ABB 1SDA071874R1 SACE Emax 2 E6.2V 4000 Ekip Touch LI four-pole fixed air circuit breaker rated at 4000 A and 690 V with 150 kA breaking capacity at 400–440 V AC and electronic long-time and instantaneous protection.
£27,186.01
The ABB E6.2V 4000 Ekip Touch LI 4p FHR, order code 1SDA071874R1, is a high-performance four-pole air circuit breaker (ACB) designed for demanding low-voltage power distribution systems. Part of the ABB SACE Emax 2 family, it combines a 4000 A rated uninterrupted current with the advanced Ekip Touch LI electronic protection release and the exceptional short-circuit capability of the E6.2V frame.
The Ekip Touch LI electronic trip unit provides long-time overload and instantaneous short-circuit protection through an intuitive touch interface. This LI configuration is well suited to applications requiring adjustable electronic protection and advanced monitoring without integrated short-time or earth-fault protection functions.
Rated for operation at up to 690 V AC, the E6.2V 4000 provides an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC, 130 kA at 500–525 V AC and 100 kA at 690 V AC. Its 100 kA short-time withstand current further supports demanding high-current distribution applications. This version is supplied as a fixed four-pole breaker with rear flat horizontal terminals.
The ABB E6.2V frame is engineered for high-current distribution systems where exceptional short-circuit interruption capability is required. With 150 kA Icu at 400–440 V AC and 100 kA Icu at 690 V AC, the breaker can protect major switchboards, busbars, cables and connected equipment in installations with substantial prospective fault currents.
The Ekip Touch LI release combines long-time overload protection with instantaneous short-circuit protection. Its overload setting can be adjusted across 1600–4000 A, while instantaneous protection covers 6000–60000 A. This makes the 1SDA071874R1 particularly suitable where configurable electronic LI protection and very high breaking capacity are required without integrated short-time or earth-fault protection.
| Range | SACE Emax 2 |
|---|---|
| Series | E6.2V |
| ABB order code | 1SDA071874R1 |
| EAN / GTIN | 8015644757243 |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 4000 A |
| Rated voltage | 690 V |
| Number of poles | 4 |
| Short-circuit performance level | V |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 150 kA |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 150 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 150 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500 V AC | 130 kA |
| Ultimate short-circuit breaking capacity (Icu) at 525 V AC | 130 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 100 kA |
| Service short-circuit breaking capacity (Ics) | 100% of Icu |
| Short-time withstand current (Icw) | 100 kA for 1 s; 100 kA for 3 s |
| Trip unit | Ekip Touch LI |
| Release type | Electronic |
| Protection functions | Long-time (L) and instantaneous (I) |
| Overload protection adjustment | 1600–4000 A |
| Instantaneous short-circuit protection adjustment | 6000–60000 A |
| Integrated earth-fault protection | No |
| Mounting type | Fixed |
| Terminal type | Rear flat horizontal |
| Main terminal connection | Bolt |
| Recommended terminal screw size | M12 |
| Recommended tightening torque | 70 N·m |
| Power loss | 309 W |
| Suitable for IT networks | Yes, up to 690 V |
| Standard | IEC |
The ABB 1SDA071874R1 is a four-pole air circuit breaker designed for switching and protecting high-current low-voltage distribution circuits against overload and short-circuit conditions, particularly in installations with high prospective fault currents.
The E6.2V 4000 Ekip Touch LI 4p FHR has a rated uninterrupted current of 4000 A and a rated voltage of 690 V.
The E6.2V provides an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC, 130 kA at 500–525 V AC and 100 kA at 690 V AC. Its short-time withstand current is 100 kA for 1 s.
The Ekip Touch LI electronic trip unit provides long-time overload (L) and instantaneous short-circuit (I) protection. This LI configuration does not include integrated short-time or earth-fault protection.
This model is a fixed four-pole circuit breaker with rear flat horizontal terminals and bolted main connections, designed for integration into compatible low-voltage switchboards and high-capacity power distribution assemblies.
ABB SACE Emax 2 air circuit breakers combine advanced electronic protection with robust switching and exceptional short-circuit performance, providing dependable protection and control for demanding industrial, commercial and infrastructure power distribution systems.