1SDA071863R1 ABB E6.2H 4000 Ekip Dip LSIG 4p FHR Air Circuit Breaker

1SDA071863R1 ABB E6.2H 4000 Ekip Dip LSIG 4p FHR Air Circuit Breaker

ABB 1SDA071863R1 Emax 2 E6.2H 4000 Ekip Dip LSIG four-pole fixed air circuit breaker rated at 4000 A and 690 V AC with 100 kA breaking capacity at 440 V AC and comprehensive overload, short-circuit and earth-fault protection.

SKU: 1SDA071863R1MPN: 1SDA071863R1
Price
List Price £30,099.76 ex VAT
Your Price (ex VAT) Save 25%
£22,574.82 25% OFF
You save £7,524.94 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £22,574.82
Trade pricing is personalised to your account

Manufacturer Lead Time

£22,574.82

Why Choose the ABB E6.2H 4000 Ekip Dip LSIG 4p FHR Air Circuit Breaker?

The ABB 1SDA071863R1 is a high-performance Emax 2 air circuit breaker (ACB) designed for protection, switching and isolation in demanding low-voltage power-distribution systems. Identified as the E6.2H 4000 Ekip Dip LSIG 4p FHR, this four-pole fixed circuit breaker combines a 4000 A rated current with ABB’s Ekip Dip LSIG solid-state electronic trip unit.

As part of the ABB SACE Emax 2 series, the E6.2H provides substantial short-circuit performance for critical industrial and infrastructure installations. The Ekip Dip LSIG release provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection, delivering comprehensive electronic protection for high-current electrical networks.

With a rated operational voltage of 690 V AC, an ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a short-time withstand current of 100 kA for 1 s, the 1SDA071863R1 is engineered for installations with high prospective fault currents. Its four-pole fixed construction and rear horizontal terminals provide a robust configuration for permanent integration into high-current low-voltage switchboards and distribution assemblies.

Key Advantages

  • High-performance ABB Emax 2 air circuit breaker for demanding low-voltage power distribution.
  • 4000 A rated current for large industrial, commercial and infrastructure installations.
  • 100 kA Icu at 440 V AC for dependable interruption of high prospective fault currents.
  • 100 kA Icw for 1 s supports demanding selective protection strategies.
  • Four-pole configuration for switching and protection of three phases and neutral.
  • Ekip Dip LSIG electronic trip unit with overload, short-circuit and earth-fault protection.
  • Fixed construction with rear horizontal terminals for permanent switchboard installation.

Key Features

  • ABB SACE Emax 2 E6.2H series.
  • 4000 A rated uninterrupted current.
  • 690 V AC rated operational voltage.
  • 100 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 100 kA rated short-time withstand current for 1 s.
  • Ekip Dip LSIG solid-state electronic protection release.
  • Long-time overload, short-time selective, instantaneous and earth-fault protection functions.
  • Protection settings configured through the Ekip Dip interface.
  • 4-pole fixed circuit breaker configuration.
  • Rear horizontal main terminals.
  • Fitted with 4 auxiliary contacts.
  • Circuit-breaker open/closed position indication.
  • IP30 degree of protection.
  • Optional motor-drive capability.

Comprehensive High-Capacity Power Distribution Protection

Air circuit breakers such as the ABB Emax 2 E6.2H provide switching, isolation and protection for high-current low-voltage electrical systems. The E6.2H 4000 combines a substantial 4000 A current rating with 100 kA short-circuit breaking capability at 440 V AC and a 100 kA one-second withstand rating, making it particularly suitable for critical distribution points with high prospective fault currents.

The Ekip Dip LSIG electronic trip unit provides long-time overload, short-time selective, instantaneous short-circuit and earth-fault protection. These protection functions allow the breaker to safeguard transformers, busbars, cables and connected equipment against a broad range of electrical faults while supporting selective coordination and continuity of service.

Typical Applications

  • Main incomer protection in high-current low-voltage switchboards.
  • Industrial power distribution systems.
  • Transformer and installation protection.
  • Manufacturing and process plants.
  • Data centres and critical power installations.
  • Commercial and infrastructure electrical distribution.
  • Large electrical distribution panels and switchboards.
  • High-current installations requiring integrated earth-fault protection.

Technical Specifications

Product group Emax 2 Air Circuit Breaker
Range SACE Emax 2
Series E6.2H
ABB order code / MPN 1SDA071863R1
EAN 8015644757137
Product type Air circuit breaker
Rated current 4000 A
Rated uninterrupted current (Iu) 4000 A
Rated operational voltage 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated short-time withstand current (Icw) 100 kA for 1 s
Number of poles 4
Short-circuit performance level H
Trip unit Ekip Dip LSIG
Release type Solid-state electronic
Protection functions LSIG
Long-time overload protection Yes
Short-time selective short-circuit protection Yes
Instantaneous short-circuit protection Yes
Earth-fault protection Yes
Installation Fixed
Terminal connection Rear horizontal
Main circuit connection Bolt connection
Current type AC
Auxiliary contacts 4 change-over contacts
Position indication Circuit breaker open / closed
Degree of protection IP30
Motor drive Optional
Electrical durability 4000 cycles
Mechanical durability 12,000 cycles
Dimensions (W × H × D) 888 × 371 × 270 mm
Net weight 112 kg
Standards / approvals IEC
Country of origin Italy

Frequently Asked Questions

What is the ABB 1SDA071863R1 used for?

The ABB 1SDA071863R1 is an Emax 2 air circuit breaker designed for high-current low-voltage switching, isolation and circuit protection in industrial, commercial and infrastructure power-distribution systems.

What is the current rating of the ABB 1SDA071863R1?

The E6.2H 4000 has a rated uninterrupted current of 4000 A, making it suitable for large high-current electrical distribution systems.

What is the breaking capacity of the E6.2H 4000?

The E6.2H 4000 provides an ultimate short-circuit breaking capacity of 100 kA at 440 V AC together with a rated short-time withstand current of 100 kA for 1 s.

What protection functions does the Ekip Dip LSIG provide?

The Ekip Dip LSIG electronic trip unit provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection for comprehensive electrical system protection.

How is the ABB 1SDA071863R1 installed?

This model is a four-pole fixed air circuit breaker equipped with rear horizontal terminals for permanent integration into compatible low-voltage switchboards and power-distribution assemblies.

Trusted High-Performance Power Protection

ABB SACE Emax 2 air circuit breakers combine high-current switching capability with configurable electronic protection, helping demanding industrial and infrastructure installations achieve dependable overload, short-circuit and earth-fault protection while supporting selectivity and continuity of service.