ABB 1SDA071951R1 Emax 2 E6.2H/f 4000 Ekip Dip LI four-pole fixed air circuit breaker rated at 4000 A with 100 kA breaking capacity at 440 V AC, 100 kA one-second withstand capability and long-time overload plus instantaneous short-circuit protection.
£23,739.30
The ABB 1SDA071951R1 is a high-performance Emax 2 air circuit breaker (ACB) designed for protection, switching and isolation in demanding low-voltage power-distribution systems. Identified as the E6.2H/f 4000 Ekip Dip LI 4p FHR, this four-pole fixed circuit breaker combines a 4000 A rated uninterrupted current with ABB’s Ekip Dip LI electronic trip unit.
As part of the ABB SACE Emax 2 E6.2H/f full-size series, this breaker provides high short-circuit performance for industrial, commercial and infrastructure installations. The Ekip Dip LI release provides long-time overload and instantaneous short-circuit protection, offering straightforward electronic protection for high-current distribution networks.
With an ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 100 kA for 1 s, the 1SDA071951R1 is engineered for installations with substantial prospective fault currents. Its fully rated fourth pole, fixed construction and rear horizontal terminals provide a robust configuration for permanent integration into high-capacity low-voltage switchboards.
The ABB Emax 2 E6.2H/f platform is designed for high-current low-voltage systems where substantial fault-interruption capability and dependable circuit protection are required. With a 4000 A rated uninterrupted current, 100 kA ultimate breaking capacity at 440 V AC and 100 kA one-second short-time withstand capability, this breaker is well suited to critical distribution points exposed to high prospective fault currents.
The Ekip Dip LI electronic trip unit provides long-time overload and instantaneous short-circuit protection. This LI configuration is particularly appropriate where straightforward overload and rapid high-level short-circuit protection are required without dedicated short-time selective or integrated earth-fault functions.
| Product group | Emax 2 Air Circuit Breaker |
|---|---|
| Range | SACE Emax 2 |
| Series | E6.2H/f |
| Frame style | Full size |
| ABB order code / MPN | 1SDA071951R1 |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 4000 A |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 100 kA |
| Rated short-time withstand current (Icw) | 100 kA for 1 s |
| Number of poles | 4 |
| Fourth pole | Fully rated |
| Short-circuit performance level | H |
| Trip unit | Ekip Dip LI |
| Release type | Electronic |
| Protection functions | LI |
| Long-time overload protection | Yes |
| Instantaneous short-circuit protection | Yes |
| Short-time selective protection | No dedicated S protection function |
| Integrated earth-fault protection | No |
| Installation | Fixed |
| Terminal position | Rear |
| Terminal configuration | Rear horizontal |
| ABB terminal designation | HR |
| Application | Low-voltage power distribution |
| Standard | IEC 60947-2 |
The ABB 1SDA071951R1 is an Emax 2 air circuit breaker designed for high-current low-voltage switching, isolation and circuit protection in industrial, commercial and infrastructure power-distribution systems.
The E6.2H/f 4000 has a rated uninterrupted current of 4000 A, making it suitable for major high-current electrical distribution systems.
The breaker has an ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 100 kA for 1 s.
The Ekip Dip LI electronic trip unit provides long-time overload and instantaneous short-circuit protection. This LI configuration does not include dedicated short-time selective or integrated earth-fault protection functions.
This model is a four-pole fixed air circuit breaker with a fully rated fourth pole and rear horizontal terminals for permanent integration into compatible high-current low-voltage switchboards.
ABB SACE Emax 2 air circuit breakers combine high current-handling and fault-interruption capability with configurable electronic protection, helping demanding industrial and infrastructure installations achieve dependable overload and short-circuit protection while supporting safe and reliable power distribution.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.