1SDA071951R1 ABB E6.2H/f 4000 Ekip Dip LI 4p FHR Air Circuit Breaker

1SDA071951R1 ABB E6.2H/f 4000 Ekip Dip LI 4p FHR Air Circuit Breaker

ABB 1SDA071951R1 Emax 2 E6.2H/f 4000 Ekip Dip LI four-pole fixed air circuit breaker rated at 4000 A with 100 kA breaking capacity at 440 V AC, 100 kA one-second withstand capability and long-time overload plus instantaneous short-circuit protection.

SKU: 1SDA071951R1MPN: 1SDA071951R1
Price
List Price £31,652.40 ex VAT
Your Price (ex VAT) Save 25%
£23,739.30 25% OFF
You save £7,913.10 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £23,739.30
Trade pricing is personalised to your account

Manufacturer Lead Time

£23,739.30

Why Choose the ABB E6.2H/f 4000 Ekip Dip LI 4p FHR Air Circuit Breaker?

The ABB 1SDA071951R1 is a high-performance Emax 2 air circuit breaker (ACB) designed for protection, switching and isolation in demanding low-voltage power-distribution systems. Identified as the E6.2H/f 4000 Ekip Dip LI 4p FHR, this four-pole fixed circuit breaker combines a 4000 A rated uninterrupted current with ABB’s Ekip Dip LI electronic trip unit.

As part of the ABB SACE Emax 2 E6.2H/f full-size series, this breaker provides high short-circuit performance for industrial, commercial and infrastructure installations. The Ekip Dip LI release provides long-time overload and instantaneous short-circuit protection, offering straightforward electronic protection for high-current distribution networks.

With an ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 100 kA for 1 s, the 1SDA071951R1 is engineered for installations with substantial prospective fault currents. Its fully rated fourth pole, fixed construction and rear horizontal terminals provide a robust configuration for permanent integration into high-capacity low-voltage switchboards.

Key Advantages

  • High-performance ABB Emax 2 E6.2H/f full-size air circuit breaker.
  • 4000 A rated uninterrupted current for high-current power-distribution systems.
  • 100 kA Icu at 440 V AC for dependable interruption of high prospective fault currents.
  • 100 kA Icw for 1 s supports demanding selective protection strategies.
  • Ekip Dip LI electronic trip unit provides long-time overload and instantaneous short-circuit protection.
  • Fully rated fourth pole for four-pole switching and protection applications.
  • Fixed construction with rear horizontal terminals for permanent switchboard installation.
  • ABB Emax 2 architecture provides a robust platform for critical low-voltage distribution systems.

Key Features

  • ABB SACE Emax 2 E6.2H/f full-size series.
  • 4000 A rated uninterrupted current.
  • 100 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 100 kA rated short-time withstand current for 1 s.
  • Ekip Dip LI electronic protection release.
  • Long-time overload protection.
  • Instantaneous short-circuit protection.
  • DIP-switch based protection configuration.
  • 4-pole configuration with fully rated fourth pole.
  • Fixed circuit-breaker construction.
  • Rear horizontal main terminals.
  • Designed for high-current low-voltage power distribution.
  • Protection and switching solution for critical electrical infrastructure.
  • Compliant with the Emax 2 platform’s IEC power-distribution architecture.

High-Current Power Distribution Protection

The ABB Emax 2 E6.2H/f platform is designed for high-current low-voltage systems where substantial fault-interruption capability and dependable circuit protection are required. With a 4000 A rated uninterrupted current, 100 kA ultimate breaking capacity at 440 V AC and 100 kA one-second short-time withstand capability, this breaker is well suited to critical distribution points exposed to high prospective fault currents.

The Ekip Dip LI electronic trip unit provides long-time overload and instantaneous short-circuit protection. This LI configuration is particularly appropriate where straightforward overload and rapid high-level short-circuit protection are required without dedicated short-time selective or integrated earth-fault functions.

Typical Applications

  • Main incomer protection in high-current low-voltage switchboards.
  • Industrial power-distribution systems.
  • Transformer secondary distribution.
  • Manufacturing and process plants.
  • Large commercial electrical installations.
  • Data centres and critical power systems.
  • Utility and infrastructure electrical distribution.
  • High-current switchboards requiring a fully rated fourth pole.

Technical Specifications

Product group Emax 2 Air Circuit Breaker
Range SACE Emax 2
Series E6.2H/f
Frame style Full size
ABB order code / MPN 1SDA071951R1
Product type Air circuit breaker
Rated uninterrupted current (Iu) 4000 A
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated short-time withstand current (Icw) 100 kA for 1 s
Number of poles 4
Fourth pole Fully rated
Short-circuit performance level H
Trip unit Ekip Dip LI
Release type Electronic
Protection functions LI
Long-time overload protection Yes
Instantaneous short-circuit protection Yes
Short-time selective protection No dedicated S protection function
Integrated earth-fault protection No
Installation Fixed
Terminal position Rear
Terminal configuration Rear horizontal
ABB terminal designation HR
Application Low-voltage power distribution
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071951R1 used for?

The ABB 1SDA071951R1 is an Emax 2 air circuit breaker designed for high-current low-voltage switching, isolation and circuit protection in industrial, commercial and infrastructure power-distribution systems.

What is the current rating of the ABB 1SDA071951R1?

The E6.2H/f 4000 has a rated uninterrupted current of 4000 A, making it suitable for major high-current electrical distribution systems.

What is the breaking capacity of the E6.2H/f 4000?

The breaker has an ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 100 kA for 1 s.

What protection functions does the Ekip Dip LI provide?

The Ekip Dip LI electronic trip unit provides long-time overload and instantaneous short-circuit protection. This LI configuration does not include dedicated short-time selective or integrated earth-fault protection functions.

How is the ABB 1SDA071951R1 installed?

This model is a four-pole fixed air circuit breaker with a fully rated fourth pole and rear horizontal terminals for permanent integration into compatible high-current low-voltage switchboards.

Trusted High-Performance Power Protection

ABB SACE Emax 2 air circuit breakers combine high current-handling and fault-interruption capability with configurable electronic protection, helping demanding industrial and infrastructure installations achieve dependable overload and short-circuit protection while supporting safe and reliable power distribution.