ABB 1SDA071863R1 Emax 2 E6.2H 4000 Ekip Dip LSIG four-pole fixed air circuit breaker rated at 4000 A and 690 V AC with 100 kA breaking capacity at 440 V AC and comprehensive overload, short-circuit and earth-fault protection.
£22,574.82
The ABB 1SDA071863R1 is a high-performance Emax 2 air circuit breaker (ACB) designed for protection, switching and isolation in demanding low-voltage power-distribution systems. Identified as the E6.2H 4000 Ekip Dip LSIG 4p FHR, this four-pole fixed circuit breaker combines a 4000 A rated current with ABB’s Ekip Dip LSIG solid-state electronic trip unit.
As part of the ABB SACE Emax 2 series, the E6.2H provides substantial short-circuit performance for critical industrial and infrastructure installations. The Ekip Dip LSIG release provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection, delivering comprehensive electronic protection for high-current electrical networks.
With a rated operational voltage of 690 V AC, an ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a short-time withstand current of 100 kA for 1 s, the 1SDA071863R1 is engineered for installations with high prospective fault currents. Its four-pole fixed construction and rear horizontal terminals provide a robust configuration for permanent integration into high-current low-voltage switchboards and distribution assemblies.
Air circuit breakers such as the ABB Emax 2 E6.2H provide switching, isolation and protection for high-current low-voltage electrical systems. The E6.2H 4000 combines a substantial 4000 A current rating with 100 kA short-circuit breaking capability at 440 V AC and a 100 kA one-second withstand rating, making it particularly suitable for critical distribution points with high prospective fault currents.
The Ekip Dip LSIG electronic trip unit provides long-time overload, short-time selective, instantaneous short-circuit and earth-fault protection. These protection functions allow the breaker to safeguard transformers, busbars, cables and connected equipment against a broad range of electrical faults while supporting selective coordination and continuity of service.
| Product group | Emax 2 Air Circuit Breaker |
|---|---|
| Range | SACE Emax 2 |
| Series | E6.2H |
| ABB order code / MPN | 1SDA071863R1 |
| EAN | 8015644757137 |
| Product type | Air circuit breaker |
| Rated current | 4000 A |
| Rated uninterrupted current (Iu) | 4000 A |
| Rated operational voltage | 690 V AC |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 100 kA |
| Rated short-time withstand current (Icw) | 100 kA for 1 s |
| Number of poles | 4 |
| Short-circuit performance level | H |
| Trip unit | Ekip Dip LSIG |
| Release type | Solid-state electronic |
| Protection functions | LSIG |
| Long-time overload protection | Yes |
| Short-time selective short-circuit protection | Yes |
| Instantaneous short-circuit protection | Yes |
| Earth-fault protection | Yes |
| Installation | Fixed |
| Terminal connection | Rear horizontal |
| Main circuit connection | Bolt connection |
| Current type | AC |
| Auxiliary contacts | 4 change-over contacts |
| Position indication | Circuit breaker open / closed |
| Degree of protection | IP30 |
| Motor drive | Optional |
| Electrical durability | 4000 cycles |
| Mechanical durability | 12,000 cycles |
| Dimensions (W × H × D) | 888 × 371 × 270 mm |
| Net weight | 112 kg |
| Standards / approvals | IEC |
| Country of origin | Italy |
The ABB 1SDA071863R1 is an Emax 2 air circuit breaker designed for high-current low-voltage switching, isolation and circuit protection in industrial, commercial and infrastructure power-distribution systems.
The E6.2H 4000 has a rated uninterrupted current of 4000 A, making it suitable for large high-current electrical distribution systems.
The E6.2H 4000 provides an ultimate short-circuit breaking capacity of 100 kA at 440 V AC together with a rated short-time withstand current of 100 kA for 1 s.
The Ekip Dip LSIG electronic trip unit provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection for comprehensive electrical system protection.
This model is a four-pole fixed air circuit breaker equipped with rear horizontal terminals for permanent integration into compatible low-voltage switchboards and power-distribution assemblies.
ABB SACE Emax 2 air circuit breakers combine high-current switching capability with configurable electronic protection, helping demanding industrial and infrastructure installations achieve dependable overload, short-circuit and earth-fault protection while supporting selectivity and continuity of service.