1SDA071908R1 ABB E6.2V 5000 Ekip Hi-Touch LSI 4p FHR Air Circuit Breaker

1SDA071908R1 ABB E6.2V 5000 Ekip Hi-Touch LSI 4p FHR Air Circuit Breaker

ABB 1SDA071908R1 Emax 2 E6.2V 5000 is a 5000 A four-pole fixed air circuit breaker with Ekip Hi-Touch LSI electronic protection, up to 150 kA short-circuit breaking capacity and rear horizontal terminals for demanding high-current low-voltage power distribution systems.

SKU: 1SDA071908R1MPN: 1SDA071908R1
Price
List Price £50,653.57 ex VAT
Your Price (ex VAT) Save 25%
£37,990.18 25% OFF
You save £12,663.39 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £37,990.18
Trade pricing is personalised to your account

Manufacturer Lead Time

£37,990.18

Why Choose the ABB E6.2V 5000 Ekip Hi-Touch LSI 4p FHR Air Circuit Breaker?

The ABB E6.2V 5000 Ekip Hi-Touch LSI 4p FHR, order code 1SDA071908R1, is a high-performance four-pole air circuit breaker (ACB) designed for protection, switching and isolation in demanding low-voltage power distribution systems. Part of the ABB SACE Emax 2 series, it combines a substantial 5000 A rated current with exceptional short-circuit performance for major industrial, commercial and infrastructure installations.

This Emax 2 circuit breaker incorporates the Ekip Hi-Touch LSI electronic trip unit, providing long-time overload, short-time selective short-circuit and instantaneous short-circuit protection. Its advanced electronic protection capabilities support accurate coordination between protective devices, helping isolate electrical faults while maintaining continuity elsewhere in complex power distribution networks.

The E6.2V 5000 is a fixed, four-pole breaker with rear flat horizontal terminals. Rated for operation at up to 690 V AC, it provides an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC, 130 kA at 500–525 V AC and 100 kA at 690 V AC, together with a short-time withstand current of 100 kA for both 1 s and 3 s.

Key Advantages

  • High-capacity 5000 A air circuit breaker for demanding low-voltage power distribution systems.
  • Four-pole configuration for comprehensive switching and isolation.
  • Advanced Ekip Hi-Touch LSI electronic trip unit for sophisticated circuit protection.
  • Long-time, short-time selective and instantaneous protection supports effective system coordination.
  • Exceptional 150 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 100 kA short-time withstand current for 1 s and 3 s supports demanding selective distribution designs.
  • Fixed installation for permanent integration into low-voltage switchboards.
  • Rear flat horizontal terminals facilitate integration with high-current busbar systems.

Key Features

  • ABB SACE Emax 2 E6.2V air circuit breaker.
  • 5000 A rated uninterrupted current.
  • Four-pole configuration.
  • Ekip Hi-Touch LSI electronic trip unit.
  • Long-time overload (L) protection.
  • Short-time selective short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 150 kA ultimate and service short-circuit breaking capacity at 400–440 V AC.
  • 100 kA ultimate and service short-circuit breaking capacity at 690 V AC.
  • 100 kA rated short-time withstand current for 1 s and 3 s.
  • Fixed construction with rear flat horizontal terminals.
  • Four auxiliary change-over contacts with circuit-breaker open/closed position indication.

Advanced High-Fault-Level Circuit Protection for Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 E6.2V provide protection, switching and isolation for high-current low-voltage electrical networks. By detecting overload and short-circuit conditions, the breaker can disconnect the affected circuit to help protect cables, switchgear and connected equipment while supporting dependable operation of the wider distribution system.

The Ekip Hi-Touch LSI trip unit combines long-time, short-time and instantaneous electronic protection with the advanced functionality of the Emax 2 platform. Combined with the E6.2V frame's 5000 A current rating, breaking capacity of up to 150 kA and 100 kA short-time withstand capability, the 1SDA071908R1 is particularly suited to critical high-power distribution applications where fault levels and selectivity requirements are substantial.

Typical Applications

  • Industrial low-voltage main distribution switchboards.
  • Manufacturing plants and large production facilities.
  • Transformer protection and distribution systems.
  • Generator and critical power distribution systems.
  • Data centres and high-availability infrastructure.
  • Utilities and major infrastructure installations.
  • High-fault-level incoming supply protection.
  • Main and feeder circuits requiring selective short-circuit protection.

Technical Specifications

Series SACE Emax 2
Order code / Product ID 1SDA071908R1
EAN 8015644757588
Product type Air circuit breaker
ABB product group Emax2 Air Circuit Breaker
Frame / subtype E6.2V
Short-circuit performance level V
Rated current 5000 A
Rated uninterrupted current (Iu) 5000 A
Number of poles 4
Neutral pole current 50%
Current type AC
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) 150 kA at 400–440 V AC; 130 kA at 500–525 V AC; 100 kA at 690 V AC
Service short-circuit breaking capacity (Ics) 150 kA at 380–440 V AC; 130 kA at 500 V AC; 100 kA at 660–690 V AC
Ics as percentage of Icu 100%
Rated short-time withstand current (Icw) 100 kA for 1 s; 100 kA for 3 s
Trip unit Ekip Hi-Touch LSI
Release type Electronic / solid-state
Protection functions Long-time (L), short-time (S) and instantaneous (I)
Integrated earth-fault protection No
Overload release current setting from 2000 A
Short-time delayed short-circuit release setting from 3000 A
Instantaneous short-circuit release setting from 7500 A
Installation version Fixed
Terminal configuration Rear flat horizontal
Main circuit connection Bolted
Auxiliary contacts 4 change-over contacts
Position indication Circuit breaker open / closed
Power loss 483 W
Electrical durability 3000 cycles at ≤440 V AC; 2000 cycles at 500–690 V AC
Mechanical durability 12000 cycles
Degree of protection IP30
Suitable for IT networks Yes, up to 690 V
Terminal tightening torque 70 N·m
Product dimensions (W × H × D) 888 × 371 × 270 mm
Product net weight 125 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071908R1 used for?

The ABB 1SDA071908R1 is a 5000 A four-pole air circuit breaker used for protection, switching and isolation in high-current, high-fault-level low-voltage power distribution systems.

What protection functions does the Ekip Hi-Touch LSI trip unit provide?

The Ekip Hi-Touch LSI electronic trip unit provides long-time overload (L), short-time selective short-circuit (S) and instantaneous short-circuit (I) protection.

What is the breaking capacity of the ABB E6.2V 5000?

The E6.2V 5000 provides an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC, 130 kA at 500–525 V AC and 100 kA at 690 V AC.

Is the 1SDA071908R1 a fixed or withdrawable circuit breaker?

The 1SDA071908R1 is a fixed-version circuit breaker equipped with rear flat horizontal terminals for integration into low-voltage switchboards.

What is the short-time withstand current of the ABB E6.2V 5000?

The breaker has a rated short-time withstand current of 100 kA for both 1 s and 3 s, supporting selective protection in demanding high-fault-current power distribution systems.

Trusted for High-Performance Power Distribution

ABB SACE Emax 2 air circuit breakers are designed for demanding low-voltage distribution systems where high current capacity, advanced electronic protection, effective selectivity and exceptional short-circuit performance are required.