ABB 1SDA071782R1 Emax 2 E4.2S 3200 Ekip Dip LSI four-pole fixed air circuit breaker rated at 3200 A and 690 V AC with 85 kA breaking capacity for high-current low-voltage power distribution and circuit protection.
£14,851.12
The ABB 1SDA071782R1 is a high-performance Emax 2 air circuit breaker (ACB) designed for protection, switching and isolation in demanding low-voltage electrical distribution systems. Identified as the E4.2S 3200 Ekip Dip LSI 4p FHR, this four-pole fixed circuit breaker combines a 3200 A rated current with ABB’s Ekip Dip LSI solid-state electronic trip unit for dependable circuit protection.
As part of the ABB SACE Emax 2 series, the E4.2S provides high short-circuit performance together with configurable electronic protection. The Ekip Dip LSI release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection, enabling effective coordination and selectivity within industrial and commercial power-distribution installations.
With a rated operational voltage of up to 690 V AC and an ultimate short-circuit breaking capacity of 85 kA at 400–415 V AC, the 1SDA071782R1 is suitable for high-current installations where dependable fault interruption is essential. Its fixed four-pole construction and rear horizontal terminals provide a practical configuration for integration into low-voltage switchboards and distribution assemblies.
Air circuit breakers such as the ABB Emax 2 E4.2S provide switching, isolation and protection for high-current low-voltage electrical systems. The E4.2S performance level combines a 3200 A current rating with substantial short-circuit interruption capability, making it suitable for main distribution and other critical positions within industrial switchboards.
The Ekip Dip LSI electronic trip unit provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. Adjustable protection settings allow the breaker to be coordinated with other protective devices within an electrical installation, helping maintain selectivity while protecting cables, busbars, transformers and connected equipment against damaging overcurrents.
| Product group | Emax 2 Air Circuit Breaker |
|---|---|
| Range | SACE Emax 2 |
| Series | E4.2S |
| ABB order code / MPN | 1SDA071782R1 |
| Product type | Air circuit breaker |
| Rated current | 3200 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage | 1000 V AC |
| Rated impulse withstand voltage | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC | 85 kA |
| Rated short-time withstand current (Icw) | 66 kA for 1 s |
| Number of poles | 4 |
| Neutral pole current | 100% |
| Short-circuit performance level | S |
| Trip unit | Ekip Dip LSI |
| Release type | Solid-state electronic |
| Protection functions | LSI |
| Overload release adjustment range | 1280–3200 A |
| Short-time delayed short-circuit adjustment range | 1920–32000 A |
| Instantaneous short-circuit adjustment range | 4800–48000 A |
| Integrated earth-fault protection | No |
| Installation | Fixed |
| Terminal connection | Rear horizontal |
| Current type | AC |
| Auxiliary contacts | 4 change-over contacts |
| Protection rating | IP30 |
| Electrical durability | 7000 cycles |
| Mechanical durability | 20,000 cycles |
| Power loss | 425 W |
| Dimensions (H × W × D) | 371 × 510 × 270 mm |
| Weight | 70 kg |
| EAN | 8015644756321 |
The ABB 1SDA071782R1 is an Emax 2 air circuit breaker designed for high-current low-voltage switching and circuit protection in industrial, commercial and infrastructure power-distribution systems.
The E4.2S 3200 has a rated current of 3200 A, making it suitable for demanding high-current electrical distribution applications.
The E4.2S version provides an ultimate short-circuit breaking capacity of 85 kA at 400–415 V AC.
The Ekip Dip LSI electronic trip unit provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. This LSI version does not include integrated earth-fault protection.
This model is a four-pole fixed air circuit breaker equipped with rear horizontal terminals for permanent integration into compatible low-voltage switchboards and power-distribution assemblies.
ABB SACE Emax 2 air circuit breakers provide dependable high-current switching and electronic circuit protection for demanding low-voltage installations, helping industrial and infrastructure systems achieve effective fault protection, selectivity and continuity of service.