ABB 1SDA071902R1 Emax 2 E6.2V 5000 Ekip Dip LSI four-pole fixed air circuit breaker rated at 5000 A and 690 V AC with up to 150 kA breaking capacity and adjustable long-time, short-time and instantaneous protection.

SKU: 1SDA071902R1MPN: 1SDA071902R1
Price
List Price £46,814.13 ex VAT
Your Price (ex VAT) Save 25%
£35,110.60 25% OFF
You save £11,703.53 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £35,110.60
Trade pricing is personalised to your account

Manufacturer Lead Time

£35,110.60

Why Choose the ABB E6.2V 5000 Ekip Dip LSI 4p FHR Air Circuit Breaker?

The ABB 1SDA071902R1 is a high-capacity Emax 2 air circuit breaker (ACB) designed for protection, switching and isolation in demanding low-voltage power-distribution systems. Identified as the E6.2V 5000 Ekip Dip LSI 4p FHR, this four-pole fixed circuit breaker combines a substantial 5000 A rated uninterrupted current with ABB’s Ekip Dip LSI electronic trip unit.

As part of the ABB SACE Emax 2 E6.2V series, this breaker provides exceptionally high short-circuit performance for critical industrial and infrastructure installations. The Ekip Dip LSI release provides long-time overload, short-time selective short-circuit and instantaneous short-circuit protection, with straightforward electronic protection settings suited to high-current distribution networks.

With a rated operational voltage of 690 V AC, an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC, 130 kA at 500–525 V AC and 100 kA at 690 V AC, the 1SDA071902R1 is engineered for installations with very high prospective fault currents. Its four-pole fixed construction and rear flat horizontal terminals provide a robust configuration for permanent integration into high-capacity switchboards.

Key Advantages

  • High-capacity ABB Emax 2 E6.2V air circuit breaker for demanding low-voltage power distribution.
  • 5000 A rated uninterrupted current for major industrial and infrastructure installations.
  • 150 kA Icu at 400–440 V AC for systems with exceptionally high prospective fault currents.
  • 130 kA Icu at 500–525 V AC and 100 kA at 690 V AC.
  • 100 kA short-time withstand current for 1 s and 3 s supports demanding selective protection strategies.
  • Ekip Dip LSI electronic trip unit provides adjustable overload and short-circuit protection.
  • Four-pole configuration for switching and protection of three phases and neutral.
  • Fixed construction with rear flat horizontal terminals for permanent switchboard integration.

Key Features

  • ABB SACE Emax 2 E6.2V series.
  • 5000 A rated uninterrupted current.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 150 kA Icu at 400–440 V AC.
  • 130 kA Icu at 500–525 V AC.
  • 100 kA Icu at 690 V AC.
  • 100 kA Icw for 1 s and 3 s.
  • Ekip Dip LSI electronic protection release.
  • Long-time overload, short-time selective and instantaneous short-circuit protection.
  • 2000–5000 A overload release adjustment range.
  • 3000–50000 A short-time delayed short-circuit adjustment range.
  • 7500–75000 A instantaneous short-circuit adjustment range.
  • 4-pole fixed circuit breaker configuration.
  • Rear flat horizontal main terminals with bolt connection.
  • Four auxiliary change-over contacts with circuit-breaker open/closed indication.
  • Suitable for 690 V IT networks.

High-Capacity Power Distribution Protection

The ABB Emax 2 E6.2V platform is designed for high-current low-voltage systems where exceptional short-circuit performance and selective protection are required. With a 5000 A rated uninterrupted current, breaking capacity reaching 150 kA and a 100 kA short-time withstand rating for both one and three seconds, the E6.2V 5000 is well suited to critical distribution positions exposed to very high prospective fault currents.

The Ekip Dip LSI electronic trip unit provides adjustable long-time overload, short-time selective and instantaneous short-circuit protection. These functions help protect transformers, busbars, cables and connected equipment while allowing protection characteristics to be coordinated with other devices in the distribution system for improved selectivity and continuity of service.

Typical Applications

  • Main incomer protection in high-current low-voltage switchboards.
  • Industrial power distribution systems.
  • Transformer and installation protection.
  • Manufacturing and process plants.
  • Data centres and critical power installations.
  • Utility and infrastructure electrical distribution.
  • Large electrical distribution panels and switchboards.
  • Installations with exceptionally high prospective short-circuit currents.

Technical Specifications

Product group Emax 2 Air Circuit Breaker
Range SACE Emax 2
Series E6.2V
ABB order code / MPN 1SDA071902R1
EAN / GTIN 8015644757526
Product type Air circuit breaker
Rated current (In) 5000 A
Rated uninterrupted current (Iu) 5000 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC 150 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 150 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC 130 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 100 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw) 100 kA for 1 s / 100 kA for 3 s
Number of poles 4
Short-circuit performance level V
Trip unit Ekip Dip LSI
Release type Electronic
Protection functions LSI
Overload release adjustment range 2000–5000 A
Short-time delayed short-circuit adjustment range 3000–50000 A
Instantaneous short-circuit adjustment range 7500–75000 A
Integrated earth-fault protection No
Installation Fixed
Terminal connection Rear flat horizontal
Main circuit connection Bolt connection
Recommended main-circuit screw M12
Tightening torque 70 N·m
Auxiliary contacts 4 change-over contacts
Open / closed position indication Yes
Degree of protection IP30
Motor drive integrated No
Motor drive optional Yes
Power loss 483 W
Suitable for IT networks Yes, up to 690 V
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071902R1 used for?

The ABB 1SDA071902R1 is an Emax 2 air circuit breaker designed for high-current low-voltage switching, isolation and circuit protection in industrial, utility and infrastructure power-distribution systems.

What is the current rating of the ABB 1SDA071902R1?

The E6.2V 5000 has a rated uninterrupted current of 5000 A, making it suitable for major high-current electrical distribution systems.

What is the breaking capacity of the E6.2V 5000?

The breaker provides an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC, 130 kA at 500–525 V AC and 100 kA at 690 V AC.

What protection functions does the Ekip Dip LSI provide?

The Ekip Dip LSI electronic trip unit provides adjustable long-time overload, short-time selective short-circuit and instantaneous short-circuit protection. This LSI version does not include integrated earth-fault protection.

How is the ABB 1SDA071902R1 installed?

This model is a four-pole fixed air circuit breaker equipped with rear flat horizontal terminals and bolted main-circuit connections for permanent integration into compatible high-current low-voltage switchboards.

Trusted High-Performance Power Protection

ABB SACE Emax 2 air circuit breakers combine exceptional high-current switching capability with configurable electronic protection, helping demanding industrial and infrastructure installations achieve dependable overload and short-circuit protection while supporting selectivity and continuity of service.