ABB 1SDA071784R1 SACE Emax 2 E4.2S 3200 Ekip Touch LI four-pole fixed air circuit breaker rated at 3200 A and 690 V AC with 85 kA breaking capacity at 400 V AC and electronic long-time and instantaneous protection.
£14,588.00
The ABB E4.2S 3200 Ekip Touch LI 4p F HR, order code 1SDA071784R1, is a high-performance four-pole air circuit breaker (ACB) designed for protection and switching in demanding low-voltage power distribution systems. Part of the ABB SACE Emax 2 series, it combines a 3200 A rated uninterrupted current with the advanced Ekip Touch LI electronic protection release and the robust short-circuit performance of the E4.2S frame.
This fixed circuit breaker incorporates the Ekip Touch LI electronic trip unit, providing long-time overload and instantaneous short-circuit protection. The Ekip Touch platform combines configurable electronic protection with an intuitive interface and advanced measurement capabilities, making it well suited to modern switchboards where reliable circuit protection and visibility of electrical operating conditions are required.
The E4.2S 3200 is rated for operation at up to 690 V AC and provides an 85 kA ultimate short-circuit breaking capacity at 400 V AC. This version features a fixed four-pole construction with rear flat horizontal terminals and is fitted with four auxiliary changeover contacts, making it suitable for high-current industrial, commercial and infrastructure distribution assemblies.
Air circuit breakers such as the ABB SACE Emax 2 protect high-current low-voltage distribution circuits against potentially damaging overload and short-circuit conditions. The E4.2S frame provides substantial current-carrying and fault-interruption capability, helping protect cables, busbars, switchgear and connected electrical equipment in large power distribution systems.
The Ekip Touch LI electronic trip unit combines long-time overload and instantaneous short-circuit protection with the advanced interface and monitoring capabilities of ABB's Ekip Touch platform. With a 3200 A current rating and 85 kA Icu at 400 V AC, the 1SDA071784R1 is particularly suited to main switchboards and high-current distribution circuits where dependable protection, configurable settings and straightforward system monitoring are required.
| Range | SACE Emax 2 |
|---|---|
| Series | E4.2S |
| ABB order code | 1SDA071784R1 |
| EAN | 8015644756345 |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 3200 A |
| Rated operational voltage | 690 V AC |
| Number of poles | 4 |
| Neutral pole current | 100% of Iu |
| Short-circuit performance level | S |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 85 kA |
| Trip unit | Ekip Touch LI |
| Release type | Solid-state electronic |
| Protection functions | Long-time (L) and instantaneous (I) |
| Overload release setting | 1280–3200 A |
| Instantaneous short-circuit release setting | 4800–48000 A |
| Integrated earth-fault protection | No |
| Mounting type | Fixed |
| Terminal type | Rear flat horizontal |
| Auxiliary contacts | 4 changeover contacts |
| Motor drive | Optional |
| Mechanical durability | 20,000 operating cycles |
| Electrical durability | 7000 operating cycles at up to 690 V AC |
| Power loss | 425 W |
| Depth | 270 mm |
| Width | 510 mm |
| Standard | IEC |
| Country of origin | Italy |
The ABB 1SDA071784R1 is a four-pole air circuit breaker used for switching and protecting high-current low-voltage power distribution circuits against overload and short-circuit conditions.
The E4.2S 3200 Ekip Touch LI 4p F HR has a rated uninterrupted current of 3200 A and is rated for operation at up to 690 V AC.
The E4.2S performance level provides an ultimate short-circuit breaking capacity of 85 kA at 400 V AC.
The Ekip Touch LI electronic trip unit provides long-time overload (L) and instantaneous short-circuit (I) protection. This LI configuration does not include integrated earth-fault protection.
This model is a fixed four-pole circuit breaker with rear flat horizontal terminals, designed for installation within compatible low-voltage switchboards and high-capacity power distribution assemblies.
ABB SACE Emax 2 air circuit breakers combine advanced Ekip electronic protection with robust switching and fault-interruption performance, providing dependable protection and control for demanding industrial, commercial and infrastructure power distribution systems.