1SDA071836R1 ABB E4.2S 4000 Ekip Touch LSIG 4p FHR Air Circuit Breaker

1SDA071836R1 ABB E4.2S 4000 Ekip Touch LSIG 4p FHR Air Circuit Breaker

ABB 1SDA071836R1 Emax 2 E4.2S 4000 Ekip Touch LSIG four-pole fixed air circuit breaker rated at 4000 A and 690 V AC with up to 85 kA breaking capacity and advanced overload, short-circuit and earth-fault protection.

SKU: 1SDA071836R1MPN: 1SDA071836R1
Price
List Price £29,526.82 ex VAT
Your Price (ex VAT) Save 25%
£22,145.12 25% OFF
You save £7,381.71 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £22,145.12
Trade pricing is personalised to your account

Manufacturer Lead Time

£22,145.12

Why Choose the ABB E4.2S 4000 Ekip Touch LSIG 4p FHR Air Circuit Breaker?

The ABB 1SDA071836R1 is a high-current Emax 2 air circuit breaker (ACB) designed for protection, switching and control in demanding low-voltage electrical distribution systems. Identified as the E4.2S 4000 Ekip Touch LSIG 4p FHR, this four-pole fixed circuit breaker combines a 4000 A rated current with ABB’s advanced Ekip Touch LSIG electronic trip unit.

As part of the ABB SACE Emax 2 series, the E4.2S provides high short-circuit performance together with configurable electronic protection and monitoring. The Ekip Touch LSIG release provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, enabling comprehensive protection and coordination across industrial and commercial power-distribution systems.

With a rated operational voltage of up to 690 V AC, an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC, the 1SDA071836R1 is suitable for high-current installations requiring dependable fault interruption. Its four-pole fixed construction and rear flat horizontal terminals provide a robust configuration for permanent integration into low-voltage switchboards and distribution assemblies.

Key Advantages

  • High-current ABB Emax 2 air circuit breaker for demanding low-voltage power distribution.
  • 4000 A rated current for large industrial and infrastructure installations.
  • 85 kA Icu at 400–440 V AC for high fault-level applications.
  • Four-pole configuration for switching and protection of three phases and neutral.
  • Advanced Ekip Touch LSIG electronic trip unit with overload, short-circuit and earth-fault protection.
  • 66 kA short-time withstand current supports selective protection strategies.
  • Fixed construction with rear flat horizontal terminals for switchboard integration.

Key Features

  • ABB SACE Emax 2 E4.2S series.
  • 4000 A rated uninterrupted current.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 85 kA Icu at 400–440 V AC.
  • 66 kA Icu at 500–690 V AC.
  • 66 kA rated short-time withstand current.
  • Ekip Touch LSIG electronic protection release.
  • Long-time, short-time, instantaneous and earth-fault protection functions.
  • Touch interface for protection settings and operating information.
  • 4-pole fixed circuit breaker configuration.
  • Rear flat horizontal main terminals.
  • Designed in accordance with IEC 60947-2 requirements.

Advanced High-Current Circuit Protection

Air circuit breakers such as the ABB Emax 2 E4.2S provide switching, isolation and protection for high-current low-voltage electrical systems. The E4.2S 4000 combines a substantial 4000 A current rating with high short-circuit interruption capability, making it suitable for main distribution positions and other critical points within industrial and infrastructure switchboards.

The Ekip Touch LSIG electronic trip unit provides adjustable protection against long-time overloads, short-time and instantaneous short circuits and earth faults. These protection functions support coordinated and selective distribution-system design while helping protect cables, busbars, transformers and connected equipment against damaging electrical faults.

Typical Applications

  • Main incomer protection in low-voltage switchboards.
  • Industrial power distribution systems.
  • Transformer and installation protection.
  • Manufacturing and process plants.
  • Commercial and infrastructure electrical distribution.
  • Data centres and critical power installations.
  • Large electrical distribution panels and switchboards.
  • High-current installations requiring integrated earth-fault protection.

Technical Specifications

Product group Emax 2 Air Circuit Breaker
Range SACE Emax 2
Series E4.2S
ABB order code / MPN 1SDA071836R1
Product type Air circuit breaker
Rated current (In) 4000 A
Rated uninterrupted current (Iu) 4000 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw) 66 kA for 1 s / 66 kA for 3 s
Number of poles 4
Neutral pole current 100%
Short-circuit performance level S
Trip unit Ekip Touch LSIG
Release type Electronic
Protection functions LSIG
Long-time overload protection Yes
Short-time short-circuit protection Yes
Instantaneous short-circuit protection Yes
Earth-fault protection Yes
Installation Fixed
Terminal connection Rear flat horizontal
Current type AC
Power loss 465 W
Mechanical durability 15,000 cycles
Standard IEC 60947-2
Country of origin Italy

Frequently Asked Questions

What is the ABB 1SDA071836R1 used for?

The ABB 1SDA071836R1 is an Emax 2 air circuit breaker designed for high-current low-voltage switching and protection in industrial, commercial and infrastructure power-distribution systems.

What is the current rating of the ABB 1SDA071836R1?

The E4.2S 4000 has a rated current of 4000 A, making it suitable for large high-current electrical distribution systems.

What is the breaking capacity of the E4.2S 4000?

The breaker provides an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC.

What protection functions does the Ekip Touch LSIG provide?

The Ekip Touch LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection for comprehensive electrical system protection.

How is the ABB 1SDA071836R1 installed?

This model is a four-pole fixed air circuit breaker equipped with rear flat horizontal terminals for permanent integration into compatible low-voltage switchboards and power-distribution assemblies.

Trusted High-Performance Power Protection

ABB SACE Emax 2 air circuit breakers combine high-current switching capability with advanced electronic protection, helping industrial and infrastructure installations achieve dependable overload, short-circuit and earth-fault protection while supporting selective and efficient low-voltage power distribution.