Air circuit breaker (ACB) |
| Product group | Emax 2 Air Circuit Breaker |
| Frame / performance level | E6.2V/f |
| Rated uninterrupted current (Iu) | 4000 A |
| Rated voltage range | 220–690 V |
| Number of poles | 4 |
| Neutral configuration | Full-size neutral |
| Trip unit | Ekip G Hi-Touch LSIG |
| Release technology | Electronic |
| Protection functions | Long-time, short-time, instantaneous and earth-fault (LSIG) |
| Generator-oriented protection | Yes |
| Integrated earth-fault protection | Yes |
| Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC | 150 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 100 kA |
| Rated short-time withstand current (Icw) | 100 kA |
| Execution | Fixed |
| Main terminals | Rear horizontal (FHR) |
| Main-circuit connection | Bolted |
| Auxiliary contacts | 4 |
| Trip signalling contact | 1 |
| Network Analyzer | Integrated |
| Product net weight | 161 kg |
| Country of origin | Italy |
The ABB 1SDA071970R1 is an Emax 2 air circuit breaker configured with an Ekip G Hi-Touch LSIG trip unit for protection and switching of high-current generator and low-voltage power-distribution systems.
E6.2 identifies the Emax 2 frame, V identifies its high short-circuit performance level, and the /f designation identifies the four-pole full-size-neutral configuration.
The Ekip G Hi-Touch LSIG electronic trip unit provides long-time overload, selective short-time, instantaneous short-circuit and integrated earth-fault protection together with generator-oriented protection and advanced monitoring functionality.
The E6.2V/f 4000 provides a rated ultimate short-circuit breaking capacity of 150 kA at 415 V AC and 100 kA at 690 V AC, with a rated short-time withstand current of 100 kA.
The 1SDA071970R1 is a fixed four-pole, full-size-neutral air circuit breaker supplied with rear horizontal terminals, four auxiliary contacts and a trip signalling contact.
ABB SACE Emax 2 air circuit breakers with Ekip G Hi-Touch protection combine high current-carrying capability, generator-oriented electronic protection, advanced monitoring and exceptional fault-interruption performance for demanding critical-power and low-voltage distribution systems.