1SDA071788R1 ABB E4.2S 3200 Ekip Hi-Touch LSI 4p F HR Air Circuit Breaker 3200 A

1SDA071788R1 ABB E4.2S 3200 Ekip Hi-Touch LSI 4p F HR Air Circuit Breaker 3200 A

ABB 1SDA071788R1 E4.2S 3200 Ekip Hi-Touch LSI 4p F HR is a 3200 A four-pole fixed SACE Emax 2 air circuit breaker with Ekip Hi-Touch LSI electronic protection, up to 85 kA short-circuit breaking capacity and rear flat horizontal terminals.

SKU: 1SDA071788R1MPN: 1SDA071788R1
Price
List Price £23,426.55 ex VAT
Your Price (ex VAT) Save 25%
£17,569.91 25% OFF
You save £5,856.64 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £17,569.91
Trade pricing is personalised to your account

Manufacturer Lead Time

£17,569.91

Why Choose the ABB E4.2S 3200 Ekip Hi-Touch LSI 4p F HR Air Circuit Breaker?

The ABB E4.2S 3200 Ekip Hi-Touch LSI 4p F HR, order code 1SDA071788R1, is a high-current four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range. Designed for demanding low-voltage power distribution systems, it combines a 3200 A rated uninterrupted current with the advanced Ekip Hi-Touch LSI solid-state electronic release for long-time overload, selective short-time and instantaneous short-circuit protection.

The Ekip Hi-Touch LSI release provides advanced electronic protection, measurement and system-management capabilities for sophisticated electrical installations. Its LSI protection functions enable coordinated overload and short-circuit protection, while the Hi-Touch platform provides an enhanced interface and expanded functionality for monitoring and managing critical power-distribution circuits.

The E4.2S performance level provides a rated ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC, together with a rated short-time withstand current of 66 kA for 1 s. Fixed four-pole construction, rear flat horizontal terminals and four auxiliary contacts make the 1SDA071788R1 well suited to high-current industrial and commercial switchboards.

Key Advantages

  • High-current ABB SACE Emax 2 air circuit breaker for demanding low-voltage distribution systems.
  • 3200 A rated uninterrupted current for substantial industrial and commercial electrical loads.
  • Four-pole configuration for switching and protection of three phases and neutral.
  • Advanced Ekip Hi-Touch LSI electronic trip unit for sophisticated protection and power-management applications.
  • Provides long-time, selective short-time and instantaneous short-circuit protection.
  • 85 kA Icu at 400–440 V AC for installations with high prospective short-circuit currents.
  • 66 kA Icu at 500–690 V AC maintains substantial breaking performance at higher system voltages.
  • 66 kA Icw for 1 s supports selective protection coordination.
  • Fixed construction with rear flat horizontal terminals for permanent switchboard integration.

Key Features

  • ABB SACE Emax 2 E4.2S series.
  • 3200 A rated uninterrupted current.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Four-pole fixed air circuit breaker.
  • Ekip Hi-Touch LSI solid-state electronic release.
  • Long-time overload protection.
  • Selective short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • 85 kA Icu at 400–440 V AC.
  • 66 kA Icu at 500–690 V AC.
  • 66 kA Icw for 1 s and 3 s.
  • S short-circuit performance level.
  • Rear flat horizontal main terminals.
  • Bolted main-circuit connections.
  • Four auxiliary contacts.
  • Circuit-breaker open/closed position indication.

Advanced High-Current Protection for Power Distribution

ABB SACE Emax 2 air circuit breakers provide switching, isolation and electronic protection for high-current low-voltage distribution circuits. With its 3200 A current rating, breaking capacity of up to 85 kA and 66 kA short-time withstand capability, the E4.2S 3200 is designed for substantial incoming supplies and distribution feeders where dependable fault interruption and system selectivity are essential.

The Ekip Hi-Touch LSI release combines long-time overload, selective short-time and instantaneous short-circuit protection with ABB's advanced Hi-Touch electronic platform. This makes the breaker particularly suitable for sophisticated electrical networks where protection coordination, power monitoring and integration with wider energy-management strategies are important design requirements.

Typical Applications

  • High-current low-voltage main distribution switchboards.
  • Industrial incoming supply circuits.
  • Manufacturing and process plants.
  • Large commercial building power distribution.
  • Data centre and critical-power distribution systems.
  • Transformer secondary protection.
  • High-current outgoing distribution feeders.
  • Infrastructure and utility installations.
  • Power systems requiring advanced monitoring and selective short-circuit coordination.

Technical Specifications

Series SACE Emax 2
ABB product group Emax2 Air Circuit Breaker
Frame / type E4.2S
Order code 1SDA071788R1
EAN / GTIN 8015644756383
Product type Air circuit breaker
Rated uninterrupted current (Iu) 3200 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Number of poles 4
Release Ekip Hi-Touch LSI
Release type Solid-state electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Integrated earth-fault protection No
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Rated service short-circuit breaking capacity (Ics) 85 kA at 380–440 V AC / 66 kA at 500–690 V AC
Rated short-time withstand current (Icw) 66 kA for 1 s / 66 kA for 3 s
Short-circuit performance level S
Version Fixed (F)
Terminal connection Rear flat horizontal (HR)
Terminal type Bolt
Main-circuit screw size M12
Main-circuit tightening torque 70 N·m
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Dimensions (W × H × D) 515 × 371 × 270 mm
Net weight 70 kg
Country of origin Italy
Reference standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071788R1 used for?

The ABB 1SDA071788R1 is a 3200 A four-pole air circuit breaker designed for switching and protecting high-current low-voltage distribution circuits where advanced Ekip Hi-Touch LSI protection and selective short-circuit coordination are required.

What is the current rating of the E4.2S 3200 Ekip Hi-Touch LSI?

The breaker has a rated uninterrupted current of 3200 A and a rated operational voltage of up to 690 V AC.

What protection does the Ekip Hi-Touch LSI release provide?

The Ekip Hi-Touch LSI solid-state electronic release provides long-time overload, selective short-time short-circuit and instantaneous short-circuit protection, together with the advanced monitoring and management capabilities of ABB's Hi-Touch platform.

What is the breaking capacity of the ABB E4.2S 3200?

The E4.2S 3200 provides a rated ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC, with a rated short-time withstand current of 66 kA for 1 s and 3 s.

Is the ABB 1SDA071788R1 fixed or withdrawable?

The 1SDA071788R1 is a fixed four-pole air circuit breaker with rear flat horizontal terminals and bolted main-circuit connections for permanent installation within a low-voltage switchboard.

Trusted Advanced Power Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high-current switching, advanced electronic protection and strong short-circuit performance to provide dependable protection, monitoring and selective coordination for demanding low-voltage electrical distribution systems.