ABB 1SDA071870R1 Emax 2 E6.2H 4000 is a 4000 A four-pole fixed air circuit breaker with Ekip G Hi-Touch LSIG electronic protection, 100 kA breaking capacity at 400 V AC and rear horizontal terminals for demanding low-voltage power distribution and generator applications.

SKU: 1SDA071870R1MPN: 1SDA071870R1
Price
List Price £29,234.44 ex VAT
Your Price (ex VAT) Save 25%
£21,925.83 25% OFF
You save £7,308.61 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £21,925.83
Trade pricing is personalised to your account

Manufacturer Lead Time

£21,925.83

Why Choose the ABB E6.2H 4000 Ekip G Hi-Touch LSIG 4p FHR Air Circuit Breaker?

The ABB E6.2H 4000 Ekip G Hi-Touch LSIG 4p FHR, order code 1SDA071870R1, is a high-performance four-pole air circuit breaker (ACB) designed for protection, switching and isolation in demanding low-voltage power distribution systems. As part of the advanced ABB SACE Emax 2 series, it combines a substantial 4000 A rated current with sophisticated electronic protection and high short-circuit performance for critical industrial, commercial and infrastructure installations.

This Emax 2 circuit breaker incorporates the Ekip G Hi-Touch LSIG electronic trip unit, providing long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection. The advanced Ekip G Hi-Touch platform is designed for sophisticated power protection and monitoring applications, helping engineers achieve accurate protection coordination and dependable operation across complex electrical distribution networks.

The E6.2H 4000 is a fixed, four-pole breaker with rear horizontal terminals. It operates at up to 690 V AC and provides an ultimate short-circuit breaking capacity of 100 kA at 400 V AC, making it suitable for high-current incoming supplies, generator systems, feeders and critical main distribution switchboards.

Key Advantages

  • High-capacity 4000 A air circuit breaker for demanding low-voltage distribution systems.
  • Four-pole configuration for comprehensive switching, protection and isolation.
  • Advanced Ekip G Hi-Touch LSIG electronic trip unit for sophisticated circuit protection.
  • Long-time, short-time, instantaneous and earth-fault protection in a single integrated trip unit.
  • 100 kA ultimate short-circuit breaking capacity at 400 V AC.
  • Advanced protection capabilities support selectivity and coordination in complex distribution networks.
  • Fixed installation for permanent integration into low-voltage switchboards.
  • Rear horizontal terminals facilitate connection to high-current busbar systems.

Key Features

  • ABB SACE Emax 2 E6.2H air circuit breaker.
  • 4000 A rated uninterrupted current.
  • Four-pole configuration.
  • Ekip G Hi-Touch LSIG electronic trip unit.
  • Long-time overload (L) protection.
  • Short-time selective short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • Integrated earth-fault (G) protection.
  • Overload protection adjustable from 1600–4000 A.
  • Short-time short-circuit protection adjustable from 2400–40000 A.
  • Instantaneous short-circuit protection adjustable from 6000–60000 A.
  • 690 V AC rated operational voltage.
  • 100 kA ultimate short-circuit breaking capacity at 400 V AC.
  • Fixed construction with rear horizontal terminals.

Advanced Protection for Critical Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 E6.2H provide protection, switching and isolation for high-current low-voltage electrical networks. By detecting overloads, short circuits and earth faults, the breaker can disconnect the affected circuit to help protect cables, switchgear and connected equipment while supporting dependable operation of the wider distribution system.

The Ekip G Hi-Touch LSIG trip unit combines comprehensive electronic protection with advanced functionality suited to demanding power distribution and generator applications. Together with the E6.2H frame's 4000 A current rating and 100 kA short-circuit breaking performance at 400 V AC, this makes the 1SDA071870R1 a powerful solution for critical high-current electrical installations.

Typical Applications

  • Industrial low-voltage main distribution switchboards.
  • Manufacturing plants and production facilities.
  • Generator and generator-protection systems.
  • Commercial building electrical distribution systems.
  • Data centres and critical power infrastructure.
  • Utilities and infrastructure installations.
  • Transformer and high-current distribution systems.
  • Main and feeder circuits requiring comprehensive LSIG protection.

Technical Specifications

Series SACE Emax 2
Order code / Product ID 1SDA071870R1
Product type Air circuit breaker
Frame / subtype E6.2H
Performance level H
Rated current 4000 A
Rated uninterrupted current (Iu) 4000 A
Number of poles 4
Current type AC
Rated operational voltage (Ue) up to 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50 / 60 Hz
Ultimate short-circuit breaking capacity (Icu) 100 kA at 400 V AC
Trip unit Ekip G Hi-Touch LSIG
Release type Electronic
Protection functions Long-time (L), short-time (S), instantaneous (I) and earth-fault (G)
Overload release current setting 1600–4000 A
Short-time delayed short-circuit release setting 2400–40000 A
Instantaneous short-circuit release setting 6000–60000 A
Integrated earth-fault protection Yes
Installation version Fixed
Terminal configuration Rear horizontal
Main circuit connection Bolted
Auxiliary contacts 4 change-over contacts
Protection rating IP30
Power loss 309 W
GTIN / EAN 8015644757205
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071870R1 used for?

The ABB 1SDA071870R1 is a 4000 A four-pole air circuit breaker used for protection, switching and isolation in high-current low-voltage power distribution and generator applications.

What protection functions does the Ekip G Hi-Touch LSIG trip unit provide?

The Ekip G Hi-Touch LSIG electronic trip unit provides long-time overload (L), short-time selective short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection.

What is the breaking capacity of the ABB E6.2H 4000?

The E6.2H 4000 provides an ultimate short-circuit breaking capacity of 100 kA at 400 V AC, making it suitable for demanding high-fault-current distribution systems.

Is the 1SDA071870R1 a fixed or withdrawable circuit breaker?

The 1SDA071870R1 is a fixed-version circuit breaker equipped with rear horizontal terminals for integration into low-voltage switchboards.

What does LSIG protection mean on this Emax 2 circuit breaker?

LSIG denotes long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, providing comprehensive electronic protection for demanding low-voltage distribution systems.

Trusted for Critical High-Current Power Distribution

ABB SACE Emax 2 air circuit breakers are designed for reliable protection, switching and management of low-voltage electrical systems, combining high-current capability with advanced electronic protection for demanding industrial, generator, commercial and infrastructure applications.