1SDA071909R1 ABB E6.2V 5000 Ekip Hi-Touch LSIG 4p FHR Air Circuit Breaker

1SDA071909R1 ABB E6.2V 5000 Ekip Hi-Touch LSIG 4p FHR Air Circuit Breaker

ABB 1SDA071909R1 Emax 2 E6.2V 5000 is a 5000 A four-pole fixed air circuit breaker with Ekip Hi-Touch LSIG electronic protection, 150 kA breaking capacity at 440 V AC and rear horizontal terminals for demanding high-current low-voltage power distribution systems.

SKU: 1SDA071909R1MPN: 1SDA071909R1
Price
List Price £51,277.26 ex VAT
Your Price (ex VAT) Save 25%
£38,457.95 25% OFF
You save £12,819.32 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £38,457.95
Trade pricing is personalised to your account

Manufacturer Lead Time

£38,457.95

Why Choose the ABB E6.2V 5000 Ekip Hi-Touch LSIG 4p FHR Air Circuit Breaker?

The ABB E6.2V 5000 Ekip Hi-Touch LSIG 4p FHR, order code 1SDA071909R1, is a high-performance four-pole air circuit breaker (ACB) designed for protection, switching and isolation in demanding low-voltage power distribution systems. Part of the ABB SACE Emax 2 series, it combines a substantial 5000 A rated current with exceptional short-circuit performance for major industrial, commercial and infrastructure installations.

This Emax 2 circuit breaker incorporates the Ekip Hi-Touch LSIG electronic trip unit, providing long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection. Its comprehensive electronic protection functions support accurate coordination between protective devices while providing dedicated protection against earth faults in complex electrical distribution networks.

The E6.2V 5000 is a fixed, four-pole breaker with rear horizontal terminals. The E6.2V performance level provides an ultimate short-circuit breaking capacity of 150 kA at 440 V AC and a rated short-time withstand current of 100 kA for 1 s, making it particularly suitable for high-fault-level incoming supplies, transformer circuits and critical main distribution switchboards.

Key Advantages

  • High-capacity 5000 A air circuit breaker for demanding low-voltage power distribution systems.
  • Four-pole configuration for comprehensive switching, protection and isolation.
  • Advanced Ekip Hi-Touch LSIG electronic trip unit for sophisticated circuit protection.
  • Long-time, short-time, instantaneous and earth-fault protection integrated into a single trip unit.
  • Exceptional 150 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 100 kA short-time withstand current for 1 s supports demanding selective distribution designs.
  • Fixed installation for permanent integration into low-voltage switchboards.
  • Rear horizontal terminals facilitate integration with high-current busbar systems.

Key Features

  • ABB SACE Emax 2 E6.2V air circuit breaker.
  • 5000 A rated uninterrupted current.
  • Four-pole configuration.
  • Ekip Hi-Touch LSIG electronic trip unit.
  • Long-time overload (L) protection.
  • Short-time selective short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • Integrated earth-fault (G) protection.
  • Designed for low-voltage systems up to 690 V AC.
  • 150 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 100 kA rated short-time withstand current for 1 s.
  • Fixed construction with rear horizontal terminals.
  • High-performance E6.2 frame designed for demanding power distribution installations.

Advanced LSIG Protection for High-Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 E6.2V provide protection, switching and isolation for high-current low-voltage electrical networks. By detecting overloads, short circuits and earth faults, the breaker can disconnect the affected circuit to help protect cables, switchgear and connected equipment while supporting dependable operation of the wider distribution system.

The Ekip Hi-Touch LSIG trip unit combines long-time, short-time, instantaneous and earth-fault electronic protection with the advanced functionality of the Emax 2 platform. Combined with the E6.2V frame's 5000 A current rating, breaking capacity of up to 150 kA and high short-time withstand capability, the 1SDA071909R1 is particularly suited to critical high-power distribution applications where fault levels, selectivity and comprehensive protection requirements are substantial.

Typical Applications

  • Industrial low-voltage main distribution switchboards.
  • Manufacturing plants and large production facilities.
  • Transformer protection and distribution systems.
  • Generator and critical power distribution systems.
  • Data centres and high-availability infrastructure.
  • Utilities and major infrastructure installations.
  • High-fault-level incoming supply protection.
  • Main and feeder circuits requiring comprehensive LSIG protection.

Technical Specifications

Series SACE Emax 2
Order code / Product ID 1SDA071909R1
EAN 8015644757595
Product type Air circuit breaker
ABB product group Emax2 Air Circuit Breaker
Frame / subtype E6.2V
Performance level V
Rated current 5000 A
Rated uninterrupted current (Iu) 5000 A
Number of poles 4
Current type AC
Rated operational voltage up to 690 V AC
Ultimate short-circuit breaking capacity (Icu) 150 kA at 440 V AC
Rated short-time withstand current (Icw) 100 kA for 1 s
Trip unit Ekip Hi-Touch LSIG
Release type Electronic
Protection functions Long-time (L), short-time (S), instantaneous (I) and earth-fault (G)
Integrated earth-fault protection Yes
Installation version Fixed
Terminal configuration Rear horizontal
Main circuit connection Bolted
Degree of protection IP30
Product width 888 mm
Product height 371 mm
Product weight approximately 133 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071909R1 used for?

The ABB 1SDA071909R1 is a 5000 A four-pole air circuit breaker used for protection, switching and isolation in high-current, high-fault-level low-voltage power distribution systems.

What protection functions does the Ekip Hi-Touch LSIG trip unit provide?

The Ekip Hi-Touch LSIG electronic trip unit provides long-time overload (L), short-time selective short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection.

What is the breaking capacity of the ABB E6.2V 5000?

The E6.2V performance level provides an ultimate short-circuit breaking capacity of 150 kA at 440 V AC, making it suitable for demanding high-fault-current low-voltage distribution systems.

Is the 1SDA071909R1 a fixed or withdrawable circuit breaker?

The 1SDA071909R1 is a fixed-version circuit breaker equipped with rear horizontal terminals for permanent integration into low-voltage switchboards.

What does LSIG protection mean on the ABB E6.2V 5000?

LSIG denotes long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, providing comprehensive electronic protection for demanding low-voltage electrical distribution systems.

Trusted for High-Performance Power Distribution

ABB SACE Emax 2 air circuit breakers are designed for demanding low-voltage distribution systems where high current capacity, advanced electronic protection, effective selectivity and exceptional short-circuit performance are required.