ABB 1SDA071872R1 is a SACE Emax 2 E6.2V 4000 A four-pole fixed air circuit breaker with rear flat horizontal terminals and an Ekip Dip LSI electronic trip unit for high-performance low-voltage power distribution protection.
£27,508.96
The ABB 1SDA071872R1 is a high-performance SACE Emax 2 E6.2V air circuit breaker designed for protection and switching in demanding low-voltage power distribution systems. Configured as an E6.2V 4000 Ekip Dip LSI 4p FHR, it combines a rated uninterrupted current of 4000 A with ABB's Ekip Dip LSI solid-state electronic trip unit.
This four-pole fixed circuit breaker provides comprehensive LSI protection functions, covering long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. The Ekip Dip release provides straightforward adjustable electronic protection, making the breaker well suited to high-current distribution systems requiring dependable fault protection and selective coordination.
The E6.2V high-performance frame provides a rated ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC, 130 kA at 500–525 V AC and 100 kA at 690 V AC, together with a rated short-time withstand current of 100 kA for 1 s and 3 s. Its fixed four-pole construction features rear flat horizontal terminals and four change-over auxiliary contacts for integration into high-current switchboards.
Air circuit breakers such as the ABB SACE Emax 2 protect high-current low-voltage electrical networks against overloads and short circuits while providing switching and isolation functions within power distribution assemblies. The E6.2V frame combines a 4000 A continuous-current rating with exceptional fault interruption capability, including 150 kA ultimate breaking capacity at 400–440 V AC.
The Ekip Dip LSI electronic trip unit provides adjustable long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. Combined with the robust Emax 2 architecture and 100 kA short-time withstand capability, the 1SDA071872R1 provides dependable protection for main distribution switchboards, high-current feeders and electrical systems requiring high breaking capacity and selective fault coordination.
| Series | SACE Emax 2 |
|---|---|
| Frame | E6.2V |
| ABB order code | 1SDA071872R1 |
| Product type | Air circuit breaker |
| Rated current (In) | 4000 A |
| Rated uninterrupted current (Iu) | 4000 A |
| Number of poles | 4 |
| Neutral pole current | 50% of Iu |
| Trip unit | Ekip Dip LSI |
| Release type | Solid-state electronic |
| Protection functions | LSI |
| Overload release current setting | 1600–4000 A |
| Short-time delayed short-circuit adjustment | 2400–40000 A |
| Instantaneous short-circuit adjustment | 6000–60000 A |
| Integrated earth-fault protection | No |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 400–440 V AC | 150 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC | 130 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 100 kA |
| Rated service short-circuit breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw), 1 s | 100 kA |
| Rated short-time withstand current (Icw), 3 s | 100 kA |
| Mounting version | Fixed |
| Terminal arrangement | Rear flat horizontal |
| Main circuit connection | Bolt connection |
| Auxiliary contacts | 4 change-over contacts |
| Circuit-breaker position indication | Open/closed |
| Motor drive | Optional |
| Degree of protection | IP30 |
| Power loss | 309 W |
| Mechanical durability | 12000 cycles |
| Electrical durability | 4000 cycles |
| Product net width | 888 mm |
| Product net height | 371 mm |
| Product net depth | 270 mm |
| Product net weight | 125 kg |
| EAN | 8015644757229 |
| Standard | IEC 60947-2 |
| Product group | Emax2 Air Circuit Breaker |
The ABB 1SDA071872R1 is a 4000 A four-pole air circuit breaker designed for protection and switching in high-current low-voltage power distribution systems.
The circuit breaker is fitted with an Ekip Dip LSI solid-state electronic trip unit providing adjustable overload and short-circuit protection.
The LSI configuration provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.
The E6.2V circuit breaker has a rated uninterrupted current of 4000 A, with overload protection adjustable from 1600 A to 4000 A.
The E6.2V 4000 configuration has a rated ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC, 130 kA at 500–525 V AC and 100 kA at 690 V AC.
No. This version uses an Ekip Dip LSI trip unit, providing long-time, short-time and instantaneous protection without an integrated G earth-fault protection function.
This model is a fixed four-pole circuit breaker equipped with rear flat horizontal terminals.
ABB SACE Emax 2 air circuit breakers are engineered for reliable protection and switching of demanding low-voltage electrical networks, combining high current-carrying capability, exceptional fault interruption performance and configurable electronic protection for industrial, commercial and infrastructure power distribution systems.
We use cookies