ABB 1SDA071940R1 Emax 2 E6.2V 6300 Ekip G Hi-Touch LSIG four-pole fixed air circuit breaker rated at 6300 A and 690 V AC with 150 kA breaking capacity at 400 V AC and advanced generator, overload, short-circuit and earth-fault protection.
£50,692.54
The ABB 1SDA071940R1 is a high-capacity Emax 2 air circuit breaker (ACB) engineered for demanding generator and low-voltage power-distribution applications. Identified as the E6.2V 6300 Ekip G Hi-Touch LSIG 4p FHR, this four-pole fixed circuit breaker combines a substantial 6300 A rated uninterrupted current with ABB’s advanced Ekip G Hi-Touch LSIG electronic protection release.
As part of the ABB SACE Emax 2 E6.2V series, this breaker delivers exceptionally high short-circuit performance for critical industrial, generator and infrastructure installations. The Ekip G Hi-Touch LSIG release provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection while adding advanced measurement, monitoring and power-management functionality.
With a rated voltage of 690 V AC, an ultimate short-circuit breaking capacity of 150 kA at 400 V AC and a rated short-time withstand current of 100 kA for 1 s, the 1SDA071940R1 is engineered for electrical systems with exceptionally high prospective fault currents. Its four-pole fixed construction and rear flat horizontal terminals provide a robust configuration for permanent integration into high-capacity low-voltage switchboards.
The ABB Emax 2 E6.2V platform is engineered for high-current low-voltage systems where exceptional short-circuit performance, selective protection and sophisticated power management are required. With a 6300 A current rating, 150 kA breaking capacity at 400 V AC and a 100 kA one-second short-time withstand rating, the E6.2V 6300 is particularly suited to critical distribution positions exposed to very high prospective fault currents.
The Ekip G Hi-Touch LSIG electronic trip unit combines generator-oriented protection with advanced measurement and monitoring capabilities. Its long-time, short-time, instantaneous and earth-fault functions help protect generators, transformers, busbars, cables and connected equipment while supporting selective coordination, continuity of service, automation and sophisticated energy-management strategies.
| Product group | Emax 2 Air Circuit Breaker |
|---|---|
| Range | SACE Emax 2 |
| Series | E6.2V |
| ABB order code / MPN | 1SDA071940R1 |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 6300 A |
| Rated voltage | 690 V AC |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC | 150 kA |
| Rated short-time withstand current (Icw) | 100 kA for 1 s |
| Number of poles | 4 |
| Short-circuit performance level | V |
| Trip unit | Ekip G Hi-Touch LSIG |
| Release type | Electronic |
| Protection functions | LSIG |
| Overload release adjustment range | 2520–6300 A |
| Short-time delayed short-circuit adjustment range | 3780–63000 A |
| Instantaneous short-circuit adjustment range | 9450–94500 A |
| Integrated earth-fault protection | Yes |
| Complete device with protection unit | Yes |
| Installation | Fixed |
| Terminal position | Rear |
| Terminal type | Rear flat horizontal |
| Auxiliary contacts | 4 change-over contacts |
| Switched-off indication | Yes |
| Motor drive integrated | No |
| Motor drive optional | Yes |
| Width | 888 mm |
| Depth | 270 mm |
| Net weight | 125 kg |
| Standards / approvals | IEC |
| Country of origin | Italy |
The ABB 1SDA071940R1 is an Emax 2 air circuit breaker designed for high-current generator and low-voltage power-distribution applications requiring advanced electronic protection, measurement and monitoring.
The E6.2V 6300 has a rated uninterrupted current of 6300 A, making it suitable for major generator, industrial, utility and infrastructure electrical systems.
The E6.2V performance level provides an ultimate short-circuit breaking capacity of 150 kA at 400 V AC, together with a rated short-time withstand current of 100 kA for 1 s.
The Ekip G Hi-Touch LSIG electronic trip unit provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and integrated earth-fault protection together with advanced measurement and monitoring capabilities for generator and power-distribution applications.
This model is a four-pole fixed air circuit breaker equipped with rear flat horizontal terminals for permanent integration into compatible high-current low-voltage switchboards and power-distribution assemblies.
ABB SACE Emax 2 air circuit breakers combine very high current-handling and fault-interruption capability with advanced electronic protection, measurement and power-management functionality, helping generator, industrial and infrastructure installations achieve dependable protection while supporting selectivity, automation and continuity of service.