1SDA071849R1 ABB E4.2H 4000 Ekip Hi-Touch LSIG 4p FHR Air Circuit Breaker

1SDA071849R1 ABB E4.2H 4000 Ekip Hi-Touch LSIG 4p FHR Air Circuit Breaker

ABB 1SDA071849R1 Emax 2 E4.2H 4000 Ekip Hi-Touch LSIG four-pole fixed air circuit breaker rated at 4000 A and 690 V AC with 100 kA breaking capacity at 440 V AC and advanced overload, short-circuit and earth-fault protection.

SKU: 1SDA071849R1MPN: 1SDA071849R1
Price
List Price £34,730.52 ex VAT
Your Price (ex VAT) Save 25%
£26,047.89 25% OFF
You save £8,682.63 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £26,047.89
Trade pricing is personalised to your account

Manufacturer Lead Time

£26,047.89

Why Choose the ABB E4.2H 4000 Ekip Hi-Touch LSIG 4p FHR Air Circuit Breaker?

The ABB 1SDA071849R1 is a high-performance Emax 2 air circuit breaker (ACB) designed for advanced protection, switching, measurement and control in demanding low-voltage electrical distribution systems. Identified as the E4.2H 4000 Ekip Hi-Touch LSIG 4p FHR, this four-pole fixed circuit breaker combines a 4000 A rated current with ABB’s advanced Ekip Hi-Touch LSIG electronic trip unit.

As part of the ABB SACE Emax 2 series, the E4.2H provides high short-circuit performance together with sophisticated electronic protection and power-management capabilities. The Ekip Hi-Touch LSIG release provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection, delivering comprehensive protection for critical electrical distribution equipment.

With a rated operational voltage of up to 690 V AC, an ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a short-time withstand current of 85 kA for 1 s, the 1SDA071849R1 is engineered for high-current installations with substantial prospective fault levels. Its four-pole fixed construction and rear flat horizontal terminals provide a robust configuration for permanent integration into industrial and infrastructure switchboards.

Key Advantages

  • High-performance ABB Emax 2 air circuit breaker for demanding low-voltage power distribution.
  • 4000 A rated current for large industrial and infrastructure installations.
  • 100 kA Icu at 440 V AC for installations with high prospective fault currents.
  • 85 kA short-time withstand current for 1 s supports selective protection strategies.
  • Four-pole configuration for switching and protection of three phases and neutral.
  • Advanced Ekip Hi-Touch LSIG electronic trip unit with overload, short-circuit and earth-fault protection.
  • Advanced measurement, monitoring and power-management capabilities for modern electrical distribution systems.
  • Fixed construction with rear flat horizontal terminals for switchboard integration.

Key Features

  • ABB SACE Emax 2 E4.2H series.
  • 4000 A rated uninterrupted current.
  • 690 V AC rated operational voltage.
  • 100 kA Icu at 440 V AC.
  • 85 kA rated short-time withstand current for 1 s.
  • Ekip Hi-Touch LSIG electronic protection release.
  • Long-time overload, short-time selective, instantaneous and earth-fault protection functions.
  • Advanced electrical measurement and power-management functionality.
  • Touch interface for protection settings, measurements and operating information.
  • 4-pole fixed circuit breaker configuration.
  • Rear flat horizontal main terminals.
  • Designed for integration with automation and energy-management systems.

Advanced High-Current Protection and Power Management

Air circuit breakers such as the ABB Emax 2 E4.2H provide switching, isolation and protection for high-current low-voltage electrical systems. The E4.2H 4000 combines a substantial 4000 A current rating with an ultimate breaking capacity of 100 kA at 440 V AC, making it suitable for main distribution positions and other critical points where high prospective short-circuit currents can occur.

The Ekip Hi-Touch LSIG electronic trip unit provides configurable long-time overload, short-time selective, instantaneous short-circuit and earth-fault protection while supporting the advanced measurement and power-management capabilities of the Emax 2 platform. This combination helps protect transformers, busbars, cables and connected equipment while supporting selectivity, continuity of service and integration with modern electrical automation systems.

Typical Applications

  • Main incomer protection in low-voltage switchboards.
  • Industrial power distribution systems.
  • Transformer and installation protection.
  • Manufacturing and process plants.
  • Data centres and critical power installations.
  • Commercial and infrastructure electrical distribution.
  • Automation and energy-management systems.
  • High-current installations requiring integrated earth-fault protection.

Technical Specifications

Product group Emax 2 Air Circuit Breaker
Range SACE Emax 2
Series E4.2H
ABB order code / MPN 1SDA071849R1
EAN 8015644756994
Product type Air circuit breaker
Rated current (In) 4000 A
Rated uninterrupted current (Iu) 4000 A
Rated operational voltage (Ue) 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated short-time withstand current (Icw) 85 kA for 1 s
Number of poles 4
Short-circuit performance level H
Trip unit Ekip Hi-Touch LSIG
Release type Electronic
Protection functions LSIG
Long-time overload protection Yes
Short-time selective short-circuit protection Yes
Instantaneous short-circuit protection Yes
Earth-fault protection Yes
Overload release adjustment range 1600–4000 A
Short-time short-circuit adjustment range 2400–40000 A
Installation Fixed
Terminal connection Rear flat horizontal
Main circuit connection Bolt connection
Current type AC
Standard IEC
Country of origin Italy

Frequently Asked Questions

What is the ABB 1SDA071849R1 used for?

The ABB 1SDA071849R1 is an Emax 2 air circuit breaker designed for high-current low-voltage switching, protection, monitoring and power management in industrial, commercial and infrastructure electrical distribution systems.

What is the current rating of the ABB 1SDA071849R1?

The E4.2H 4000 has a rated uninterrupted current of 4000 A, making it suitable for large high-current electrical distribution systems.

What is the breaking capacity of the E4.2H 4000?

The E4.2H 4000 provides an ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 85 kA for 1 s.

What protection functions does the Ekip Hi-Touch LSIG provide?

The Ekip Hi-Touch LSIG electronic trip unit provides long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection, together with advanced measurement and power-management capabilities.

How is the ABB 1SDA071849R1 installed?

This model is a four-pole fixed air circuit breaker equipped with rear flat horizontal terminals for permanent integration into compatible low-voltage switchboards and power-distribution assemblies.

Trusted High-Performance Power Protection

ABB SACE Emax 2 air circuit breakers combine high-current switching capability with advanced electronic protection, measurement and power-management functionality, helping demanding industrial and infrastructure installations achieve dependable overload, short-circuit and earth-fault protection with improved selectivity and continuity of service.