1SDA071910R1 ABB E6.2V 5000 Ekip G Hi-Touch LSIG 4p FHR Air Circuit Breaker

1SDA071910R1 ABB E6.2V 5000 Ekip G Hi-Touch LSIG 4p FHR Air Circuit Breaker

ABB 1SDA071910R1 is a SACE Emax 2 E6.2V 5000 A four-pole fixed air circuit breaker with Ekip G Hi-Touch LSIG electronic protection and 150 kA ultimate breaking capacity at 440 V AC.

SKU: 1SDA071910R1MPN: 1SDA071910R1
Price
List Price £51,881.39 ex VAT
Your Price (ex VAT) Save 25%
£38,911.04 25% OFF
You save £12,970.35 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £38,911.04
Trade pricing is personalised to your account

Manufacturer Lead Time

£38,911.04

Why Choose the ABB E6.2V 5000 Ekip G Hi-Touch LSIG 4p FHR Air Circuit Breaker?

The ABB E6.2V 5000 Ekip G Hi-Touch LSIG 4p FHR, order code 1SDA071910R1, is a high-performance SACE Emax 2 air circuit breaker designed for advanced protection and control of demanding low-voltage power distribution and generator systems. With a 5000 A rated current, four-pole construction and sophisticated Ekip G Hi-Touch LSIG electronic trip unit, it provides comprehensive protection, measurement and monitoring for high-current electrical installations.

As part of the ABB SACE Emax 2 E6.2V range, this circuit breaker combines very high short-circuit performance with generator-oriented electronic protection. The Ekip G Hi-Touch LSIG release provides long-time, short-time, instantaneous and ground-fault protection functions together with advanced monitoring capabilities, making the breaker particularly suitable for sophisticated power generation and distribution systems.

The E6.2V performance level provides an ultimate short-circuit breaking capacity of 150 kA at 440 V AC and a rated short-time withstand current of 100 kA for 1 second. This fixed four-pole configuration uses rear horizontal terminals and is supplied with four auxiliary contacts and circuit-breaker open/closed position indication for integration into high-power switchboards.

Key Advantages

  • High-performance ABB SACE Emax 2 E6.2V air circuit breaker.
  • 5000 A rated uninterrupted current for high-power electrical systems.
  • Four-pole configuration for switching three phases and neutral.
  • Advanced Ekip G Hi-Touch LSIG electronic trip unit for generator and distribution protection.
  • 150 kA ultimate breaking capacity at 440 V AC for installations with very high prospective fault currents.
  • 100 kA short-time withstand current for 1 second.
  • Fixed execution with rear horizontal terminals for switchboard integration.

Key Features

  • ABB SACE Emax 2 E6.2V series.
  • 5000 A rated uninterrupted current.
  • Four-pole construction.
  • Ekip G Hi-Touch LSIG solid-state electronic protection release.
  • Long-time, short-time, instantaneous and ground-fault protection functions.
  • 150 kA Icu at 440 V AC.
  • 100 kA Icw for 1 second.
  • Fixed circuit-breaker execution.
  • Rear horizontal main-circuit terminals.
  • Four auxiliary contacts with circuit-breaker open/closed position indication.

Advanced Generator and Power Distribution Protection

ABB SACE Emax 2 air circuit breakers combine high-current switching and short-circuit interruption with intelligent electronic protection and power-management capabilities. The Ekip G Hi-Touch release is specifically suited to advanced generator applications, providing extensive protection and supervision functions for generating sets and low-voltage distribution networks.

The LSIG protection functions provide protection against overloads, delayed and instantaneous short circuits and ground faults. Combined with the E6.2V breaker's high short-circuit performance, the 1SDA071910R1 is suited to critical installations where selectivity, continuity of service and comprehensive electrical system protection are essential.

Typical Applications

  • Generator protection and generator switchboards.
  • High-current low-voltage distribution systems.
  • Main incoming and distribution switchboards.
  • Industrial plants and manufacturing facilities.
  • Power generation and infrastructure installations.
  • Data centres and critical power systems.

Technical Specifications

Series SACE Emax 2 E6.2V
Order code 1SDA071910R1
Product type Air circuit breaker
Rated uninterrupted current (Iu) 5000 A
Number of poles 4
Trip unit Ekip G Hi-Touch LSIG
Protection functions LSIG – long-time, short-time, instantaneous and ground-fault
Rated operational voltage 690 V AC
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 150 kA
Rated short-time withstand current (Icw), 1 s 100 kA
Overload release adjustment range 2000–5000 A
Short-time delayed short-circuit adjustment range 3000–50000 A
Installation Fixed
Main terminal arrangement Rear horizontal
Auxiliary contacts 4
EAN 8015644757601
Standards IEC

Frequently Asked Questions

What is the ABB 1SDA071910R1 used for?

It is an ABB SACE Emax 2 air circuit breaker designed for high-current low-voltage distribution and advanced generator protection applications.

What is the rated current of the ABB E6.2V 1SDA071910R1?

The circuit breaker has a rated uninterrupted current of 5000 A.

What protection does the Ekip G Hi-Touch LSIG trip unit provide?

The Ekip G Hi-Touch LSIG release provides long-time, short-time, instantaneous and ground-fault protection, together with advanced generator protection, measurement and monitoring capabilities.

What is the breaking capacity of this E6.2V circuit breaker?

The E6.2V has an ultimate short-circuit breaking capacity of 150 kA at 440 V AC and a rated short-time withstand current of 100 kA for 1 second.

How is the ABB 1SDA071910R1 installed?

This model is a fixed four-pole circuit breaker with rear horizontal terminals, designed for integration into high-current low-voltage switchboards.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers combine high breaking performance, advanced electronic protection and intelligent power-management capabilities for demanding power generation, industrial, commercial and infrastructure electrical systems.