1SDA071835R1 ABB E4.2S 4000 Ekip Touch LSI 4p FHR Air Circuit Breaker

1SDA071835R1 ABB E4.2S 4000 Ekip Touch LSI 4p FHR Air Circuit Breaker

ABB 1SDA071835R1 E4.2S 4000 Ekip Touch LSI four-pole fixed air circuit breaker with a 4000 A rated current, 690 V AC operating voltage and 85 kA breaking capacity at 400/415 V AC.

SKU: 1SDA071835R1MPN: 1SDA071835R1
Price
List Price £28,844.66 ex VAT
Your Price (ex VAT) Save 25%
£21,633.50 25% OFF
You save £7,211.17 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £21,633.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£21,633.50

Why Choose the ABB E4.2S 4000 Ekip Touch LSI 4p FHR Air Circuit Breaker?

The ABB E4.2S 4000 Ekip Touch LSI 4p FHR, order code 1SDA071835R1, is a high-performance four-pole SACE Emax 2 air circuit breaker designed for protection, switching and monitoring in demanding low-voltage electrical distribution systems. Part of the ABB SACE Emax 2 E4.2 series, this fixed circuit breaker combines a 4000 A rated uninterrupted current with the advanced Ekip Touch LSI solid-state electronic trip unit.

The E4.2S performance level provides a rated ultimate short-circuit breaking capacity of 85 kA at 400/415 V AC. Its Ekip Touch LSI electronic release provides adjustable long-time overload, selective short-time and instantaneous short-circuit protection, enabling effective coordination with upstream and downstream protective devices throughout complex power-distribution networks.

This model is a four-pole fixed air circuit breaker equipped with rear flat horizontal (FHR) terminals. With a rated operational voltage of 690 V AC, rated insulation voltage of 1000 V AC and 66 kA short-time withstand current for 1 s, the 1SDA071835R1 provides dependable high-current protection for industrial switchboards, infrastructure and critical power-distribution systems.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage power distribution.
  • 4000 A rated uninterrupted current for high-current industrial and infrastructure installations.
  • 85 kA ultimate breaking capacity at 400/415 V AC for robust short-circuit protection.
  • Ekip Touch LSI electronic trip unit provides adjustable long-time, short-time and instantaneous protection.
  • Touchscreen interface simplifies protection configuration and access to breaker information.
  • 66 kA short-time withstand current for 1 s supports demanding distribution applications.
  • Four-pole configuration supports switching and protection in four-conductor systems.
  • Fixed construction with rear flat horizontal terminals for integration into low-voltage switchboards.

Key Features

  • ABB SACE Emax 2 E4.2S series.
  • 4000 A rated uninterrupted current.
  • Four-pole configuration.
  • Ekip Touch LSI solid-state electronic trip unit.
  • Long-time overload, selective short-time and instantaneous short-circuit protection.
  • 0.4–1 × In overload protection adjustment.
  • 0.6–10 × In selective short-circuit protection adjustment.
  • 1.5–15 × In instantaneous short-circuit protection adjustment.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 85 kA Icu at 400/415 V AC.
  • 66 kA Icu at 500/525 V AC and 690 V AC.
  • 66 kA rated short-time withstand current for 1 s.
  • Fixed (F) execution with rear flat horizontal terminals.
  • Four auxiliary contacts and circuit-breaker open/closed position indication.
  • Designed in accordance with IEC 60947-2.

Advanced Protection for High-Current Power Distribution

Air circuit breakers such as the ABB E4.2S protect high-current low-voltage distribution networks against overload and short-circuit conditions while providing the switching performance required for major distribution circuits. The combination of a 4000 A current rating, 85 kA breaking capacity at 400/415 V AC and configurable LSI protection makes the 1SDA071835R1 particularly suitable for installations where selective coordination and continuity of service are important.

The Ekip Touch LSI trip unit provides configurable electronic protection through an intuitive touchscreen interface. Adjustable long-time, short-time and instantaneous functions allow protection characteristics to be coordinated with the electrical installation, helping safeguard cables, busbars, transformers and other critical equipment while reducing unnecessary disruption from electrical faults.

Typical Applications

  • Main incoming protection in low-voltage switchboards.
  • Industrial power-distribution systems.
  • Large manufacturing and process facilities.
  • Commercial and infrastructure electrical installations.
  • Data centres and critical power systems.
  • Transformer and high-current feeder protection.
  • Large electrical distribution assemblies.
  • Networks requiring selective short-circuit protection and high breaking capacity.

Technical Specifications

Series SACE Emax 2 E4.2
Order code / MPN 1SDA071835R1
EAN / GTIN 8015644756857
Product type Air circuit breaker (ACB)
Frame / performance level E4.2S
Rated uninterrupted current (Iu) 4000 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50 / 60 Hz
Number of poles 4
Trip unit Ekip Touch LSI
Release type Solid-state electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Overload protection adjustment 0.4–1 × In
Selective short-circuit protection adjustment 0.6–10 × In
Instantaneous short-circuit protection adjustment 1.5–15 × In
Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw), 1 s 66 kA
Rated short-time withstand current (Icw), 3 s 66 kA
Execution Fixed
Main terminals Rear flat horizontal (FHR)
Terminal connection Bolted
Auxiliary contacts 4
Circuit-breaker position indication Open / closed
Suitable for IT networks Yes, up to 690 V
Power loss 465 W
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071835R1 used for?

The ABB 1SDA071835R1 is an Emax 2 air circuit breaker designed for protection and switching of high-current low-voltage power-distribution systems in industrial, commercial and infrastructure installations.

What is the current rating of the ABB E4.2S 4000?

This E4.2S air circuit breaker has a rated uninterrupted current of 4000 A.

What protection does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI electronic trip unit provides adjustable long-time overload, selective short-time and instantaneous short-circuit protection.

What is the breaking capacity of the ABB 1SDA071835R1?

The E4.2S 4000 has a rated ultimate short-circuit breaking capacity of 85 kA at 400/415 V AC and 66 kA at 500/525 V AC and 690 V AC.

Is the ABB 1SDA071835R1 fixed or withdrawable?

The 1SDA071835R1 is a fixed four-pole air circuit breaker equipped with rear flat horizontal terminals, four auxiliary contacts and circuit-breaker open/closed position indication.

Trusted Protection for High-Current Power Systems

ABB SACE Emax 2 air circuit breakers combine high-current switching performance, advanced electronic protection and flexible system integration to provide dependable protection for demanding industrial, commercial and infrastructure power-distribution systems.