1SDA071801R1 ABB E4.2V 3200 Ekip Dip LI 4p F HR Air Circuit Breaker 3200 A

1SDA071801R1 ABB E4.2V 3200 Ekip Dip LI 4p F HR Air Circuit Breaker 3200 A

ABB 1SDA071801R1 SACE Emax 2 E4.2V 3200 Ekip Dip LI four-pole fixed air circuit breaker rated at 3200 A and 690 V AC with 150 kA breaking capacity at 400 V AC and electronic long-time and instantaneous protection.

SKU: 1SDA071801R1MPN: 1SDA071801R1
Price
List Price £24,517.98 ex VAT
Your Price (ex VAT) Save 25%
£18,388.49 25% OFF
You save £6,129.50 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £18,388.49
Trade pricing is personalised to your account

Manufacturer Lead Time

£18,388.49

Why Choose the ABB E4.2V 3200 Ekip Dip LI 4p F HR Air Circuit Breaker?

The ABB E4.2V 3200 Ekip Dip LI 4p F HR, order code 1SDA071801R1, is a high-performance four-pole air circuit breaker (ACB) designed for protection and switching in demanding low-voltage power distribution systems. Part of the ABB SACE Emax 2 series, it combines a 3200 A rated uninterrupted current with the Ekip Dip LI electronic protection release and the exceptional short-circuit performance of the E4.2V frame.

This fixed circuit breaker incorporates the Ekip Dip LI solid-state electronic trip unit, providing long-time overload and instantaneous short-circuit protection. The LI protection configuration provides dependable protection for high-current distribution circuits while maintaining straightforward electronic adjustment for coordination with cables, busbars, switchgear and connected electrical equipment.

Rated for operation at up to 690 V AC, the E4.2V 3200 provides an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC and 100 kA at 690 V AC. It also provides a 100 kA short-time withstand current for 1 s. This version features a fixed four-pole construction with rear flat horizontal terminals, making it suitable for high-capacity industrial, commercial and infrastructure switchboards.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage distribution systems.
  • 3200 A rated uninterrupted current for high-current electrical installations.
  • Four-pole configuration with a neutral pole rated at 100% of Iu.
  • Ekip Dip LI electronic trip unit with long-time overload and instantaneous short-circuit protection.
  • 150 kA ultimate short-circuit breaking capacity at 400–440 V AC for systems with exceptionally high prospective fault currents.
  • 100 kA ultimate short-circuit breaking capacity at 690 V AC.
  • 100 kA short-time withstand current for 1 s for high-capacity power distribution applications.
  • Fixed configuration with rear flat horizontal terminals for switchboard integration.

Key Features

  • ABB SACE Emax 2 E4.2V series.
  • 3200 A rated uninterrupted current.
  • Four-pole construction.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • V high-performance breaking-capacity class.
  • 150 kA Icu at 400–440 V AC.
  • 100 kA Icu at 690 V AC.
  • 100% Ics/Icu ratio.
  • 100 kA short-time withstand current for 1 s.
  • Ekip Dip LI solid-state electronic protection release.
  • Long-time overload and instantaneous short-circuit protection functions.
  • Overload release setting of 1280 A.
  • Undelayed short-circuit release setting of 4800 A.
  • Four auxiliary changeover contacts.
  • Open/closed circuit-breaker position indication.
  • Fixed circuit-breaker construction with rear flat horizontal terminals.
  • Optional motor operating mechanism compatibility.

High-Performance LI Protection for Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 protect high-current low-voltage distribution circuits against potentially damaging overload and short-circuit conditions. The E4.2V frame provides exceptional fault-interruption performance, helping protect cables, busbars, switchgear and connected electrical equipment in large industrial and infrastructure power distribution systems.

The Ekip Dip LI electronic trip unit provides long-time overload and instantaneous short-circuit protection for straightforward and dependable circuit protection. Combined with the E4.2V frame's 150 kA Icu at 400–440 V AC, 100 kA Icu at 690 V AC and 100 kA Icw for 1 s, the 1SDA071801R1 is particularly suited to main switchboards and high-current distribution circuits where exceptional fault interruption capability is required.

Typical Applications

  • Main low-voltage electrical distribution switchboards.
  • High-fault-level industrial power distribution systems.
  • Manufacturing and process facilities.
  • Large commercial buildings and infrastructure installations.
  • High-current feeder and distribution circuits.
  • Transformer-fed low-voltage distribution systems.
  • Critical power and utility distribution installations.
  • Electrical switchgear and high-capacity power distribution assemblies.

Technical Specifications

Range SACE Emax 2
Series E4.2V
ABB order code 1SDA071801R1
EAN 8015644756512
Product type Air circuit breaker
Rated uninterrupted current (Iu) 3200 A
Rated current (In) 3200 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Number of poles 4
Neutral pole current 100% of Iu
Short-circuit performance level V
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 100 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 100 kA
Service short-circuit breaking capacity (Ics) at 400 V AC 150 kA
Service short-circuit breaking capacity (Ics) at 690 V AC 100 kA
Ics as percentage of Icu 100%
Short-time withstand current (Icw) 100 kA for 1 s; 75 kA for 3 s
Trip unit Ekip Dip LI
Release type Electronic
Protection functions Long-time (L) and instantaneous (I)
Overload release current setting 1280 A
Undelayed short-circuit release setting 4800 A
Integrated earth-fault protection No
Mounting type Fixed
Terminal type Rear flat horizontal
Main circuit connection Bolt connection
Auxiliary contacts 4 changeover contacts
Motor drive Optional
Degree of protection IP30
Power loss 425 W
Mechanical durability 20,000 operating cycles
Electrical durability 7000 operating cycles at up to 690 V AC
Dimensions (W × H × D) 510 × 371 × 270 mm
Net weight 70 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071801R1 used for?

The ABB 1SDA071801R1 is a four-pole air circuit breaker used for switching and protecting high-current low-voltage power distribution circuits against overload and short-circuit conditions, particularly where high prospective fault currents are present.

What is the rated current of the ABB 1SDA071801R1?

The E4.2V 3200 Ekip Dip LI 4p F HR has a rated uninterrupted current of 3200 A and a rated operational voltage of 690 V AC.

What is the short-circuit breaking capacity of the ABB 1SDA071801R1?

The E4.2V provides an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC and 100 kA at 690 V AC, with a short-time withstand current of 100 kA for 1 s.

What protection functions does the Ekip Dip LI trip unit provide?

The Ekip Dip LI electronic trip unit provides long-time overload (L) and instantaneous short-circuit (I) protection. This LI configuration does not include integrated earth-fault protection.

How is the ABB 1SDA071801R1 installed?

This model is a fixed four-pole circuit breaker with rear flat horizontal terminals and bolt-connected main terminals, designed for installation within compatible low-voltage switchboards and high-capacity power distribution assemblies.

Trusted Power Protection from ABB

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection with exceptional short-circuit performance, providing dependable switching and circuit protection for demanding industrial, commercial and infrastructure power distribution systems.