1SDA071845R1 ABB E4.2H 4000 Ekip Touch LSI 4P FHR Air Circuit Breaker

1SDA071845R1 ABB E4.2H 4000 Ekip Touch LSI 4P FHR Air Circuit Breaker

ABB 1SDA071845R1 is a SACE Emax 2 E4.2H 4000 A four-pole fixed air circuit breaker with rear horizontal terminals and an Ekip Touch LSI electronic trip unit for advanced low-voltage power distribution protection.

SKU: 1SDA071845R1MPN: 1SDA071845R1
Price
List Price £30,345.38 ex VAT
Your Price (ex VAT) Save 25%
£22,759.04 25% OFF
You save £7,586.35 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £22,759.04
Trade pricing is personalised to your account

Manufacturer Lead Time

£22,759.04

Why Choose the ABB 1SDA071845R1 Emax 2 Air Circuit Breaker?

The ABB 1SDA071845R1 is a high-performance SACE Emax 2 E4.2H air circuit breaker designed for protection and switching in demanding low-voltage power distribution systems. Configured as an E4.2H 4000 Ekip Touch LSI 4p FHR, it combines a rated uninterrupted current of 4000 A with ABB's advanced Ekip Touch LSI solid-state electronic trip unit.

This four-pole fixed circuit breaker provides comprehensive LSI protection functions, covering long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. The Ekip Touch release provides configurable electronic protection through an intuitive interface, supporting selective coordination and dependable protection in sophisticated industrial, commercial and infrastructure distribution systems.

With an E4.2H high-performance frame, the 1SDA071845R1 provides a rated ultimate short-circuit breaking capacity of 100 kA at 400–440 V AC and 85 kA at 500–690 V AC, together with a rated short-time withstand current of 85 kA for 1 s. Its fixed four-pole construction features rear flat horizontal terminals and four change-over auxiliary contacts for integration into high-current switchboards.

Key Advantages

  • High-performance ABB SACE Emax 2 E4.2H air circuit breaker for demanding low-voltage distribution systems.
  • 4000 A rated uninterrupted current for high-current electrical installations.
  • 100 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 85 kA short-time withstand current for 1 s for robust fault-current performance.
  • Advanced Ekip Touch LSI electronic trip unit for adjustable overload and short-circuit protection.
  • Four-pole fixed configuration with rear flat horizontal terminals for switchboard integration.

Key Features

  • ABB SACE Emax 2 E4.2H series.
  • 4000 A rated uninterrupted current (Iu).
  • Four-pole configuration with 100% neutral pole current.
  • Fixed mounting construction.
  • Rear flat horizontal terminals (FHR).
  • Ekip Touch LSI solid-state electronic trip unit.
  • LSI protection for long-time overload, short-time delayed short-circuit and instantaneous short-circuit conditions.
  • 690 V AC rated operational voltage.
  • 100 kA Icu at 400–440 V AC and 85 kA Icu at 500–690 V AC.
  • Suitable for use on 690 V IT networks.

Advanced LSI Protection for Low-Voltage Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 protect high-current low-voltage electrical networks against overloads and short circuits while providing switching and isolation functions within power distribution assemblies. The E4.2H frame combines a 4000 A continuous-current rating with high fault interruption and short-time withstand capability for demanding industrial, commercial and infrastructure installations.

The Ekip Touch LSI electronic trip unit provides configurable long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. Combined with the robust Emax 2 architecture, the 1SDA071845R1 provides dependable protection for main distribution switchboards, high-current feeders and electrical systems requiring high breaking capacity, selective coordination and advanced electronic protection.

Typical Applications

  • Main incoming protection for low-voltage switchboards.
  • Industrial power distribution systems.
  • High-current feeder protection.
  • Manufacturing and process industry electrical systems.
  • Commercial and infrastructure power distribution.
  • Installations requiring configurable short-circuit selectivity and high breaking capacity.

Technical Specifications

Series SACE Emax 2
Frame E4.2H
ABB order code 1SDA071845R1
Product type Air circuit breaker
Rated current (In) 4000 A
Rated uninterrupted current (Iu) 4000 A
Number of poles 4
Neutral pole current 100% of Iu
Trip unit Ekip Touch LSI
Release type Electronic
Protection functions LSI
Overload release current setting from 1600 A
Short-time delayed short-circuit adjustment from 2400 A
Instantaneous short-circuit adjustment from 6000 A
Integrated earth-fault protection No
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 400–440 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500–690 V AC 85 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw), 1 s 85 kA
Rated short-time withstand current (Icw), 3 s 75 kA
Mounting version Fixed
Terminal arrangement Rear flat horizontal
Main circuit connection Bolt connection
Auxiliary contacts 4 change-over contacts
Motor drive Optional
Degree of protection IP30
Power loss 465 W
Mechanical durability 15000 cycles
Electrical durability up to 440 V 5000 cycles
Electrical durability at 500–690 V 4000 cycles
Product net width 510 mm
Product net height 371 mm
Product net depth 270 mm
Product net weight 70 kg
EAN 8015644756956
Standard IEC 60947-2
Product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA071845R1 used for?

The ABB 1SDA071845R1 is a 4000 A four-pole air circuit breaker designed for protection and switching in high-current low-voltage power distribution systems.

What trip unit is fitted to the ABB 1SDA071845R1?

The circuit breaker is fitted with an Ekip Touch LSI electronic trip unit for configurable overload and short-circuit protection.

What protection functions does the Ekip Touch LSI provide?

The LSI configuration provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.

What is the current rating of the ABB 1SDA071845R1?

The E4.2H circuit breaker has a rated uninterrupted current of 4000 A.

What is the breaking capacity of the ABB 1SDA071845R1?

The E4.2H 4000 configuration has a rated ultimate short-circuit breaking capacity of 100 kA at 400–440 V AC and 85 kA at 500–690 V AC.

Does the ABB 1SDA071845R1 include earth-fault protection?

No. This version uses an Ekip Touch LSI trip unit, providing long-time, short-time and instantaneous protection without an integrated G earth-fault protection function.

Is the ABB 1SDA071845R1 fixed or withdrawable?

This model is a fixed four-pole circuit breaker equipped with rear flat horizontal terminals.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers are engineered for reliable protection and switching of demanding low-voltage electrical networks, combining high current-carrying capability, robust fault interruption performance and configurable electronic protection for industrial, commercial and infrastructure power distribution systems.