1SDA071785R1 ABB E4.2S 3200 Ekip Touch LSI 4p F HR Air Circuit Breaker 3200 A

1SDA071785R1 ABB E4.2S 3200 Ekip Touch LSI 4p F HR Air Circuit Breaker 3200 A

ABB 1SDA071785R1 SACE Emax 2 E4.2S 3200 Ekip Touch LSI four-pole fixed air circuit breaker rated at 3200 A and 690 V AC with 85 kA breaking capacity at 400/415 V AC and electronic long-time, short-time and instantaneous protection.

SKU: 1SDA071785R1MPN: 1SDA071785R1
Price
List Price £19,879.41 ex VAT
Your Price (ex VAT) Save 25%
£14,909.56 25% OFF
You save £4,969.85 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £14,909.56
Trade pricing is personalised to your account

Manufacturer Lead Time

£14,909.56

Why Choose the ABB E4.2S 3200 Ekip Touch LSI 4p F HR Air Circuit Breaker?

The ABB E4.2S 3200 Ekip Touch LSI 4p F HR, order code 1SDA071785R1, is a high-performance four-pole air circuit breaker (ACB) designed for protection and switching in demanding low-voltage power distribution systems. Part of the ABB SACE Emax 2 series, it combines a 3200 A rated current with the advanced Ekip Touch LSI electronic protection release and robust short-circuit performance.

This fixed circuit breaker incorporates the Ekip Touch LSI solid-state electronic trip unit, providing long-time overload, short-time selective short-circuit and instantaneous short-circuit protection. Adjustable electronic protection settings support effective coordination throughout complex distribution networks, while the Ekip Touch interface provides convenient configuration and monitoring of the breaker.

Rated for operation at up to 690 V AC, the E4.2S 3200 provides an 85 kA ultimate short-circuit breaking capacity at 400/415 V AC and 66 kA at 690 V AC. This version features a fixed four-pole construction with rear horizontal terminals and four auxiliary contacts, making it suitable for high-current industrial, commercial and infrastructure distribution assemblies.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage distribution systems.
  • 3200 A rated current for high-current electrical installations.
  • Four-pole configuration for switching and protection of three phases and neutral.
  • Advanced Ekip Touch LSI electronic trip unit with long-time, short-time and instantaneous protection.
  • 85 kA Icu at 400/415 V AC for dependable interruption of high prospective fault currents.
  • 66 kA Icu at 690 V AC for demanding higher-voltage low-voltage distribution networks.
  • Adjustable protection settings support selective coordination throughout the electrical system.
  • Fixed configuration with rear horizontal terminals for switchboard integration.

Key Features

  • ABB SACE Emax 2 E4.2S series.
  • 3200 A rated current.
  • Four-pole construction.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 50/60 Hz operating frequency.
  • S short-circuit performance level.
  • 85 kA Icu at 400/415 V AC.
  • 85 kA Icu at 440 V AC.
  • 66 kA Icu at 690 V AC.
  • 66 kA short-time withstand current for 1 s.
  • Ekip Touch LSI solid-state electronic protection release.
  • Long-time overload, short-time selective and instantaneous short-circuit protection functions.
  • Overload protection adjustable from 0.4–1 × In.
  • Instantaneous protection adjustable from 1.5–15 × In.
  • Touch-sensitive display for protection configuration.
  • Four auxiliary contacts with open/closed circuit-breaker position indication.
  • Fixed circuit-breaker construction with rear horizontal terminals.

Advanced LSI Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 protect high-current low-voltage distribution circuits against potentially damaging overload and short-circuit conditions. The E4.2S frame combines substantial current-carrying capability with high fault-interruption performance, helping protect cables, busbars, switchgear and connected electrical equipment in large power distribution systems.

The Ekip Touch LSI electronic trip unit combines long-time overload, short-time selective and instantaneous short-circuit protection, allowing protection settings to be coordinated with upstream and downstream devices. With a 3200 A current rating, 85 kA Icu at 400/415 V AC and 66 kA Icu at 690 V AC, the 1SDA071785R1 is particularly suited to main switchboards and high-current distribution circuits requiring configurable electronic protection and dependable fault interruption.

Typical Applications

  • Main low-voltage electrical distribution switchboards.
  • Industrial power distribution systems.
  • Manufacturing and process facilities.
  • Large commercial buildings and infrastructure installations.
  • High-current feeder and distribution circuits.
  • Transformer-fed low-voltage distribution systems.
  • Critical power distribution installations.
  • Electrical switchgear and high-capacity power distribution assemblies.

Technical Specifications

Range SACE Emax 2
Series E4.2S
ABB order code 1SDA071785R1
EAN 8015644756352
Product type Air circuit breaker
Rated current 3200 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50/60 Hz
Number of poles 4
Short-circuit performance level S
Ultimate short-circuit breaking capacity (Icu) at 380 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 500/525 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Short-time withstand current (Icw) 66 kA for 1 s
Trip unit Ekip Touch LSI
Release type Solid-state electronic
Protection functions Long-time (L), short-time (S) and instantaneous (I)
Overload protection adjustment 0.4–1 × In
Instantaneous protection adjustment 1.5–15 × In
Integrated earth-fault protection No
Mounting type Fixed
Terminal position Rear horizontal
Auxiliary contacts 4
Power loss 425 W
Dimensions 510 × 371 × 270 mm
Standard IEC 60947-2
Country of origin Italy

Frequently Asked Questions

What is the ABB 1SDA071785R1 used for?

The ABB 1SDA071785R1 is a four-pole air circuit breaker used for switching and protecting high-current low-voltage power distribution circuits against overload and short-circuit conditions.

What is the rated current of the ABB 1SDA071785R1?

The E4.2S 3200 Ekip Touch LSI 4p F HR has a rated current of 3200 A and a rated operational voltage of up to 690 V AC.

What is the short-circuit breaking capacity of the ABB 1SDA071785R1?

The E4.2S provides an ultimate short-circuit breaking capacity of 85 kA at 400/415 V AC and 66 kA at 690 V AC, with a short-time withstand current of 66 kA for 1 s.

What protection functions does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI electronic trip unit provides long-time overload (L), short-time selective short-circuit (S) and instantaneous short-circuit (I) protection. This LSI configuration does not include integrated earth-fault protection.

How is the ABB 1SDA071785R1 installed?

This model is a fixed four-pole circuit breaker with rear horizontal terminals, designed for installation within compatible low-voltage switchboards and high-capacity power distribution assemblies.

Trusted Power Protection from ABB

ABB SACE Emax 2 air circuit breakers combine advanced Ekip electronic protection with robust switching and fault-interruption performance, providing dependable protection and control for demanding industrial, commercial and infrastructure power distribution systems.